• 제목/요약/키워드: Two-switch

검색결과 804건 처리시간 0.028초

원자력 발전소 주 제어반의 제어 스위치 배치에 대한 인지적 수행도 평가 (A Cognitive Evaluation of Hand Switch Layouts in the Main Control Board of Nuclear Power Plants)

  • 변승남;이동훈
    • 대한산업공학회지
    • /
    • 제26권2호
    • /
    • pp.136-145
    • /
    • 2000
  • The objective of this study is to evaluate the human performance relating to the layouts of the two different hand switch types with two and three buttons in the nuclear power plants. Using a computer simulation, the cognitive performance for the hand switch layouts was measured on the basis of response and task completion times. Comparative analyses were performed with three different layouts representing the current switch arrangements in the Yonggwang nuclear plants 5 and 6 and Ulchin 3 and 4, respectively. Statistical analyses revealed that the performance of the two-buttoned switch layouts was found to be better than those of the three-buttoned switch. Furthermore, the superiority of the two-buttoned switch type is consistent regardless of various layout types. These results imply that the difference of the cognitive performance can be attributable to the switch types rather than to the switch layouts. Therefore, from the cognitive perspective, the two-buttoned switch type is recommended for future power nuclear plants.

  • PDF

Advanced Three-Phase PFC Power Converters with Three-Phase Diode Rectifier and Four-Switch Boost Chopper

  • Nishimura Kazunori;Hirachi Katsuya;Hiraki Eiji;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.356-365
    • /
    • 2006
  • This paper presents an improved three-phase PFC power rectifier with a three-phase diode rectifier cascaded four-switch boost converter. Its operating principle contains the operating principle of two conventional three-phase PFC power rectifiers: one switch boost converter type and a two switch boost converter type. The operating characteristics of the four switch boost converter type three-phase PFC power rectifier are evaluated from a practical point of view, being compared with one switch boost converter type and two switch boost converter topologies.

보조 스위치를 사용한 ZVS Two-Switch 포워드 컨버터에 대한 연구 (A Study of ZVS Two-Switch Forward Converter Using Auxiliary Switch)

  • 정민혁;김용;엄태민;이규훈;이동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.965_966
    • /
    • 2009
  • In this paper, a new soft-switching Two-switch Forward converter topology has been proposed. Compared with conventional two-switch forward converter, the proposed converter employs an auxiliary switch and a clamp capacitor to instead of two reset diodes, not only its duty cycle can exceed 0.5 to achieve wide range input voltage, but also soft switching can be achieved for all switches. Especially, voltage stress across main switches can be clamped at $1/2V_{in}$, voltage stress across auxiliary switch can be clamped at $V_{in}$. In addition, due to clamp capacitor series with the transformer, duty ratio can be extended with equation $V_o=\frac{V_{in}(1-D}D{N}$. Therefore, as a kind of better cost-effective approach, it is very attractive for high input, wide range and high efficiency application.

  • PDF

Space-vector PWM Techniques for a Two-Phase Permanent Magnet Synchronous Motor Considering a Reduction in Switching Losses

  • Lin, Hai;Zhao, Fei;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.905-915
    • /
    • 2015
  • Two PWM techniques using space vector pulse-width modulation (SVPWM) are proposed for a two-phase permanent magnet synchronous motor (PMSM) driven by a two-phase eight-switch inverter. A two-phase motor with two symmetric stator windings is usually driven by a two-phase four-, six-, or eight-switch inverter. Compared with a four- and six-switch inverter, a two-phase eight-switch inverter can achieve larger power output. For two-phase motor drives, the SVPWM technique achieves more efficient DC bus voltage utilization and less harmonic distortion of the output voltage. For a two-phase PMSM fed by a two-phase eight-switch inverter under a normal SVPWM scheme, each of the eight PWM trigger signals for the inverter have to be changed twice in a cycle, causing a higher PWM frequency. Based on the normal SVPWM scheme, two effective SVPWM schemes are investigated in order to reduce the PWM frequency by rearranging four comparison values, while achieving the same function as the normal PWM scheme. A detailed explanation of the normal and two proposed SVPWM schemes is illustrated in the paper. The experimental results demonstrate that the proposed schemes achieve a better steady performance with lower switching losses compared with the normal scheme.

단일전력단 Two-Switch Forward 컨버터에 관한 연구 (A Study on the Single-Stage Two-Switch Forward Converter)

  • 배진용;김용
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.60-66
    • /
    • 2005
  • 본 연구에서는 단일전력단 Two-Switch Forward 컨버터에 관하여 논하였다. 최근 국제적으로 제정된 ICE 61000-3-2와 IEEE 519같은 규정에서 입력 전류에 대한 고조파 규제가 강화되면서 전원 공급 장치의 역률개선 회로가 필수적으로 되었다. 따라서 본 연구에서는 저전압 대전류 출력에 적합한 방안으로 단일전력단 Two-Switch Forward 컨버터 회로를 제안하고, 모드별 동작, 특성 및 설계에 관하여 논하였으며, MOSFET를 사용하여 200[W](5[V], 40[A])급 시작품을 제작, 100[kHz]에서 실험하였다.

Actively Clamped Two-Switch Flyback Converter with High Efficiency

  • Yang, Min-Kwon;Choi, Woo-Young
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1200-1206
    • /
    • 2015
  • This paper proposes an actively clamped two-switch flyback converter. Compared to the conventional two-switch flyback converter, the proposed two-switch flyback converter operates with a wide duty cycle range. By using an active-clamp circuit, the proposed converter achieves zero-voltage switching for all of the power switches. Zero-current switching of an output diode is also achieved. Thus, compared with the conventional converter, the proposed converter realizes a higher efficiency with an extended duty cycle. The performance of the proposed converter is verified by the experimental results with use of a 1.0 kW prototype circuit.

대용량 2단 ATM 스위치와 그 특성에 관한 연구 (A Study on the Two-Stage ATM Switch and Its Traffic Characteristics)

  • 송광석;김윤철;한치문;이태원
    • 전자공학회논문지A
    • /
    • 제29A권7호
    • /
    • pp.19-30
    • /
    • 1992
  • In this paper, a new large scale ATM switch architecture for Broadband ISDN is presented and its performance is analyzed mathematically. The proposed two-stage ATM switch consists of a sorting network and several unit switches. The proposed switch is self-routing and nonlocking. Its maximum through put is 100% without speed up which other output buffered switch needs. The hardware complexity mainly depends on that of a sorting network, but sorting network is easy to be implemented to VLSI because of its regularity in the structure.

  • PDF

주관적 작업부하 평가기법을 이용한 원자력 발전소 주제어반 제어 스위치 사용 인적 수행도 평가 (An Evaluation of Operator Performance Related to the Switch Types in Man Control Rooms of the Nuclear Power Plants)

  • 변승남
    • 대한산업공학회지
    • /
    • 제26권1호
    • /
    • pp.54-65
    • /
    • 2000
  • The objective of this study is to evaluate the operator performance relating to hand switches with two or three buttons in the main control rooms of nuclear power plants. Based on the comparative analysis of the nuclear power plants, two different subjective workload-rating scales were used to evaluate the performance of 48 operators: the Overall Workload(OW) and National Aeronautics and Space Administration Task Load Index (NASA TLX). The survey questions consisting of the eight-items were asked to evaluate the operating experiences for the two different switch types. The OW scales ratings were applied to measure the workload of the switch-related tasks. The ratings revealed that signal detection tasks caused less workload in the three-buttoned-switch operators than the other switch group. However, in the switch operation tasks, the switch types did not show statistically significant effects on workload level. The NASA TLX scale ratings were performed based on detailed task scenarios that assumed the accident of small break loss of coolant, what we call, the small LOCH. The NASA TLX was administered to three different task groups: the reactor, the turbine, and the electric operator groups. Based on the NASA TLX, the two-buttoned switch groups showed higher workload than those with the three-buttoned switches. However, a statistically significant difference was found only in the reactor operator groups. When the current switch type was assumed to be changed for the other type, all of the three-buttoned switch groups were predicted to have higher workload than the other switch groups, respectively. The implications of these findings were discussed.

  • PDF

A Novel Algorithm for Maintaining Packet Order in Two-Stage Switches

  • Zhang, Xiao Ning;Xu, Du;Li, Le Min
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.469-472
    • /
    • 2005
  • To enhance the scalability of high performance packet switches, a two-stage load-balanced switch has recently been introduced, in which each stage uses a deterministic sequence of configurations. The switch is simple to make scalable and has been proven to provide 100% throughput. However, the load-balanced switch may mis-sequence the packets. In this paper, we propose an algorithm called full frame stuff (FFS), which maintains packet order in the two-stage load-balanced switch and has excellent switching performance. This algorithm is distributed and each port can operate independently.

  • PDF

A Novel Soft-Switching Two-Switch Flyback Converter with a Wide Operating Range and Regenerative Clamping

  • Kim, Marn-Go;Jung, Young-Seok
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.772-780
    • /
    • 2009
  • A novel soft-switching two-switch flyback converter is proposed in this paper. This converter is composed of two active power switches, a flyback transformer, a blocking diode, and two passive regenerative clamping circuits. The proposed converter has the advantages of a low cost circuit configuration, a simple control scheme, a high efficiency, and a wide operating range. The circuit topology, analysis, design considerations, and experimental results of the new flyback converter are presented.