• Title/Summary/Keyword: Two-point calibration curve

검색결과 4건 처리시간 0.022초

TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가 (Utility Evaluation of Two-point Calibration Curve applied for TSH, FT4 Tests)

  • 박혜미;유선희;이선호;김년옥
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.75-79
    • /
    • 2016
  • Purpose The ASAN Medical Center, Nuclear Medicine performs TSH (Thyroid stimulating hormone) and FT4 (Free Thyroxine) tests 8 times per day. Accordingly, 70 ~ 80 kit tubes are consumed every day for the measurements and the time consumed for reagent dispensing averages over 170 seconds, where the TAT (turnaround time) may be effected when the number of test samples is larger than expected. Therefore, the following test was conducted with the purpose to reduce the number of kit tubes consumed, and reduce the time for reagent dispensing. Materials and Methods The test is based on applying the same reagent for tests where the number of samples is 30 or less. The test for TSH was conducted 9 times from July $1^{st}$ 2015 to July $10^{th}$ 2015. The test for FT4 was conducted 4 times from June $18^{th}$ 2015 to June $22^{nd}$, 2015. Standard Solution No.2 (0.153 uU/mL) and No.5 (4.96 uU/mL) was selected as the two-point standards for the TSH test, and Standard Solution No.3 (0.777 ng/dL) and No.4 (2.044 ng/dL) was selected as the two-point standards for the FT4 test. 38 test samples were subject to correlation analysis. Results For TSH, the result of the normal test shows ranges of 0.20 ~ 0.37 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 6.77 ~ 7.94uU/mL for Control3, while the result of two-point calibration curve test shows ranges of 0.18 ~ 0.27 uU/mL for Control1, 0.53 ~ 0.71 uU/mL for Control2, and 7.30 ~ 8.52 uU/mL for Control3. For FT4, the result of the normal test shows ranges of 0.85 ~ 0.94 ng/dL for Control1 and 4.23 ~ 4.57 ng/dL for Control2, while the result of two-point calibration curve test shows ranges of 0.61 ~ 0.75 ng/dL for Control1 and 3.88 ~ 5.71 ng/dL for Control2. For TSH, the CV% of the normal test for Control1, Control2 and Control3 are 10.5, 3.3 and 3.6 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 12.4, 8.2 and 5.1 respectively. The result shows an outstanding correlation of TSH: y = 0.9985x - 0.0459 $R^2=0.9986$. For FT4, the CV% of the normal test for Control1 and Control2 are 0.70 and 0.71 respectively, while the CV% of the two-point calibration curve test for Control1 and Control1 are 8.7 and 16.2 respectively. The result shows an outstanding correlation of FT4: y = 1.2674x - 0.1133 $R^2=0.9824$. Conclusion The two-point calibration curve can be efficiently applied for TSH in cases where the number of test samples is not large, since the number of samples to be re-tested increases when the result is abnormal from the calibration curve. The two-point calibration curve test should not be applied for FT4 where the results do not consistently comply with the quality assessment range. Depending on how the two-point calibration curve is applied, up to 5 test tubes can be conserved per test, and the reduced time for reagent dispensing is anticipated to have a positive effect on the TAT (turnaround time).

  • PDF

원자간력 현미경의 자율교정법 (New Calibration Methods for improving the Accuracy of AFM)

  • 권현규;고영채
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.48-52
    • /
    • 2001
  • In this paper presents an accurate AFM used that is free from the Z-directional distortion of a servo actuator is described. Two mathematical correction methods by the in-situ self-calibrationare employed in this AFM. One is the method by the integration, and the other is the method by inverse function of the calibration curve. The in situ self-calibration method by the integration, the derivative of the calibration curve function of the PZT actuator is calculated from the profile measurement data sets which are obtained by repeating measurements after a small Z-directional shift. Input displacement at each sampling point is approximately estimated first by using a straight calibration line. The derivative is integrated with reference to the approximate input to obtain the approximate calibration curve. Then the approximation of the input value of each sampling point is improved using the obtained calibration curve. Next the integral of the derivative is improved using the newly estimated input values. As a result of repeating these improving process, the calibration curve converges to the correct one, and the distortion of the AFM image can be corrected. In the in situ self-calibration through evaluating the inverse function of the calibration curve, the profile measurement data sets were used during the data processing technique. Principles and experimental results of the two methods are presented.

  • PDF

휴대용 혈중pH 측정시스템의 구현 (Development of Portable System for Measuring pH in Blood)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

저가의 머신 비전 카메라를 이용한 2차원 진동의 측정 및 교정 (Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera)

  • 김서우;이정권
    • 한국음향학회지
    • /
    • 제37권2호
    • /
    • pp.99-109
    • /
    • 2018
  • 현존하는 진동 측정 센서는 정밀도 면에서는 대부분의 진동을 측정하기에 충분하나, 센서 한 개로 하나의 지점이나 방향에 한정하여 측정할 수밖에 없다는 단점을 갖고 있다. 반면 카메라의 경우, 정밀도나 측정 가능한 주파수 영역의 면에서는 다소 불리하지만, 한 번에 광범위한 영역의 진동을 측정할 수 있고 가격 면에서 유리하며 다자유도의 진동을 동시에 측정할 수 있다는 큰 장점을 갖고 있다. 본 연구에서는 저가의 머신 비전 카메라가 진동 측정 센서로서 어느 정도의 오차 범위 내에서 진동을 측정할 수 있는지 알아본 후, 실제 외팔보의 진동을 측정하였다. 카메라의 2차원 평면 이미지는 두 방향의 직선 운동과 한 방향의 회전 운동을 나타낼 수 있다. 먼저 단일 점의 진동을 카메라로 측정하고, LDV(Laser Doppler Vibrometer) 측정을 기준으로 한 카메라 측정의 오차를 실험적으로 교정하였다. 다음으로 다중점의 진동을 한 번에 측정하여 회전 진동과 외팔보 전체 형상의 진동을 측정하였다. 외팔보 전체 형상 진동은 주파수와 시간 영역 모두에 대하여 분석하였다.