• Title/Summary/Keyword: Type 316N

Search Result 55, Processing Time 0.027 seconds

Optimal Welding Condition of Dissimilar Friction Welded Materials and Its Real Time Evaluation by Acoustic Emission (이종마찰용접재의 최적용접조건과 음향방출에 의한 실시간 품질평가)

  • Kong, Yu-Sik;Lee, Jin-Kyung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.191-199
    • /
    • 2019
  • In this paper, dissimilar friction welding were produced using 15 mm diameter solid bar in chrome molybedenum steel(SCM440) to stainless steel(STS316L) to investigate their mechanical properties. Consequently, optimal welding conditions were n=2000 rpm, HP=70 MPa, UP=140 MPa, HT=10 sec and UT=10 sec when the metal loss(Mo) is 8.6 mm. In addition, an acoustic emission technique was applied to evaluate the optimal friction welding condition. AE parameters including the cumulative count, amplitude and energy showed a various changes according to the friction condition. A continuous type waveforms and low frequency spectrum was presented in friction time. On the other hand, a burst type waveform and high frequency spectrum was exhibited in pressing time.

Long-term evaluation of teeth and implants during the periodic maintenance in patients with viral liver disease

  • Yoon, Da-Le;Kim, Yong-Gun;Cho, Jin-Hyun;Lee, Sang-Kyu;Lee, Jae-Mok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.321-328
    • /
    • 2016
  • PURPOSE. This study was designed to investigate the maintenance of teeth and implants in patients with viral liver disease. MATERIALS AND METHODS. 316 patients without any significant systemic disease were selected as a control group. Liver disease group was consisted of 230 patients. Necessary data were collected using clinical records and panoramic radiographs. Then, the patients were subdivided into 2 groups based on the type of active dental therapy received before maintenance period (Pre-Tx). Analysis for finding statistically significant difference was performed based on the need for re-treatment of active dental therapy (Re-Tx) and change in the number of teeth (N-teeth) and implants (N-implants). RESULTS. Comparing to control group, the patients with liver disease showed higher value on N-teeth, N-implants, and Re-Tx. Statistically significant differences were found on N-teeth (P=.000) and Re-Tx (P=.000) in patients with non-surgical Pre-Tx. Analysis based on severity of liver disease showed that N-teeth and Re-Tx were directly related to severity of liver disease regardless of received type of Pre-Tx. Significant differences were found on N-teeth (P=.003) and Re-Tx (P=.044) in patients with non-surgical Pre-Tx. CONCLUSION. In this study, it was concluded that liver disease might influence the loss of teeth and cause the relapse of dental disease during maintenance period in patients. A significant positive relationship between tooth and implant loss and severity of liver disease seems to exist.

The Development Study of A Manganese Sulphate Bath System ($MnSO_4$용액조 장치 개발 연구)

  • Hwang, Sun-Tae;Lee, Kyung-Ju;Choi, Kil-Oung;Kim, Won-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.70-76
    • /
    • 1986
  • In order to establish the national standards of neutron measurements, a manganese sulphate ($MnSO_4$) bath system was developed under the IAEA technical support. This bath system was made up of a spherical s.s. 316 L bath, of 3.5 mm thick and of 125 cm internal diagmeter, filled with a manganese sulphate solution, a solution circulating system, and a $^5Mn\;{\gamma}-ray$ monitoring system. The solution pumped from the bath was introduced into a Marinelli beaker-type monitor vessel which was equipped with two seperate detectors, $3.8cm{\phi}{\times}3.8cm$ NaI(T1) crystals. The performance of the system were tested using the neutron sources, $^{241}Am-Be\;and\;^{252}Cf$, mounted at the center of the bath. From the decay curve analysis of $^{56}Mn$ activity, neutron emission rate of $^{252}Cf$ by the comparative method was obtained to be $3.71{\times}10^7\;n/s\;per\;50{mu}g$ as of November 15, 1985.

  • PDF

The Effects of Genistein on the Proliferation and Type I pN Collagen Synthesis in Aged Normal Human Fibroblasts (제니스테인에 의한 노화된 피부세포 활성화와 콜라겐 생성 효과)

  • Yang, Eun-Soon;Hong, Ran-Hi;Kang, Sang-Mo
    • Microbiology and Biotechnology Letters
    • /
    • v.35 no.4
    • /
    • pp.316-324
    • /
    • 2007
  • We studied the effects of genistein obtained from glycolysis of genistin, a kind of phytoestrogen present in soybeans, on cell proliferation and type I pN collagen synthesis in normal human dermal fibroblasts(NHDF). Cell proliferation was increased significantly with genistein treatment at 54-year aged NHDF. Genistein increased cell proliferation more strongly in cells form old doner than young doner. The senescence-associated ${\beta}$-galatosidase activity was decreased in NHDF from 77-year old doner with genistein treatment. Type I pN collagen synthesis was increased with genistein treatement in UVA treated and non-treated NHDF. The increasement of collagen synthesis was more effective in aged cells than young cells. Type I pN collagen synthesis was also increased with genistein treatment in collagen matrix culture with NHDF from sun-exposed and non-exposed skin from 54-year old doner. Genistein treatment inhibited MMP-1 synthesis in old NHDF but not in young NHDF. In conclusion, genistein may be a useful agent for preventing intrinsic aging as well as photoaging.

A Study on Improving Shock Absorption Test of Safety Helmet (안전모의 충격 흡수성 시험 개선에 관한 연구)

  • Sang Woo Shim;Yong Su Sim;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.36-42
    • /
    • 2023
  • In this study, 50 ABE-type hard hats were procured from five certified commercial manufacturers, and shock absorption tests were conducted in accordance with Protective Equipment Safety Certification Notice No. 2020-35. The tests were performed under both high- and low-temperature conditions, adhering to safety helmet testing standards. The highest shock transmission ranges were recorded in the tests, with an average energy range of 2,600-4,108 N at high temperatures and 2,316-3,991 N at low temperatures. All five hard hat models demonstrated a maximum transmitted impact force below 4,450 N, without any loss of cap and attachment functionality, confirming their compliance with performance standards. Furthermore, we evaluated the side impact performance of the safety helmets of each company, with an average range of 4,722-5,267 N. Company A exhibited the lowest measurement at 4,722 N. Comparing these results with international safety standards and the national shock absorption test criteria, it was observed that the maximum transmitted shock value using government-specified impact weight falls within the range of 4,450-5,000 N. However, it was noted that developed countries have established specific standards for the side impact forces on safety helmets, which are legally mandated. Consequently, it is imperative for South Korea to enhance its safety helmet side impact performance test methodology to align with domestic standards in the future.

Effect of core design on fracture resistance of zirconia-lithium disilicate anterior bilayered crowns

  • Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra;Huh, Yoon-Hyuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.181-188
    • /
    • 2020
  • PURPOSE. The effect of core design on the fracture resistance of zirconia-lithium disilicate (LS2) bilayered crowns for anterior teeth is evaluated by comparing with that of metal-ceramic crowns. MATERIALS AND METHODS. Forty customized titanium abutments for maxillary central incisor were prepared. Each group of 10 units was constructed using the same veneer form of designs A and B, which covered labial surface to approximately one third of the incisal and cervical palatal surface, respectively. LS2 pressed-on-zirconia (POZ) and porcelain-fused-to-metal (PFM) crowns were divided into "POZ_A," "POZ_B," "PFM_A," and "PFM_B" groups, and 6000 thermal cycles (5/55 ℃) were performed after 24 h storage in distilled water at 37 ℃. All specimens were prepared using a single type of self-adhesive resin cement. The fracture resistance was measured using a universal testing machine. Failure mode and elemental analyses of the bonding interface were performed. The data were analyzed using Welch's t-test and the Games-Howell exact test. RESULTS. The PFM_B (1376. 8 ± 93.3 N) group demonstrated significantly higher fracture strength than the PFM_A (915.8 ± 206.3 N) and POZ_B (963.8 ± 316.2 N) groups (P<.05). There was no statistically significant difference in fracture resistance between the POZ_A (1184.4 ± 319.6 N) and POZ_B groups (P>.05). Regardless of the design differences of the zirconia cores, fractures involving cores occurred in all specimens of the POZ groups. CONCLUSION. The bilayered anterior POZ crowns showed different fracture resistance and fracture pattern according to the core design compared to PFM.

Elective neck treatment in clinically node-negative paranasal sinus carcinomas: impact on treatment outcome

  • Lee, Won Hee;Choi, Seo Hee;Kim, Se-Heon;Choi, Eun Chang;Lee, Chang Geol;Keum, Ki Chang
    • Radiation Oncology Journal
    • /
    • v.36 no.4
    • /
    • pp.304-316
    • /
    • 2018
  • Purpose: The indication of elective neck treatment (ENT) for clinically N0 (cN0) paranasal sinus (PNS) carcinoma remains unclear. We aimed to investigate different treatment outcomes regarding ENT and propose optimal recommendations for ENT. Materials and Methods: We identified patients with cN0 PNS carcinoma who underwent curative-intent treatment between 1992 and 2015. Survival outcomes and pattern of failure were compared between patients who received ENT and those who did not. We sought to identify significant patient or pathologic factors regarding treatment outcomes. Results: Among 124 patients meeting the inclusion criteria, 40 (32%) received ENT ('ENT (+) group') and 84 (68%) did not ('ENT (-) group'). With a median follow-up of 54 months, the 5-year overall survival (OS) was 67%, and the 5-year progression-free survival (PFS) was 45%. There was no significant difference between the ENT (+) and ENT (-) groups regarding OS (p = 0.67) and PFS (p = 0.50). Neither group showed a significantly different pattern of failure, including regional failure (p = 0.91). There was no specific benefit, even in the subgroups analysis by tumor site, histologic type, and T stage. Nevertheless, patients who ever had regional and/or distant failure showed significantly worse prognosis. Conclusion: ENT did not significantly affect the survival outcome or pattern of failure in patients with cN0 PNS carcinomas, showing that ENT should not be generalized in this group. However, further discussion on the optimal strategy for ENT should continue because of the non-negligible regional failure rates and significantly worse prognosis after regional failure events.

Effects of packaging gas on the quality characteristics of dried persimmons (포장 기체가 곶감의 품질 특성에 미치는 영향)

  • Choi, Ji-Young;Lee, Hyun-Jae;Jang, Jong-Wook;Kwon, Kwang-Woo;Kim, Ji-Soo;Moon, Kwang-Deog
    • Korean Journal of Food Science and Technology
    • /
    • v.50 no.3
    • /
    • pp.316-323
    • /
    • 2018
  • This study aimed to analyze the effect of packaging gas type on the quality characteristics of dried persimmon during a 60-day storage period. The samples were stored at 10 and $-10^{\circ}C$. Experimental samples were either untreated (CON) or packed with carbon dioxide ($CO_2$), nitrogen ($N_2$), or argon (Ar) gases. In terms of the CIE $a^*$ (redness) and $b^*$ (yellowness) values, the least changes were observed in the Ar package. The color difference observed in the $N_2$ package was found to be the highest at $-10^{\circ}C$. Ar and $CO_2$ packages showed the highest and lowest water content, respectively, at $10^{\circ}C$. Sensory evaluation showed a high score for Ar packages. At $10^{\circ}C$, the score of the Ar package was the highest until day 40 and that of the $CO_2$ package was the highest from day 40 to 60. At $-10^{\circ}C$, the score of the Ar package was the highest. These results show that $N_2$- and Ar-modified packaging is the most desirable, thus suggesting its application in actual market.

CLINICOSTATISTICAL STUDY ON ORTHOGNATHIC SURGERY IN OUR DEPARTMENT (본 교실에서 시행한 악교정 수술 증례에 관한 임상적 연구)

  • Lee, Sang-Han;Park, In-Sook;Lee, Chang-Hwan;Kwon, Tae-Geon;Yun, Man;Deng, Fangchen
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.255-259
    • /
    • 2005
  • We observed 469 cases (male 217 cases, female 252 cases) with dento-facial deformity for 10 years from Jan 1994 to Dec 2003. The ratio of male to female was 1:1.2 and the mean age was 23.3 years (male 24.0 years, female 22.6 years) ranged from 11 to 43 years. The most dominant group was related to mandibular prognathism (80.4%). A rate of 83.8% demonstrated mandibular protrusion according to Slavicek's classification (n=160), and 85.4% were classified as skeletal Class III type according to Sugawara's classification (n=151). Surgical method were divided into 355 cases of one jaw surgery (single method), 26 cases of one jaw surgery (combined method), and 77 cases of two jaw surgery. Sagittal split osteotomy were performed on 316 cases (69.0%). The average operation time and blood loss in SSRO were $4.1{\pm}2.2$ hrs. and $138.8{\pm}222.6$ ml (n=152).

COMPARISONS OF PARALLEL PRECONDITIONERS FOR THE COMPUTATION OF SMALLEST GENERALIZED EIGENVALUE

  • Ma, Sang-Back;Jang, Ho-Jong;Cho, Jae-Young
    • Journal of applied mathematics & informatics
    • /
    • v.11 no.1_2
    • /
    • pp.305-316
    • /
    • 2003
  • Recently, an iterative algorithm for finding the interior eigenvalues of a definite matrix by CG-type method has been proposed. This method compares to the inverse power method. The given matrices A, and B are assumed to be large and sparse, and SPD( Symmetric Positive Definite) The CG scheme for the optimization of the Rayleigh quotient has been proven a very attractive and promising technique for large sparse eigenproblems for smallest eigenvalue. Also, it is very amenable to parallel computations, like the CG method for the linear systems. A proper choice of the preconditioner significantly improves the convergence of the CG scheme. But for parallel computations we need to find an efficient parallel preconditioner. Our candidates we ILU(0) in the wave-front order, ILU(0) in the multi-coloring order, Point-SSOR(Symmetric Successive Overrelaxation), and Multi-Color Block SSOR preconditioner. Wavefront order is a simple way to increase parallelism in the natural order, and Multi-coloring realizes a parallelism of order(N), where N is the order of the matrix. Another choice is the Multi-Color Block SSOR(Symmetric Successive OverRelaxation) preconditioning. Block SSOR is a symmetric preconditioner which is expected to minimize the interprocessor communication due to the blocking. We implemented the results on the CRAY-T3E with 128 nodes. The MPI (Message Passing Interface) library was adopted for the interprocessor communications. The test problem was drawn from the discretizations of partial differential equations by finite difference methods. The results show that for small number of processors Multi-Color ILU(0) has the best performance, while for large number of processors Multi-Color Block SSOR performs the best.