• 제목/요약/키워드: Two-way Imaging

검색결과 70건 처리시간 0.028초

A Synthetic Aperture Focusing Method for Three-way Dynamic Focusing

  • Kim Jung-Jun;Chang Jin-Ho;Song Tai-Kyong
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권1호
    • /
    • pp.31-35
    • /
    • 2005
  • A novel synthetic aperture method for real-time three-way dynamic focusing is proposed, which provides lateral beam patterns represented as the product of Fourier transforms of transmit subaperture, receive subaperture, and a synthetic window function. In the proposed method, all array elements are fired individually and for each firing echo signals are recorded from all elements of a receive subaperture moving along an array with the transmit element. The three-way dynamic focusing is then achieved by employing a synthetic aperture algorithm for two-way dynamic focusing and a synthetic focusing method for transmit dynamic focusing. Both theoretical analysis and computer simulation results show that the proposed method produces ultrasound beams with improved lateral resolution at all depths compared to the conventional phased array imaging and synthetic aperture focusing methods.

Accelerated Resting-State Functional Magnetic Resonance Imaging Using Multiband Echo-Planar Imaging with Controlled Aliasing

  • Seo, Hyung Suk;Jang, Kyung Eun;Wang, Dingxin;Kim, In Seong;Chang, Yongmin
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권4호
    • /
    • pp.223-232
    • /
    • 2017
  • Purpose: To report the use of multiband accelerated echo-planar imaging (EPI) for resting-state functional MRI (rs-fMRI) to achieve rapid high temporal resolution at 3T compared to conventional EPI. Materials and Methods: rs-fMRI data were acquired from 20 healthy right-handed volunteers by using three methods: conventional single-band gradient-echo EPI acquisition (Data 1), multiband gradient-echo EPI acquisition with 240 volumes (Data 2) and 480 volumes (Data 3). Temporal signal-to-noise ratio (tSNR) maps were obtained by dividing the mean of the time course of each voxel by its temporal standard deviation. The resting-state sensorimotor network (SMN) and default mode network (DMN) were estimated using independent component analysis (ICA) and a seed-based method. One-way analysis of variance (ANOVA) was performed between the tSNR map, SMN, and DMN from the three data sets for between-group analysis. P < 0.05 with a family-wise error (FWE) correction for multiple comparisons was considered statistically significant. Results: One-way ANOVA and post-hoc two-sample t-tests showed that the tSNR was higher in Data 1 than Data 2 and 3 in white matter structures such as the striatum and medial and superior longitudinal fasciculus. One-way ANOVA revealed no differences in SMN or DMN across the three data sets. Conclusion: Within the adapted metrics estimated under specific imaging conditions employed in this study, multiband accelerated EPI, which substantially reduced scan times, provides the same quality image of functional connectivity as rs-fMRI by using conventional EPI at 3T. Under employed imaging conditions, this technique shows strong potential for clinical acceptance and translation of rs-fMRI protocols with potential advantages in spatial and/or temporal resolution. However, further study is warranted to evaluate whether the current findings can be generalized in diverse settings.

Extraction of Sizes and Velocities of Spray Droplets by Optical Imaging Method

  • Choo, Yeonjun;Kang, Boseon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권7호
    • /
    • pp.1236-1245
    • /
    • 2004
  • In this study, an optical imaging method was developed for the measurements of the sizes and velocities of droplets in sprays. Double-exposure single-frame spray images were captured by the imaging system. An image processing program was developed for the measurements of the sizes and positions of individual particles including separation of the overlapped particles and particle tracking and pairing at two time instants. To recognize and separate overlapping particles, the morphological method based on watershed segmentation as well as separation using the perimeter and convex hull of image was used consecutively. Better results in separation were obtained by utilization of both methods especially for the multiple or heavily-overlapped particles. The match probability method was adopted for particle tracking and pairing after identifying the positions of individual particles and it produced good matching results even for large particles like droplets in sprays. Therefore, the developed optical imaging method could provide a reliable way of analyzing the motion and size distribution of droplets produced by various sprays and atomization devices.

25\μm 홀 펀칭 공구 정렬을 위한 광학 시스템 설계 (Design of Two-way Image Acquisition System for 25\μm Tool Alignment in the Micro Hole Punching)

  • 주병윤;임성한;오수익
    • 소성∙가공
    • /
    • 제13권3호
    • /
    • pp.190-204
    • /
    • 2004
  • The objective of this study is to develop a highly accurate micro tool alignment system applicable to the micro machining technology. In a specific application such as micro hole punching, radial clearance between micro tools is order of a few micron. Under this micron scale tool clearance, accuracy of tool alignment is very important for ensuring hole quality. In the present study, a two-way image acquisition system was developed, which can produce overlapped image of both micro tools that face each other, and applied to the tool alignment in the micro punching. Also, to meet alignment accuracy of tools within $1\mu\textrm{m}$, the cross correlation image processing algorithm was employed. With this system, $25\mu\textrm{m}$ punching tools with $1\mu\textrm{m}$ radial clearance could be accurately aligned.

An Efficient Focusing Method for High Resolution Ultrasound Imaging

  • Kim Kang-Sik
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권1호
    • /
    • pp.22-29
    • /
    • 2006
  • This paper proposes an efficient array beamforming method using spatial matched filtering for ultrasound imaging. In the proposed method, ultrasound waves are transmitted from an array subaperture with fixed transmit focus as in conventional array imaging. At receive, radio frequency (RF) echo signals from each receive channel are passed through a spatial matched filter that is constructed based on the system transmit-receive spatial impulse response. The filtered echo signals are then summed. The filter remaps and spatially registers the acoustic energy from each element so that the pulse-echo impulse response of the summed output is focused with acceptably low side lobes. Analytical beam pattern analysis and simulation results using a linear array show that the proposed spatial filtering method can provide more improved spatial resolution and contrast-to-noise ratio (CNR) compared with conventional dynamic receive focusing (DRF) method by implementing two-way dynamically focused beam pattern throughout the field.

CCD image system을 갖는 유전체칩 분석장치를 위한 효율적인 광학시스템 설계 (Effective Optical System Design for Biochip Analyzer with CCD Image System)

  • 배수진;강욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.488-491
    • /
    • 2003
  • Biochip-based diagnostic technology is an effective, time- and money- saving way. But, biochip analyzer including CCD imaging system has a complete optical system. It is one of reasons that the cost of biochip analyzer is expensive with CCD imaging system. In this paper, We suggested the simple and effective optical system for biochip analyzer with CCD imaging system. It consists of two parts with the same structure but opposite direction. Each part consists of achromatic doublet and meniscus. Suggested optical system has less lenses than existing system and more efficiently.

  • PDF

안테나배열을 이용한 콘크리트부재 내부의 비파괴시험과 영상화방법 개발 (Subsurface Imaging Technology For Damage Detection of Concrete Structures Using Microwave Antenna Array)

  • 김유진;최고일;장일영
    • 한국방재학회 논문집
    • /
    • 제5권2호
    • /
    • pp.1-8
    • /
    • 2005
  • 콘크리트 구조물 내부 결함이나 철근 위치를 탐지하기 위하여 초단파를 이용하는 비파괴 시험방법이 구조물 안전진단 분야에서도 최근 관심을 불러일으키고 있다. 본 연구의 목적은 기 개발된 2차원 영상화 방법을 확장하여 3차원 영상처리방법을 개발하는 것이다. 그 방법으로 콘크리트 구조물 내의 결함을 탐지하기 위한 안테나를 구성, 수치적 초점조절시스템을 이용하여 송신부와 수신부의 초점을 동시 조절하여 구조물 내부의 모든 부분을 검색하였다. 또한 다중주파수 방식을 이용, 데이터의 오류를 제거하고 해상도를 향상시켜 구조물 내부의 결함이나 내부모습을 탐지할 수 있는 3차원 영상장치를 개발하고자 하였다. 실험 결과, 데이터 오류를 줄이는 다중주파수방식에 의하여 재현된 영상의 정확성을 검증하고, 주파수 조절방법에 의하여 $4{\times}4$ 안테나배열을 설계함으로써 5.2 GHz에서 주파수대역의 우수한 투과성능을 입증하였다. 즉 본 연구에서 개발된 슬롯안테나는 파동의 방사기능과 주파수대역의 넓이 등에서 구조부재의 결함탐지에 이용될 수 있음을 검증하였다.

Metal artifact production and reduction in CBCT with different numbers of basis images

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Groppo, Francisco Carlos;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.41-44
    • /
    • 2018
  • Purpose: To evaluate the effect of different numbers of basis images and the use of metal artifact reduction (MAR) on the production and reduction of artifacts in cone-beam computed tomography images. Materials and Methods: An acrylic resin phantom with a metal alloy sample was scanned, with 450 or 720 basis images and with or without MAR. Standard deviation values for the test areas (around the metal object) were obtained as a way of measuring artifact production. Two-way analysis of variance was used with a 5% significance level. Results: There was no significant difference in artifact production among the images obtained with different numbers of basis images without MAR (P=.985). MAR significantly reduced artifact production in the test areas only in the protocol using 720 basis images (P=.017). The protocol using 450 basis images with MAR showed no significant difference in artifact production when compared to the protocol using 720 basis images with MAR (P=.579). Conclusion: Protocols with a smaller number of basis images and with MAR activated are preferable for minimizing artifact production in tomographic images without exposing the patient to a greater radiation dose.

A Study on the Isodose Distribution in a Vascular Characterization Room

  • Choi, Young;Kang, Byung-Sam;Min, Jung-Whan
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.7-11
    • /
    • 2011
  • As applications of radiation grow wider from use in the early detection of lesions and preventive diagnosis purposes to the treatment of diseases, the possibilities for patients and working professionals to be exposed to radiation are becoming greater than ever. This can not only directly bring about an increase in patient's individual radiation exposure, but also brings about an increase in the annual radiation dose of working professionals. Therefore, research and countermeasures to reduce radiation dosage are required. In this study, space dosimetry has been divided into two separate measuments with an understanding of the increasing number of angiography procedures: front perspective and side perspective. According to the results of the isodose curve, a way to minimize radiation exposure in working professionals has been suggested. This was made possible by workers through awareness of suitable working positions.

  • PDF

CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구 (Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries)

  • 이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF