• Title/Summary/Keyword: Two-stage

Search Result 8,694, Processing Time 0.033 seconds

A Multi-Stage CMOS Charge Pump for Low-Voltage Memories

  • Lim, Gyu-Ho;Yoo, Sung-Han;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.283-287
    • /
    • 2002
  • To remedy both the degradation and saturation of the output voltages in the modified Dickson pump. a new multi-stage charge pump circuit is presented in this paper. Here using PMOS charge-transfer switches instead of NMOS ones eliminates the necessity of diode-configured output stage in the modified-Dickson pump, achieving the improved voltage pumping gain and its output voltages proportional to the stage numbers. Measurement indicates that VOUT/3VDD of this new pump circuit with two stages reaches to a value as high as 0.94 even with low VDD=1.0 V, strongly addressing that this scheme is very favorable at low-voltage memory applications.

  • PDF

Single Stage PFC Flyback Converter Using Top Switch (Top 스위치를 이용한 단일 전력단 역률개선 플라이백 컨버터)

  • Lim Chang Seob;Kwon Soon Kurl;Lee Hyun Woo;Kim Eun Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.669-672
    • /
    • 2001
  • Generally, previous converter is divided into two categories to get high power factor and good output regulation. These two categories can be combined a category with a main switch. These converter is called Single Stage PFC Converter. This approach has good electrical characteristics of high power factor and fast output voltage regulation. The cost and size are important factor to design the converter in low power system. Even single stage can reduce the size and cost, but this approach needs to have additional circuit like control, PWM circuit. To improve these demerits, Top switch is one of good choice In reduce and size in low power single stage converter. Because it has the ability of current limit, thermal protection, oscillator, control circuit as well as a main switch ability.

  • PDF

Study on Micro Endmilling Process for Manufacturing of Very Small Gear Parts and Mold with Two-Stage (미소 2단 기어 부품 금형 가공을 위한 마이크로 엔드밀링 공정기술 연구)

  • Je, T.J.;Noh, J.S.;Kim, B.D.;Kim, J.G.;Yoon, J.S.
    • Transactions of Materials Processing
    • /
    • v.19 no.2
    • /
    • pp.107-112
    • /
    • 2010
  • A multi-stage gear mold including gears of 2mm and 1.5mm diameter was designed and machined in this research for developing micro gear mold manufacturing technology with micro endmill. Mechanical shapes having differential micro teeth were analyzed to be formed as designed and processing conditions were optimized by analyzing machined surface chip and cutting force. Based on the results, a prototype of micro multi-stage gear mold was manufactured.

Evaluating Higher Diploma in English Language Teaching for the Primary Stage from the Teachers' Perspectives

  • Hashem A. Alsamadani
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.9
    • /
    • pp.91-94
    • /
    • 2023
  • This study aims to evaluate the Higher Diploma in English for the Primary Stage from the diploma students' perspectives. A questionnaire was designed consisting of 25 items distributed in two areas: cognitive/academic preparation and professional/skill preparation. The following statistical analyses were used: means, standard deviations, t-test, and one-way analysis of variance (ANOVA). The study results showed that the level of evaluation of the two domains in the program was low. The study also showed no statistically significant differences between the means of educational diploma students when evaluating the Higher Diploma in English for the Primary Stage due to their academic specialization (Arabic language, social sciences, and Islamic studies). In conclusion, the researcher suggested a developmental mechanism derived from the study results to improve the higher Diploma in English for the Primary Stage.

Design of a Converter with Anti-blinking Circuitry for T5 LED Indirect Lighting

  • Woo-young, Kim;Quoc Cuong Nguyen;Seong-Kweon Kim
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.103-111
    • /
    • 2024
  • We address the problematic issue of blinking in residential LED lighting systems-a phenomenon that has recently become a significant concern due to voltage sags caused by high-power household appliances. To combat this, we developed a two-stage LED converter with integrated anti-blinking circuitry, specifically designed for T5 LED indirect lighting fixtures. The first stage employs a Power Factor Correction (PFC) boost circuit to enhance voltage stability by aligning the voltage and current phases, thereby minimizing power losses. The second stage, a meticulously engineered DC-DC buck converter, ensures stable lighting despite electrical fluctuations. Rigorous testing has confirmed our converter's efficacy in maintaining consistent light output without blinking, thereby substantially improving user comfort and adhering to strict standards for harmonic distortion and electromagnetic compatibility. Our breakthrough provides a robust solution to a pressing issue, marking a significant advancement in LED lighting technology.

A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

  • Park Chan-Jin;Kim Yung-Soo;Kim Chang-Whe;Cho Lee-Ra;Yi Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.271-287
    • /
    • 2003
  • Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

New CCM Single Stage PFC Full Bridge Converter (새로운 CCM 단일 전력단 역률보상 풀 브리지 컨버터)

  • Lim, Chang-Seob;Kwon, Soon-Kurl;Cho, Jung-Goo;Song, Doo-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.986-989
    • /
    • 2002
  • This paper proposes a new single stage power factor correction (PFC) full bridge converter which operates at continuous conduction mode(CCM). The proposed single stage PFC consists of typical zero voltage switching(ZVS) full bridge DC/DC converter, two transformer auxiliary windings, and two small inductors, and two diodes. Neither additional active switch nor any control circuit are added for PFC resulting in very low cost. The proposed converter provides input power factor correction with CCM control and tight output voltage regulation. All switching devices are operated under ZVS with minimum voltage stress. Operation principle and analysis are explained and verified with computer simulation and experimental results on a 1.2kW, 100kHz prototype.

  • PDF

Prediction of unmeasured mode shapes and structural damage detection using least squares support vector machine

  • Kourehli, Seyed Sina
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.3
    • /
    • pp.379-390
    • /
    • 2018
  • In this paper, a novel and effective damage diagnosis algorithm is proposed to detect and estimate damage using two stages least squares support vector machine (LS-SVM) and limited number of attached sensors on structures. In the first stage, LS-SVM1 is used to predict the unmeasured mode shapes data based on limited measured modal data and in the second stage, LS-SVM2 is used to predicting the damage location and severity using the complete modal data from the first-stage LS-SVM1. The presented methods are applied to a three story irregular frame and cantilever plate. To investigate the noise effects and modeling errors, two uncertainty levels have been considered. Moreover, the performance of the proposed methods has been verified through using experimental modal data of a mass-stiffness system. The obtained damage identification results show the suitable performance of the proposed damage identification method for structures in spite of different uncertainty levels.

Analysis and Comparison of Switching Losses and Temperature using Si and SiC devices applied in Two Stage AC-DC Converter for Battery Pack Testing System (배터리팩 시험기를 위한 2단 구성 AC-DC 컨버터의 Si와 SiC의 손실 및 온도 비교 분석)

  • Seong, Ho-Jae;Choi, Hyeong-Jun;Hong, Seok-Jin;Hyun, Seung-Wook;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.397-398
    • /
    • 2016
  • This paper analyzes switching losses, efficiency and temperature depending on Si and SiC devices applied in two stage AC-DC converter. To evaluate the charge and discharge performance and stability of the battery pack, there is a need for a battery pack testing system. To do battery charge and discharge experiment used in battery pack test, A topology, two stage AC-DC converter, has been built. SiC devices more decrease switching losses than that of Si. Also, cooling system was applied in Si and SiC devices. When using SiC devices, it can be confirmed that the size of heat sink is reduced for small loss.

  • PDF

A Numerical Simulation of Projectile Aerodynamics Using a Ballistic Range (Ballistic Range를 이용한 Projectile 공기역학의 수치모사)

  • Jung S. J.;Rajesh G.;Kim H. D.;Lee J. M.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.386-393
    • /
    • 2005
  • The objective of the present study is to develop a new type of the Ballistic range, called 'two-stage light gas gun'. A computational work has been performed to investigate the aerodynamics of a projectile which is launched from the two-stage light gas gun. A moving coordinate method for a multi-domain technique is employed to simulate unsteady projectile flows with a moving boundary. The effect of a virtual mass is added to the axisymmetric unsteady Euler equation systems. The computed results reasonably capture the major flow characteristics which are generated in launching the projectile supersonically, such as the interaction between the shock wave and the blast wave, the interaction between the vortical flow and the barrel shock, and the steady under-expanded jet. The present computational results properly predict the velocity, acceleration, and drag histories of the projectile.

  • PDF