• 제목/요약/키워드: Two-dimensional ultrasonography

검색결과 10건 처리시간 0.026초

Sonographic renal length and volume of normal Thai children versus their Chinese and Western counterparts

  • Rongviriyapanich, Chantima;Sakunchit, Thanarat;Sudla, Chirawat;Mungkung, Supamas;Pongnapang, Napapong;Yeong, Chai Hong
    • Clinical and Experimental Pediatrics
    • /
    • 제63권12호
    • /
    • pp.491-498
    • /
    • 2020
  • Background: Renal size is an important indicator in the diagnosis of renal diseases and urinary tract infections in children. Purpose: The purpose of this study is twofold. First, it aimed to measure the renal length and calculate the renal volume of normal Thai children using 2-dimensional ultrasonography (2D-US) and study their correlations with somatic parameters. Second, it aimed to compare the age-specific renal size of normal Thai children with the published data of their Western and Chinese counterparts. Methods: A total of 321 children (150 boys, 171 girls; age, 6-15 years) with a normal renal profile were prospectively recruited. All subjects underwent 2D-US by an experienced pediatric radiologist and the renal length, width, and depth were measured. Renal volume was calculated using the ellipsoid formula as recommended. The data were compared between the left and right kidneys, the sexes, and various somatic parameters. The age-specific renal lengths were compared using a nomogram derived from a Western cohort that is currently referred by many Thailand hospitals, while the renal volumes were compared with the published data of a Chinese cohort. Results: No statistically significant difference (P<0.05) was found between sexes or the right and left kidneys. The renal sizes had strong correlations with height, weight, body surface area, and age but not with body mass index. The renal length of the Thai children was moderately correlated (r=0.59) with that of the Western cohort, while the age-specific renal volume was significantly smaller (P<0.05) than that of the Chinese children. Conclusion: Therefore, we concluded that the age-specific renal length and volume obtained by 2D-US would vary between children in different regions and may not be suitably used as an international standard for diagnosis, although further studies may be needed to confirm our findings.

Situs inversus totalis in a dog with splenic marginal zone lymphoma

  • Choi, Sooyoung;Kim, Heesu;Lee, Kija;Park, Inchul
    • 한국동물위생학회지
    • /
    • 제41권4호
    • /
    • pp.281-285
    • /
    • 2018
  • An 11-year-old intact male mixed-breed dog was referred for evaluation of a splenic mass. On radiographs, the cardiac apex, stomach, and head of the spleen were on the right and the descending colon was on the left of the midline. In addition, the left kidney was located more cranially than the right kidney. Standard two-dimensional echocardiographic images were obtained from each inverted left and right parasternal windows. Furthermore, the spleen was observed on the right side and a splenic mass was found on the splenic tail. Based on the radiographic and ultrasonographic characteristics of the patient, a diagnosis of situs inversus totalis (SIT) and a splenic mass was made, and splenic resection was performed successfully with no unexpected complications. The splenic mass was confirmed histopathologically as being marginal zone lymphoma (MZL). This report describes a dog with SIT and splenic MZL.

3마리의 개에서 발생한 단일 간외성 문맥전신 단락 증례 (Single Extrahepatic Portosystemic Shunt in 3 Dogs: CT Findings and Progress)

  • 이희천;지창무;문종현;조규완;김영기;강병택;정동인
    • 한국임상수의학회지
    • /
    • 제29권6호
    • /
    • pp.488-493
    • /
    • 2012
  • 두 마리의 말티즈견 (2살 중성화 암컷, 4개월 암컷)과 한 마리의 페키니즈견 (10살 수컷)이 구토, 식욕부진, 두위하강과 침흘림 등의 증상으로 내원하였다. 신체검사, 혈액검사, 방사선검사, 초음파, 컴퓨터단층촬영이 진단을 위해 실시되었다. 실험실 검사에서 높은 간수치, 담즙산 수치, 암모니아 농도가 세 마리 모두에서 확인되었다. 두 마리의 환축에서 방사선검사 상 소간증이 확인되었다.복부 초음파 검사에서 세 마리 모두 문맥전신 단락이 많이 의심되어 컴퓨터단층촬영을 실시하였고, 그 결과 모두 단일 간외성 문맥전신 단락으로 확인되었다. 진단 후 세마리는 모두 수술적인 방법을 통해 단락 혈관에 아메로이드 링을 적용하였다. 본 증례보고는 세 마리의 개에서 발생한 단일 간외성 문맥전신 단락 증례에 대한 임상적, 영상학적인 특징들을 잘 나타내고 있으며, 컴퓨터단층촬영이 문맥전신단락의 정확한 진단을 위해 유용한 진단기법임을 잘 나타내고 있다.

Correlating two-dimensional shear wave elastography of acute pancreatitis with Spec cPL in dogs

  • Cho, Hyun;Yang, Seungwhwa;Suh, Gukhyun;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • 제23권5호
    • /
    • pp.79.1-79.11
    • /
    • 2022
  • Background: Pancreatitis is a common disease in which 37% of dogs had evidence of acute or chronic pancreatitis at necropsy. Although biopsy is still the gold standard to diagnose acute pancreatitis, clinical data including ultrasonographic findings and measurement of canine serum pancreatic lipase immunoreactivity (cPLI) are used in routine. However, it may be insufficient in the diagnostic approach to acute pancreatitis. Objectives: To evaluate the clinical diagnostic feasibility of two-dimensional shear wave elastography (2D SWE) on canine acute pancreatitis for enhanced diagnostic confidence. Methods: 2D SWE was used to assess pancreatic stiffness and determine the correlation between pancreatic shear wave velocity (SWV) and Spec cPL concentration in 31 dogs with healthy pancreas and 10 dogs with acute pancreatitis. Results: The pancreatic SWV was significantly higher in the acute pancreatitis group (2.67 ± 0.20 m/s) than in the healthy pancreas group (2.30 ± 0.26 m/s; p < 0.05). The moderate positive correlation was found between the pancreatic SWV and Spec cPL concentration (95% confidence interval, 0.214-0.693; r = 0.489; p < 0.05). Conclusions: These results indicated that 2D SWE was feasible for assessing pancreatic stiffness in acute pancreatitis, and that pancreatic SWV using 2D SWE correlated with Spec cPL concentration. SWE could provide a quantitative measure of pancreatic stiffness, which can increase the accuracy of diagnosing acute pancreatitis in dogs. The 2D SWE can be used as a complementary imaging modality for diagnosing acute pancreatitis in dogs.

Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis

  • Dong Wook Kim;Chong Hyun Suh;Kyung Won Kim;Junhee Pyo;Chan Park;Seung Chai Jung
    • Korean Journal of Radiology
    • /
    • 제20권6호
    • /
    • pp.880-893
    • /
    • 2019
  • Objective: To assess the technical performance of two-dimensional shear wave elastography (2D-SWE) for measuring liver stiffness. Materials and Methods: The Ovid-MEDLINE and EMBASE databases were searched for studies reporting the technical performance of 2D-SWE, including concerns with technical failures, unreliable measurements, interobserver reliability, and/or intraobserver reliability, published until June 30, 2018. The pooled proportion of technical failure and unreliable measurements was calculated using meta-analytic pooling via the random-effects model and inverse variance method for calculating weights. Subgroup analyses were performed to explore potential causes of heterogeneity. The pooled intraclass correlation coefficients (ICCs) for interobserver and intraobserver reliability were calculated using the Hedges-Olkin method with Fisher's Z transformation of the correlation coefficient. Results: The search yielded 34 articles. From 20 2D-SWE studies including 6196 patients, the pooled proportion of technical failure was 2.3% (95% confidence interval [CI], 1.3-3.9%). The pooled proportion of unreliable measurements from 20 studies including 6961 patients was 7.5% (95% CI, 4.7-11.7%). In the subgroup analyses, studies conducting more than three measurements showed fewer unreliable measurements than did those with three measurements or less, but no intergroup difference was found in technical failure. The pooled ICCs for interobserver reliability (from 10 studies including 517 patients) and intraobserver reliability (from 7 studies including 679 patients) were 0.87 (95% CI, 0.82-0.90) and 0.93 (95% CI, 0.89-0.95), respectively, suggesting good to excellent reliability. Conclusion: 2D-SWE shows good technical performance for assessing liver stiffness, with high technical success and reliability. Future studies should establish the quality criteria and optimal number of measurements.

Use of real-time ultrasound imaging for biofeedback of diaphragm motion during normal breathing in healthy subjects

  • Cho, Ji-Eun;Hwang, Dal-Yeon;Hahn, Joohee;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권3호
    • /
    • pp.95-101
    • /
    • 2018
  • Objective: To determine if the provision of visual biofeedback using real-time rehabilitative ultrasound imaging (RUSI) enhances the acquisition and retention of diaphragm muscle recruitment during exercise. Design: Two group pretest posttest design. Methods: Thirty healthy subjects were randomly assigned to the verbal feedback group (VG, n=15) or the visual and verbal feedback group (VVG, n=15). The VG performed breathing exercises 10 times with verbal feedback, and the VVG also performed breathing exercises 10 times with verbal feedback and visual feedback with the use of RUSI to measure changes in diaphragm thickness (DT). For DT, the mid-axillary lines between ribs 8 and 9 on both sides were measured in standing, and then the chest wall was perpendicularly illuminated using a linear transducer with the patients in supine to observe the region between rib 8 and 9 and to obtain 2-dimensional images. DT was measured as the distance between the two parallel lines that appeared bright in the middle of the pleura and the peritoneum. After one week, three repetitions (follow-up session) were performed to confirm retention effects. Intra- and between- group percent changes in diaphragm muscle thickness were assessed. Results: In the VVG, the intervention value had a medium effect size compared to the baseline value, but the follow-up value decreased to a small effect size. In the between-group comparisons, during the intervention session, the VVG showed no significant effect on percent change of DT but had a medium effect size compared to the VG (p=0.050, Cohen's d=0.764). During the follow-up session, retention effect did not persist (p=0.311, Cohen's d=0.381). Conclusions: RUSI can be used to provide visual biofeedback and improve performance and retention in the ability to activate the diaphragm muscle in healthy subjects. Future research needs to establish a protocol for respiratory intervention to maintain the effect of diaphragmatic breathing training using RUSI with visual feedback.

Two-Dimensional-Shear Wave Elastography with a Propagation Map: Prospective Evaluation of Liver Fibrosis Using Histopathology as the Reference Standard

  • Dong Ho Lee;Eun Sun Lee;Jae Young Lee;Jae Seok Bae;Haeryoung Kim;Kyung Bun Lee;Su Jong Yu;Eun Ju Cho;Jeong-Hoon Lee;Young Youn Cho;Joon Koo Han;Byung Ihn Choi
    • Korean Journal of Radiology
    • /
    • 제21권12호
    • /
    • pp.1317-1325
    • /
    • 2020
  • Objective: The aim of this study was to prospectively evaluate whether liver stiffness (LS) assessments, obtained by two-dimensional (2D)-shear wave elastography (SWE) with a propagation map, can evaluate liver fibrosis stage using histopathology as the reference standard. Materials and Methods: We prospectively enrolled 123 patients who had undergone percutaneous liver biopsy from two tertiary referral hospitals. All patients underwent 2D-SWE examination prior to biopsy, and LS values (kilopascal [kPa]) were obtained. On histopathologic examination, fibrosis stage (F0-F4) and necroinflammatory activity grade (A0-A4) were assessed. Multivariate linear regression analysis was performed to determine the significant factors affecting the LS value. The diagnostic performance of the LS value for staging fibrosis was assessed using receiver operating characteristic (ROC) analysis, and the optimal cut-off value was determined by the Youden index. Results: Reliable measurements of LS values were obtained in 114 patients (92.7%, 114/123). LS values obtained from 2D-SWE with the propagation map positively correlated with the progression of liver fibrosis reported from histopathology (p < 0.001). According to the multivariate linear regression analysis, fibrosis stage was the only factor significantly associated with LS (p < 0.001). The area under the ROC curve of LS from 2D-SWE with the propagation map was 0.773, 0.865, 0.946, and 0.950 for detecting F ≥ 1, F ≥ 2, F ≥ 3, and F = 4, respectively. The optimal cut-off LS values were 5.4, 7.8, 9.4, and 12.2 kPa for F ≥ 1, F ≥ 2, F ≥ 3, and F = 4, respectively. The corresponding sensitivity and specificity of the LS value for detecting cirrhosis were 90.9% and 88.4%, respectively. Conclusion: The LS value obtained from 2D-SWE with a propagation map provides excellent diagnostic performance in evaluating liver fibrosis stage, determined by histopathology.

Preliminary study on the effects of pergolide on left ventricular function in the horses with pituitary pars intermedia dysfunction

  • Gehlen, Heidrun;Fisch, Judith;Merle, Roswitha;Trachsel, Dagmar S.
    • Journal of Veterinary Science
    • /
    • 제22권5호
    • /
    • pp.64.1-64.12
    • /
    • 2021
  • Background: Pituitary pars intermedia dysfunction (PPID), a neurodegenerative disease leading to reduced dopamine production, is a common disease in aged horses. The treatment is based on administration of the dopamine agonist pergolide. This drug has been related to valvular fibrosis in humans, but the cardiovascular effect of this drug has not yet been investigated in horses. Objectives: To determine whether pergolide induces valvular disease in horses or affects the cardiac function. Methods: Standard, tissue Doppler (TDE) and two-dimensional speckle tracking (STE) echocardiography were performed in horses with diagnosed PPID based on adrenocorticotropic hormone dosage. Measurements taken in horses treated with pergolide were compared with those from untreated horses with nonparametric t-tests. Furthermore, measurements from follow-up examinations performed at least three months after the initial exam were compared with a Wilcoxon signed rank test for repeated measurements in each group. Results: Twenty-three horses were included. None of the 12 horses under treatment developed valvular regurgitation. Furthermore, no differences in the measurements of the left ventricular systolic or diastolic function could be seen between the group of horses with treatment and those without treatment. Measurements taken in the follow-up exam did not differ compared to those taken in the initial exam in both groups. Conclusions: No changes of the left ventricular function assessed by TDE and STE could be shown in a small population of horses with confirmed PPID. Treatment with pergolide did not affect the ventricular function nor induce valvular disease.

조파저항에서의 Neumann-Kelvin 문제에 대한 연구 (A Study on the Neumann-Kelvin Problem of the Wave Resistance)

  • 김인철
    • 수산해양기술연구
    • /
    • 제21권2호
    • /
    • pp.131-136
    • /
    • 1985
  • 코너에서의 특이점이 weak 표면 특이점이라면, 반잠수 반원에 대한 Neumann-Kelvin 문제는 코너에서 속도가 유계인 한 개의 최소특이해를 가진다. 그러나 왜 유계인 조건이 코너에서 부과되어야 하는가 하는 명백한 물리적 이유는 없다. 코너는 정체점이 되고 여기서 섭동속도는 전진속도와 같다. 그리고 코너에서의 선형화는 타당하지 않다. 그러나 우리는 이러한 것을 무시하고 코너에서 이 점을 가져야만 한다고 제안한다. 따라서 이것이 코너에서 약하거나 강한 특이점을 가지는 섭동방정식의 해를 찾기 위한 적당한 이유이다. 그러나 어떤 특이점이 적당한가를 결정하는 명확한 방법은 없다. Ursell은 그의 연구에서 (19)식의 p와 q를 0으로 두어 유일해를 결정하기도 하였다. Suzuki는 자유표면에 대하여 에너지 보존을 취하여 유일해를 확정시키는 부가적인 조건을 제시하기도 하였다. G (ξ,η;x, y)는 y>0일 때 (x, y)에서 소스를 나타내며, 실제로 G (ξ,η;a, 0)는 weak 표면특이점이다. 최소특이해에 대한 표현은 (11)로부터 추론할 수 있고 각각의 코너에서 불연속 weak 표면특이점과 함께 소스의 연속적인 분포로 구성된다. Maruo는 세장체 이론의 적응으로부터 유도된 근사방법을 소개하였는데 이것은 Neumann-Kelvin 문제의 Kernel 함수에 대한 근사와 기본적으로 같다. 비록 왜 최소특이해가 2차원에서 택해져야 하는가에 대한 명확한 물리적인 이유는 없더라 해도, 어떻게 상응하는 유계조건을 3차원에도 적용할 수 있는가 하는 것이 최근 연구과제 중의 하나다. Ursell의 연구에 의한 경험은 앞으로 완전한 비점성 3차원 문제의 취급에 사용될 것이고, Maruo의 세장선 근사와는 다른 방법으로 3차원 Neumann-Kelvin 문제를 해석할 수 있을 것이다.의 수는 오히려 약간 증가하는 것으로 보이며, 고농도처리시 이들 값이 다시 감소하는 것은 Chain들의 운동이 급격해지면서 일부 비정 chain들이 절단되어서 결과적으로 T.M. 및 T.T.M.의 수는 오히려 약간 증가하는 것으로 보이며, 고농도처리시 이들 값이 다시 감소하는 것은 Chain들의 운동이 급격해지면서 일부 비정 Chain들이 절단되어서 결과적으로 T.M. 및 T.T.M.의 수가 감소하기 때문이라 생각되었다.각되었다.n 4 cases by ultrasonography. And ultrasonography could not reveal collaterals, arteriovenous shunt and thread and streaks sign.순에 최대 밀도를 나타내였고, 10월 중순 부터는 채집할 수 없음을 알았다.위분지 이상에서 3%로 자엽절 2분지의 비중이 특히 컸다.스 접종 8일 후의 중장원동세포내에서 A형 및 B형 봉입체가 형성되었음을 확인하였다. 10. FV감염 중장조직세포의 전자현미경 관찰에서는 바이러스 접종 5일 후에 배상세포의 'cytoplasmic wall'이 비대해지고 그 내부에 virus-specific vesicle이 형성되었으며, 바이러스 접종 8일 후에는 virus-specific vesicle, 바이러스 입자, linear structure, tubular structure 및 전자밀도가 높은 matrix 등의 바이러스 감염에 대한 특이적인 구조물이 배상세포의 세포질에서 관찰되었으며, microvilli내에서 바이러스 입자의 존재도 확정되었다. 특히 virus-specific vesicle 주위에서는 전자밀도가 높은 구형의 바이러스 입자 유사체가 관찰되었는데, 이것은 virus-specific vesicle 주위에서 바이러스 조립이 일어나는 것을 추정된다

  • PDF

Radiomics를 이용한 1 cm 이상의 갑상선 유두암의 초음파 영상 분석: 림프절 전이 예측을 위한 잠재적인 바이오마커 (Radiomics Analysis of Gray-Scale Ultrasonographic Images of Papillary Thyroid Carcinoma > 1 cm: Potential Biomarker for the Prediction of Lymph Node Metastasis)

  • 정현정;한경화;이은정;윤정현;박영진;이민아;조은;곽진영
    • 대한영상의학회지
    • /
    • 제84권1호
    • /
    • pp.185-196
    • /
    • 2023
  • 목적 갑상선 유두암 환자에서 림프절 전이를 예측할 수 있는 잠재적인 바이오마커를 개발하기 위해 초음파 영상에 대한 radiomics를 조사하는 것이다. 대상과 방법 2013년 8월부터 2014년 5월까지 431명의 환자가 연구에 포함되었고 통계 소프트웨어를 사용하여 훈련 및 검증 세트로 구분되었다. 총 730개의 radiomics 특징이 자동으로 추출되었다. 훈련 데이터 세트에서 가장 예측 가능한 특징을 선택하기 위해 최소 절대 수축 및 선택 연산자가 사용되었다. 결과 Radiomics 점수는 림프절 전이와 관련이 있었다(p < 0.001). 림프절 전이는 젊은 연령(p = 0.007) 및 더 큰 종양 크기(p = 0.007)와 같은 다른 임상 변수와도 관련이 있었다. 수신자 조작 특성 곡선 하 면적 결과 값은 훈련 세트의 경우 0.687 (95% 신뢰 구간: 0.616-0.759), 검증 세트의 경우 0.650 (95% 신뢰 구간: 0.575-0.726)이었다. 결론 본 연구 결과는 초음파 영상 기반의 radiomics가 papillary thyroid carcinoma 환자에서 경부 림프절 전이를 예측하고 바이오마커로 작용할 가능성을 보여주었다.