• 제목/요약/키워드: Two-dimensional imaging

검색결과 399건 처리시간 0.028초

Three Dimensional Imaging Using Wavelets

  • Lee, Kyeong-Eun
    • Journal of the Korean Data and Information Science Society
    • /
    • 제15권3호
    • /
    • pp.695-706
    • /
    • 2004
  • The use of wavelets in three-dimensional imaging is reviewed with an example. The insufficiencies of direct two-dimensional processing is showed as a major motivating factor behind using wavelets for three-dimensional imaging. Different wavelet algorithms are used, and these are compared with the direct two-dimensional approach as well as with each other.

  • PDF

Evaluation of Fabric Pilling Using Hybrid Imaging Methods

  • Kim Sung-Min;Park Chang-Kyu
    • Fibers and Polymers
    • /
    • 제7권1호
    • /
    • pp.57-61
    • /
    • 2006
  • A study has been made on the quantification and evaluation of fabric pilling using two-dimensional and three-dimensional hybrid imaging methods. Two-dimensional imaging method was good for some samples while three-dimensional measurement method for others, according to the properties of their base fabric. Various image processing techniques as well as three-dimensional data processing algorithms were applied for the extraction of pills from measured data and a series of shape parameters have been defined for the objective evaluation of fabric pilling. An evaluation criterion that is compatible with the conventional evaluation method has been proposed by applying the new evaluation method to the current photographic standards.

Computational Implementation of Asymmetric Integral Imaging by Use of Two Crossed Lenticular Sheets

  • Shin, Dong-Hak;Cho, Myung-Jin;Kim, Eun-Soo
    • ETRI Journal
    • /
    • 제27권3호
    • /
    • pp.289-293
    • /
    • 2005
  • We propose an asymmetric integral imaging method to adjust the resolution and depth of a three-dimensional image. Our method is obtained by use of two lenticular sheets with different pitches fabricated under the same F/#. The asymmetric integral imaging is the generalized version of integral imaging, including both conventional integral imaging and one-dimensional integral imaging. We present experimental results to test and verify the performance of our method computationally.

  • PDF

An improved 2D/3D convertible integral imaging with two parallel display devices

  • Choi, Hee-Jin;Park, Jae-Hyeung;Kim, Joo-Hwan;Cho, Seong-Woo;Lee, Byoung-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.46-49
    • /
    • 2005
  • In this paper, a novel 2D/3D convertible display system based on integral imaging is proposed. Combining two liquid crystal display panels with integral imaging, it is possible to convert the display between two-dimensional mode and three-dimensional mode without mechanical movement. The proposed method is proven by preliminary experiments.

  • PDF

Three-dimensional imaging modalities in endodontics

  • Mao, Teresa;Neelakantan, Prasanna
    • Imaging Science in Dentistry
    • /
    • 제44권3호
    • /
    • pp.177-183
    • /
    • 2014
  • Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of periradicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

Oroantral communication, its causes, complications, treatments and radiographic features: A pictorial review

  • Shahrour, Rama;Shah, Priya;Withana, Thimanthi;Jung, Jennifer;Syed, Ali Z
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.307-311
    • /
    • 2021
  • Purpose: An oroantral communication (OAC) is an abnormal space between the maxillary sinus and oral cavity. The causes, complications, treatment, and radiographic features of OAC in 2-dimensional and 3-dimensional imaging modalities are discussed. Materials and Methods: This pictorial review presents a broad spectrum of imaging findings of OAC. Representative radiographs depicting OAC were chosen from our database. PubMed was used to conduct a comprehensive literature search of OAC. Results: Characteristic features of OAC include discontinuity of the maxillary sinus floor, thickening of the maxillary sinus mucosa, or a combination of both. Two-dimensional imaging modalities are the method of choice for identifying discontinuities in the maxillary sinus floor. However, 3-dimensional imaging modalities are also essential for determining the status of soft tissue in the maxillary sinus. Conclusion: The integration of 2-dimensional and 3-dimensional imaging modalities is crucial for the correct diagnosis and comprehensive treatment of OAC. However, the diagnosis of OAC must be confirmed clinically to prevent unnecessary mental and financial burdens to patients.

기능성 편광필름을 이용한 2차원/3차원 전환가능 변형 집적 영상 시스템 (Two-dimensional / Three-dimensional convertible modified integral imaging system using functional polarizing film)

  • 송병섭;박순기;민성욱
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 창립 20주년기념 특별학술발표회
    • /
    • pp.6-7
    • /
    • 2009
  • We proposed the two-dimensional (2D) / three-dimensional (3D) convertible modified integral imaging system using functional polarizing film named $imazer^{TM}$, which transfer or scatter the incident light ray according to the polarizing direction of ray. When the incident light rays transfer to $imazer^{TM}$, the rays generate 3D image through the process of the modified integral imaging system. However, the scattered light rays generate 2D image through the simple backlight scheme when the incident rays are scattered by the film. The proposed method can be implemented the partial 3D display system without any mechanical movements. In this paper, we propose and verify our system using some basic experiments and its results.

  • PDF

밀리미터파 수동 이미정 시스템 연구 III (Studies on the millimeter-wave Passive Imaging System III)

  • 정민규;채연식;김순구;윤진섭;미즈노 코지;이진구
    • 대한전자공학회논문지TC
    • /
    • 제44권3호
    • /
    • pp.111-116
    • /
    • 2007
  • 이차원 이미징 배열소자를 갖는 밀리미터파 수동 이미징 시스템을 제작하였다. 이 이미징 시스템을 제작하기 위하여 하나의 기판에 페르미테이퍼 슬롯 안테나. 발룬, 저잡음 증폭기 검파기가 집적되어 있는 이미징 배열 소자를 개발하였다. 또한 $2\times2$의 이미징 배열소자가 배열된 시스템으로 사람의 밀리미터파 수동 이미지를 얻었다. 현재 실시간 35GHz 밀리미터파 수동 이미지 시스템 개발을 위한 이차원 배열 소자를 개발 중에 있다. 제작된 이차원 이미징 배열소자를 갖는 밀리미터파 수동 이미징 시스템을 바탕으로 밀리미터파 실시간 영상을 취득할 수 있는 밀리미터파 수동 이미징 시스템의 실현을 기대할 수 있게 되었다.

Characteristics of Viewing Zone in Multiview 3 Dimensional Imaging Systems

  • Son, Jung-Young;Saveljev, Vladmir V.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.427-432
    • /
    • 2003
  • In contact-type multiview 3 dimensional imaging systems, the optimum design parameters are not easily found because of difficulty in determining the size of viewing zone. Two factors related with the viewing zone, such as different view image patching and the widths of the viewing regions are discussed to explain the difficulty.

  • PDF

방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발 (Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device)

  • 진동식;김경령;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.