• Title/Summary/Keyword: Two-dimensional deviation

Search Result 133, Processing Time 0.022 seconds

Determination of midsagittal plane for evaluation of facial asymmetry using three-dimensional computed tomography

  • Kim, Tae-Young;Baik, Jee-Seon;Park, Joo-Young;Chae, Hwa-Sung;Huh, Kyung-Hoe;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.41 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • Purpose : The aim of the present study was to investigate the disagreement of cephalometric analysis depending on the reference determination of midsagittal plane on three-dimensional computed tomography. Materials and Methods : A total of 102 young women with class III dentofacial deformity were evaluated using three-dimensional computed tomography. The cranial and facial midsagittal planes were defined and the amounts of jaw deviation were calculated. The amounts of jaw deviation were compared with paired t-test (2-tailed) and Bland-Altman plot was drawn. Results : The landmark tracing were reproducible ($r{\ge}.978$). The jaws relative to the cranial midsagittal plane were 10-17 times more significantly deviated than to the facial midsagittal plane (P<.001). Bland-Altman plot demonstrated that the differences between the amounts of jaw deviation from two midsagittal planes were not normally distributed versus the average of the amounts of jaw deviation from two midsagittal planes. Conclusion : The cephalometric analyses of facial asymmetry were significantly inconsistent depending on the reference determination of midsagittal plane. The reference for midsagittal plane should be carefully determined in three-dimensional cephalometric analysis of facial asymmetry of patients with class III dentofacial deformity.

Comparison of the three-dimensional structures of mandibular condyles between adults with and without facial asymmetry: A retrospective study

  • Oh, Min-Hee;Kang, Sung-Ja;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.48 no.2
    • /
    • pp.73-80
    • /
    • 2018
  • Objective: This retrospective study compared the three-dimensional (3D) structure of mandibular condyles between adults with and without facial asymmetry, and whether it influences menton deviation. Methods: Sixty adult patients were classified into symmetry and asymmetry groups based on the menton deviation on postero-anterior radiographs. The right/left differences of 3D measurements were compared between the two groups, and measurements were compared separately on the right and left sides. The correlations between menton deviation and the right/left differences were analyzed. Results: The mediolateral dimension, neck length, condylar angles to the anteroposterior reference (PO) and midsagittal reference planes, and neck and head volumes showed significantly larger right/left differences in the asymmetry group compared to the symmetry group. Separate comparisons of the right and left sides between the two groups showed that the neck was significantly shorter and neck and head volumes were significantly smaller on the left side, which was deviated side in the asymmetry group. Pearson's correlation analysis showed significant positive correlations of menton deviation with right/left differences in neck length, condylar angle to the PO plane, and neck and head volumes in the asymmetry group. Conclusions: In individuals with facial asymmetry, menton deviation is associated with the right/left differences caused by a smaller condyle on the deviated side, particularly in neck length and neck and head volumes.

Estimation of the Water Surface Slope by the Flood Discharge with River Bend Curvature (하천 만곡률과 홍수량에 따른 수면경사도 산정)

  • Choi, Han-Kyu;Lee, Mun-Hee;Baek, Hyo-Sun
    • Journal of Industrial Technology
    • /
    • v.26 no.A
    • /
    • pp.129-137
    • /
    • 2006
  • In this research, we made a one and two-dimensional analysis of numerical data collected from the bend curvature of a bended river section. According to the result from the numerical analysis, the inflow & output angle caused a water level deviation which increased with an increase of the flood discharge. From the water level deviation of our two-dimensional numerical model, we obtained the maximum slope of 6,67% when the inflow and output angle was 105 degrees and the flood discharge was 500 CMS. As for the right side, the differences with the one-dimensional numerical model were reduced when the angle was more than $90^{\circ}$. As for the left side the differences were reduced when the angle was more than $105^{\circ}$. For a river with more than 90 degrees bend curvature, a hydraulic experiment would be more appropriate than a numerical analysis.

  • PDF

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

Compatibility inspection for the way for Decision about Bight Flow Profile of Standard River Design (하천설계기준의 만곡부 수면형 결정 방법에 대한 적용성 검증)

  • Choi, Han-Kuy;Che, Hong-Gi;Baek, Hyo-Sun
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.43-51
    • /
    • 2006
  • Through the result of calculating the deviation between the value calculated from two-dimensional number formula, one-dimensional number interpretation, and curving part water surface type calculation method, we could confirmed that the deviation is reduced more than 50% when we use curving part water surface type calculation method. Also it was confirmed that there occurs the reduction rate of maximum 59% as the result of comparing with one-dimensional number interpretation since the reduction rate of safe room height was 20%, in 500 CMS of flood water quantity when we planted the construction of levee by curving part water surface type calculation method. And therefore, we have confirmed that the curving water surface type calculation method can be used as a simple formula in rivers with water quantity less than 500 CMS that flows in and out in Jess than 90 degree angle.

  • PDF

A Study on the Actual Conditions of Sizing System and Grading Method - Focusing on Brands Preferred by Adolescent - (청소년 선호 브랜드의 사이즈 체계 및 그레이딩 실태 조사에 관한 연구)

  • Uh Mn-Kyung;Suh Mi-A
    • The Research Journal of the Costume Culture
    • /
    • v.13 no.4 s.57
    • /
    • pp.646-657
    • /
    • 2005
  • The purpose of this study was to analyze the problems of brands preferred by adolescents on sizing system and grading method and to provide a basic information for adolescent apparel manufacturers. Brands preffered by adolescents were obtained via a questionnaire from adolescents aged from 13 to 18 in Seoul and finally we selected upper 12 brands out of 20 brands they preffered. Also the graders of 12 brands were surveyed through direct interviews. The results indicated only 2 brands out of 12 brands(such as Adidas and Basic House) manufactured apparels for adolescents and most brands targeted customers in their early twenties as a main target market. As a results of researching the sizing system of 12 brands, women's apparel brands produced two sizes separately for upper and lower garments, unisex apparel brands produced garments in 4${\~}$8 sizes. For most of the brands, each size has a dimensional deviation on the same rate in all parts and 12 brands manufactured garments mainly with a dimensional deviation of 5cm in bust circumference and hip circumference.

  • PDF

Crack propagation and deviation in bi-materials under thermo-mechanical loading

  • Chama, Mourad;Boutabout, Benali;Lousdad, Abdelkader;Bensmain, Wafa;Bouiadjra, Bel Abbes Bachir
    • Structural Engineering and Mechanics
    • /
    • v.50 no.4
    • /
    • pp.441-457
    • /
    • 2014
  • This paper presents a finite element based numerical model to solve two dimensional bi-material problems. A bi-material beam consisting of two phase materials ceramic and metal is modelled by finite element method. The beam is subjected simultaneously to mechanical and thermal loadings. The main objective of this study is the analysis of crack deviation located in the brittle material near the interface. The effect of temperature gradient, the residual stresses and applied loads on crack initiation, propagation and deviation are examined and highlighted.

Numerical method for the strength of two-dimensional concrete struts

  • Yun, Y.M.
    • Computers and Concrete
    • /
    • v.28 no.6
    • /
    • pp.621-634
    • /
    • 2021
  • For the reliable strut-and-tie model (STM) design of disturbed regions of concrete members, structural designers must accurately determine the strength of concrete struts to check the strength conditions of a selected STM el and the anchorage of reinforcing bars in nodal zones. In this study, the author proposed a consistent numerical method for strut strength, applicable to all two-dimensional STMs. The proposed method includes the effects of a biaxial stress state associated with tensile strains in reinforcing bars crossing a strut, deviation angle between strut orientation and compressive principal stress flow, and degree of confinement provided by reinforcement. The author examined the method's validity through the STM prediction of the ultimate strengths of 517 reinforced concrete (RC) deep beams, 24 RC panels, and 258 RC corbels, all tested to failure.

A comparative study of the deviation of the menton on posteroanterior cephalograms and three-dimensional computed tomography

  • Lee, Hee Jin;Lee, Sungeun;Lee, Eun Joo;Song, In Ja;Kang, Byung-Cheol;Lee, Jae-Seo;Lim, Hoi-Jeong;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Purpose: Facial asymmetry has been measured by the severity of deviation of the menton (Me) on posteroanterior (PA) cephalograms and three-dimensional (3D) computed tomography (CT). This study aimed to compare PA cephalograms and 3D CT regarding the severity of Me deviation and the direction of the Me. Materials and Methods: PA cephalograms and 3D CT images of 35 patients who underwent orthognathic surgery (19 males and 16 females, with an average age of $22.1{\pm}3.3years$) were retrospectively reviewed in this study. By measuring the distance and direction of the Me from the midfacial reference line and the midsagittal plane in the cephalograms and 3D CT, respectively, the x-coordinates ($x_1$ and $x_2$) of the Me were obtained in each image. The difference between the x-coordinates was calculated and statistical analysis was performed to compare the severity of Me deviation and the direction of the Me in the two imaging modalities. Results: A statistically significant difference in the severity of Me deviation was found between the two imaging modalities (${\Delta}x=2.45{\pm}2.03mm$, p<0.05) using the one-sample t-test. Statistically significant agreement was observed in the presence of deviation (k=0.64, p<0.05) and in the severity of Me deviation (k=0.27, p<0.05). A difference in the direction of the Me was detected in three patients (8.6%). The severity of the Me deviation was found to vary according to the imaging modality in 16 patients (45.7%). Conclusion: The measurement of Me deviation may be different between PA cephalograms and 3D CT in some patients.

Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.