• Title/Summary/Keyword: Type C tank

Search Result 162, Processing Time 0.025 seconds

Cooling Tower Overhaul of Secondary Cooling System in HANARO (하나로 2 차 냉각탑의 공장분해수리)

  • Park, Young-Chul;Lee, Young-Sub;Kim, Yang-Gon;Jung, Hoan-Sung;Lim, In-Chul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2714-2719
    • /
    • 2007
  • HANARO, an open-tank-in-pool type research reactor of 30 MWth power in Korea, has been operating normally since its initial criticality in February, 1995. For the last about ten years, A cooling tower of a secondary cooling system has been operated normally in HANARO. Last year, the cooling tower has been overhauled for preservative maintenance including fills, eliminators, wood support, water distribution system, motors, driving shafts, gear reducers, basements, blades and etc. This paper describes the results of the overhaul. As results, it is confirmed that the cooling tower maintains a good operability through a filed test. And a cooling capability will be tested when a wet bulb temperature is maintained about 28 $^{\circ}C$ in summer and the reactor is operated with the full power.

  • PDF

The Effect of Plastic Working on the Membrane Fatigue Life (소성가공이 멤브레인 피로 수명에 미치는 영향)

  • Yoon I.S.;Kim Y.K.;Kim J.K.
    • 한국가스학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.193-198
    • /
    • 2005
  • An investigation was made on the fatigue characteristics of type 304 stainless steel membrane manufactured by plastic working. To investigate the effect of plastic deformation, tests were performed with 5 types of specimens having different amount of plastic deformation. Fatigue tests were executed under both room and LNG temperatures ($-162^{\circ}C$). All the test results were compared with the fatigue data provided by RPIS(Recommended Practice for Inground LNG Storage Tank). On the basis of these results, it was confirmed that RPIS's design fatigue curve could be applied to evaluate fatigue lift of KOGAS membrane manufactured by pressing.

  • PDF

The Analysis of Flow Distribution in the Core Channel of the HANARO Flow Simulated Test Facility (하나로 유동모의 시험설비의 노심채널 유동분포 해석)

  • Park Y C.;Kim K. R.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.151-154
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulated test facility has been developed for the verification of structural integrity of those experimental facilities prior to loading In the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The half-core structure assembly is composed of plenum, grid plate, core channel with flow tubes, chimney and dummy pool. The flow channels are to be filled with flow orifices to simulate similar flow characteristics to the HANARO. This paper describes an analysis of the flow distribution of the cote channel and compares with the test results. As results, the analysis showed similar flow characteristics compared with those in the test results.

  • PDF

Development of Automatical Soybean Sprouting Equipment for Medium Amount Production by Using Multiple Siphons (복수 싸이펀을 이용한 중량생산용 콩나물 자동재배기 개발)

  • 김만중;백승화;최용배;김형욱
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.4
    • /
    • pp.886-889
    • /
    • 1999
  • To develope the soybean sprouting equipment(a type of cabinet) for medium amount(one bucket; 10~13kg) production of soybean sprouts, the watering system was made of four siphons and four the bottle necked water tank. Diameter of four siphons used for development of the watering system were 8, 13, 17 and 21mm, respectively and their water exhausting volumes were 40, 92, 154, 524ml/sec, respectively. The watering system can be automatically watered 524ml/sec without electric supply. The soybean sprouting equipment is consisted of four the bottle necked water tanks with the four siphons and six sprouting buckets with net shaped bottom for water draining. The soybean sprouting equipment with the watering system may be produced more than one box a day in the condition of 6~7 watering times a day at 25~30oC.

  • PDF

Stress Analysis of Pressurization Type Propellant Tank in the Satellite (인공위성용 능동가압형 추진제 탱크의 응력 해석)

  • 한근조;심재준;최진철
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.21-21
    • /
    • 1997
  • 인공위성용 추진제 탱크를 개발하기 위해 여러 설계인자를 설정하여 각 인자가 탱크벽면에 미치는 응력분포 영향을 구하고, 또한 최적의 인자 값을 구하기 위해 각 인자의 변화에 따라서 구조해석을 수행하였다. 탱크 지지부 위치와 탱크 벽면 두께 변화에 따른 탱크 벽면에 미치는 응력분포 영향을 고찰하기 위해 1/4 모델을 설정하였고, 연료배출구의 위치변화(경사각돈)에 따른 응력분포는 1/2 모델을 설정하여 해석을 하였다. 탱크에 작용하는 하중은 연료압력에 의해 발생하는 정하중(350 psi)을 가하며 또한, 발사 시 발사체로부터 전달되는 최대동하중(llg)을 고려하였다. 그리고, 탱크가 인공위성에 장착될 때에 발생하는 다양한 장착조건에 대해서 구조해석을 수행하였고, 추진제 배출구 각도가 $0^{\circ}$ 에서 $25^{\circ}C$까지 변화할 때 탱크 벽면에 미치는 응력분포 영향을 구했다. 그래서 각 조건에서 구한 상당응력분포와 인자의 최적 값은 추진제 탱크를 설계하기 위한 기초적인 자료로 활용하고자 한다.

  • PDF

Establishment of the Procedure to Prevent Boron Precipitation During Post-LOCA Long Term Cooling for WH 3-Loop NPPs

  • Cho, H.R.;Lee, S.K.;Ban, C.H.;Hwang, S.T.;Chang, B.H.
    • Nuclear Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.47-57
    • /
    • 1998
  • Boric acid concentrations of the refueling water storage tank and the accumulators for Westinghouse 3-loop type plants are increased to meet the post loss of coolant accident shutdown requirement for the extended fuel cycles from 12 months to 18 months. To maintain long term cooling capability following a LOCA, the switchover time is examined using BORON code to prevent the boron precipitation in the reactor core with the increased boron concentrations. The analysis results show that hot leg recirculation switchover times are shortened to 7.5 hours from 24 hours after the initiation of LOCA for Kori 3&4 and 8 hours from 18 hours for Ulchin 1&2, respectively. The How path in the mode J for Kori 3&4 is recommended to realign to the simultaneous recirculation of both hot and cold legs from the cold leg recirculation, as done by Ulchin 1&2.

  • PDF

Heating Performance of Horizontal Geothermal Heat Pump System for Protected Horticulture (시설원예용 수평형 지열히트펌프의 난방 성능 해석)

  • Kang, Youn-Ku;Ryou, Young-Sun;Kang, Geum-Choon;Paek, Yee;Kim, Young-Joong
    • Journal of Biosystems Engineering
    • /
    • v.32 no.1 s.120
    • /
    • pp.30-36
    • /
    • 2007
  • Geothermal heat pump systems use the earth as a heat source in heating mode and a heat sink in cooling mode. These systems can be used for heating or cooling systems in farm facilities such as greenhouses for protected horticulture, cattle sheds, mushroom house, etc. A horizontal type means that a geothermal heat exchanger is laid in the trench buried in 1.2 to 1.8 m depth. Because a horizontal type has advantages of low installation, operation and maintenance costs compared to a vertical type, it is easy to be adopted to agriculture. In this study, to heat and cool farm facilities and obtain basic data for practical application of horizontal geothermal heat pump systems in agriculture, a horizontal geothermal heat pump system of 10 RT scale was installed in greenhouse. Heating performance of this system was estimated. The horizontal geothermal heat pump used in this study had heating COP of 4.57 at soil temperature of 14$^{\circ}C$ for depth of 1.75m and heating COP of 3.75 at soil temperature of 7$^{\circ}C$ for the same depth. The stratification of water temperature in heat tank appeared during the whole heat rejection period.

A Study on the Characteristic of Motion and Resistance Performance from the Body Plan of Planning Leisure boat at low speed (저속시 활주형 레저보트의 단면형상에 따른 저항·내항성능 특성연구)

  • Park, C.H.;An, N.H.;Jang, H.Y.;Kwon, Y.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.17-23
    • /
    • 2012
  • In this study, the numerical simulation and basin model test have been performed to evaluate sea worthiness and resistance performance for a small pre-planning three type of leisure boats which are U, V, Y shapes of hull forms. As a well known commercial CFD code, Maxsurf, was applied for modeling hull forms used as the solver of motion analysis. Also the model resistance test was carried out to estimate the effective power of boat in the basin tank. Numerical simulation and model test results show that Y-shaped hull is better than the other types in terms of heave and pitch motion, having a key effect on a boat sea worthiness. But V-type hull is more efficiency than others cases in resistance performance.

Induction of pro-inflammatory cytokines by 29-kDa FN-f via cGAS/STING pathway

  • Hwang, Hyun Sook;Lee, Mi Hyun;Choi, Min Ha;Kim, Hyun Ah
    • BMB Reports
    • /
    • v.52 no.5
    • /
    • pp.336-341
    • /
    • 2019
  • The cGAS-STING pathway plays an important role in pathogen-induced activation of the innate immune response. The 29-kDa amino-terminal fibronectin fragment (29-kDa FN-f) found predominantly in the synovial fluid of osteoarthritis (OA) patients increases the expression of catabolic factors via the toll-like receptor-2 (TLR-2) signaling pathway. In this study, we investigated whether 29-kDa FN-f induces inflammatory responses via the cyclic GMP-AMP synthase (cGAS)/stimulator of interferon gene (STING) pathway in human primary chondrocytes. The levels of cGAS and STING were elevated in OA cartilage compared with normal cartilage. Long-term treatment of chondrocytes with 29-kDa FN-f activated the cGAS/STING pathway together with the increased level of gamma-H2AX, a marker of DNA breaks. In addition, the expression of pro-inflammatory cytokines, including granulocyte-macrophage colony-stimulating factor (GM-CSF/CSF-2), granulocyte colony-stimulating factor (G-CSF/CSF-3), and type I interferon ($IFN-{\alpha}$), was increased more than 100-fold in 29-kDa FN-f-treated chondrocytes. However, knockdown of cGAS and STING suppressed 29-kDa FN-f-induced expression of GM-CSF, G-CSF, and $IFN-{\alpha}$ together with the decreased activation of TANK-binding kinase 1 (TBK1), interferon regulatory factor 3 (IRF3), and inhibitor protein ${\kappa}B{\alpha}$ ($I{\kappa}B{\alpha}$). Furthermore, NOD2 or TLR-2 knockdown suppressed the expression of GM-CSF, G-CSF, and $IFN-{\alpha}$ as well as decreased the activation of the cGAS/STING pathway in 29-kDa FN-f-treated chondrocytes. These data demonstrate that the cGAS/STING/TBK1/IRF3 pathway plays a critical role in 29-kDa FN-f-induced expression of pro-inflammatory cytokines.

Effects of Nutritional Conditions on Tobacco (Nicotianatcbfeum L) Cell Suspension Culture (담배세포 (Nicotiana tabacum) 의 액체배양에 관한 연구)

  • 윤경은;김용철;민태기;손세호;강서규
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.1 no.1
    • /
    • pp.1-8
    • /
    • 1979
  • For the preliminary experiments of mass Production of tobacco cells in tank culture, the effects of nutritional conditions on the growth of suspended cells were investigated ; 1. The tobacco cell growth was affected by concentrations of sucrose or inorganic phosphate, type of nitrogen source, and plant hormone, especially 2, 4-D. 2. The optimum level of sucrose concentration was 3% and the level of inorganic phosphate was 0.3mg /ml, which was about twice as high as the level of Linsmaier - Skoog medium. 3. The best growth was observed when the ratio of nitrate nitrogen to ammonium nitrogen was 2 : 1, where the total nitrogen content was equal to that of nitrogen source. 4. To find out the mechanism of promotive effects of 214-D and inorganic phosphate on the tobacco cell growth, the respiration and metabolism of $^{14}\textrm{C}$-91ucose were investigated. Addition of 2, 4 -D in culture medium increased if 2, 4-D (0.2ppm )was added to medium or the level of inorganic Phosphate was raised 2.5 times as high as standard. In cultures with high inorganic phosphate and 2, 4-D, the absorbed 14C-glucose was converted to amino acids and organic acids rather than remained as sugars.

  • PDF