• Title/Summary/Keyword: Two-Finger technique

Search Result 51, Processing Time 0.022 seconds

Comparing the Effectiveness Between Typical Infant CPR method and Over-head CPR method : A Study of the Single-Person Rescuer Simulation Using a Manikin

  • Choi, Sung-Soo;Han, Seung-Tae;Yun, Seong-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.7
    • /
    • pp.151-157
    • /
    • 2020
  • This study is to find out the effectiveness by Infant CPR method of a single rescuer. It was conducted for 51 general public. And typical infant CPR method by a single rescuer and a new method, CPR with two thumb chest compressions wrapped in both hands over the head were compared. SPSS 22.0 was used as an analysis method and to compare the both CPR methods, Paired t-test was used. As a result of the study, the average chest compression depth(39.38±1.07 mm) by CPR with two thumb chest compressions wrapped in both hands over the head was significantly high(p<0.001). Ease of mouth-to-mouth resuscitation(p<0.001), convenience of CPR method(p<0.001), and finger pain level(p<0.001) had a significant difference. As for the preference of the CPR method, 80.4%(41 people) preferred CPR with two thumb chest compressions wrapped in both hands over the head. In this study, CPR with two thumb chest compressions wrapped in both hands over the head showed more effective results than typical CPR method. However, as a virtual study using mannequins, further research is needed to apply high-quality CPR methods to field.

Exploration of Curvature of Three Dimensional Convex Object by Active Touch of Robot Hand (로봇손의 능동접촉에 의한 3차원 볼록한 물체의 곡률탐사)

  • Choi, Hyouk-Ryeol;Kim, Jin-Ho;Oh, Sang-Rok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.130-137
    • /
    • 1999
  • In this paper we propose a method of determining the local curvature of a three dimensional convex object using the force and torque information obtained from the active touch of a robot hand. A technique for estimating two dimensional curvature of a convex object are introduced and the way of computing the three dimensional curvature from the two dimensional vurvatures is presented. Also, we develop an experimental system consisting of a finger and verify the effectiveness of the proposed method experimentally.

  • PDF

Evaluation of the Effect of Sedimentation Basin Structure on Hydrodynamic Behavior Using CFD (II): The Effect of Trough (CFD를 이용한 침전지 구조가 수리거동에 미치는 영향 평가(II): 트라프의 영향 중심으로)

  • Park, No-Suk;Lim, Jae-Lim;Lee, Sun-Ju;Kwon, Soon-Bum;Min, Jin-Hui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.758-766
    • /
    • 2005
  • This study was conducted to evaluate the effect of the transverse troughs on hydrodynamic behavior within the a certain full-scale sedimentation basin (flow rate/one basin; $10,000m^3/d$) using CFD simulation and ADV technique. In order to verify the CFD simulation, we measured the factual velocity at 36 points in the full-scale sedimentation basin, whose outlet structure is inadequate, with ADV technique. Both the CFD simulation and the ADV measurement results were in good accordance with each other. From the CFD simulation results of the existing basin, it was investigated that extreme upward flow occurs in the near of two transverse troughs. It was suspected that since the transverse troughs converted the open channel flow into the local closed pipe flow, the increased pressure in this local closed pipe flow region made the extreme upward flow. For solving this problems, it was suggested to modify transverse-typed launder into finger-typed launder and to install a longitudinal baffle in the center in this study. The CFD simulation results of all suggested amendments told us that the extreme upward flow, had occurred especially in the beneath of transverse troughs, was much less in the case of finger typed launder basin than that in the existing basin. Also, it was predicted that installing a longitudinal baffle made the fully developed flow which is more effective for sedimentation.

A Comparative Analysis between Several Crutch-Length-Estimation Techniques and Ideal Crutch Length (이상적인 목발 길이와 목발 길이 추정법들간의 비교)

  • Kim, Min-Jung;Park, Yun-Soo;Yi, Chung-Hwi;Kim, Hyun-Ae
    • Physical Therapy Korea
    • /
    • v.3 no.1
    • /
    • pp.24-31
    • /
    • 1996
  • The purpose of this study was to determine which of several crutch-fitting techniques best predicts ideal crutch length. Ideal crutch length is defined as the length of the crutch, including accessories, obtained during stance when the crutch tip is 6 inches (15.2 cm) lateral and 6 inches(15.2 cm) anterior to the fifth toe and the axillary pad is 2.5 inches(6.4 cm) below the axillary fold. Forty four volunteers were measured for crutches using each of the following methods:(1) 77% of actual height, (2) actual height minus 40.6 cm, (3) actual height minus 45.7 cm, (4) olecranon to opposite third finger tip, (5) olecranon to opposite fifth finger tip, (6) 77% of arm span, (7) arm span minus 40.6 cm, (8) anterior axillary fold to heel plus 5.1 cm, (9) anterior axillary fold to heel plus 10.2 cm, (10) ideal crutch length. Of the techniques studied, the two involving anterior axillary fold to heel were found to be good predictors: anterior axillary fold to heel plus 5.1 cm and anterior axillary fold to heel plus 10.2 cm. Finally, two additional length estimates were derived using linear regression analyses. These estimates provided the best overall predictors based on anterior axillary fold to heel and actual height.

  • PDF

Effect of suboccipital muscle inhibition and combination technique on the flexibility of hamstring in individuals with shortened hamstring (뒤통수밑근 억제기법과 조합기법이 넙다리뒤근 단축 대상자의 넙다리뒤근 유연성에 미치는 영향)

  • Kim, Tae-Hun;Goo, Bong-Oh;Yun, Sam-Won;Lee, Jeong-Hun
    • PNF and Movement
    • /
    • v.13 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • Purpose: The purpose of this study is to compare changes in the flexibility of hamstring muscles which are relaxed on suboccipital muscle through suboccipital muscle inhibition and combination technique. Methods: Thirty sample subjects (16 male and 14 female) were randomly divided into an experimental group (n=15) and a control group (n=15). 1. Suboccipital muscle inhibition: Suboccipital muscles of the patients were placed on a bed. The occipital region was placed on a therapist's fingers, and the posture was maintained for three minutes before remeasurement. 2. Treatment with combination technique (body bolster and wooden pillow): Wooden pillows were placed where the participants could relax the posterior arch of the atlas; additional body bolsters were also placed to avoid high pressure, and the treatment was maintained for three minutes before remeasurement. Results: There was a statistical difference in finger floor distance (FFD) and straight leg raise (SLR) results for those treated with SMI (P<0.05). There was no statistical difference in FFD and SLR results for those treated with the combination technique (P>0.05). Conclusion: Between the two intervention methods; the suboccipital muscle inhibition technique was more effective in increasing the flexibility of subjects with a shortened hamstring than was the combination technique.

MPEG-U-based Advanced User Interaction Interface Using Hand Posture Recognition

  • Han, Gukhee;Choi, Haechul
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.4
    • /
    • pp.267-273
    • /
    • 2016
  • Hand posture recognition is an important technique to enable a natural and familiar interface in the human-computer interaction (HCI) field. This paper introduces a hand posture recognition method using a depth camera. Moreover, the hand posture recognition method is incorporated with the Moving Picture Experts Group Rich Media User Interface (MPEG-U) Advanced User Interaction (AUI) Interface (MPEG-U part 2), which can provide a natural interface on a variety of devices. The proposed method initially detects positions and lengths of all fingers opened, and then recognizes the hand posture from the pose of one or two hands, as well as the number of fingers folded when a user presents a gesture representing a pattern in the AUI data format specified in MPEG-U part 2. The AUI interface represents a user's hand posture in the compliant MPEG-U schema structure. Experimental results demonstrate the performance of the hand posture recognition system and verified that the AUI interface is compatible with the MPEG-U standard.

Sutureless Laparoscopic Ovariectomy in Small Dogs Using Two 3-mm Portal Sites

  • Hyeon-Han Ku;Ho Hyun Kwak;Jun-Hyung Kim;Kyung-Mee Park;Heung Myong Woo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.319-325
    • /
    • 2022
  • Two-port laparoscopic ovariectomy (Lap-OVE) has been performed in small dogs, using 3-mm and 5-mm portal sites, and is associated with reduced surgical stress and postoperative pain. However, extension of the incision is often needed to extract the ovaries. In this study, we aimed to minimize invasiveness by using smaller-sized cannulas as well as a novel technique for ovary extraction. Lap-OVE was performed on six, healthy female dogs (range, 3 to 7.2 kg) using two 3-mm midline portals. The middle finger of a size M nitrile glove was cut at its base and sterilized preoperatively. The ovary was suspended at the body wall using a 1-0 blue nylon needle, and the ovarian pedicle and ligaments were transected using a 3-mm bipolar forceps. To facilitate the glove passing through the 3.9-mm port, it was turned inside out to expose the smooth inner surface, before being inserted into the abdominal cavity with an applicator. Both ovaries were placed inside, and the mouth of the glove was exteriorized through the port with a laparoscopic grasping forceps. The ovaries were morcellated inside the glove, using Adison-Brown tissue forceps and iris scissors, which enabled safe extraction without incision enlargement. Median incision lengths were 4.3 mm (3.5-mm cranial cannula) and 4.8 mm (3.9-mm caudal cannula). An advantage of this procedure was that there was no need for skin sutures. In conclusion, using our novel technique, sutureless Lap-OVE was possible in small dogs using two 3-mm portal sites without additional incision.

Comparative Study of Spiral Oblique Retinacular Ligament Reconstruction Techniques Using Either a Lateral Band or a Tendon Graft

  • Oh, Jae Yun;Kim, Jin Soo;Lee, Dong Chul;Yang, Jae Won;Ki, Sae Hwi;Jeon, Byung Joon;Roh, Si Young
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.773-778
    • /
    • 2013
  • Background In the management of mallet deformities, oblique retinacular ligament (ORL) reconstruction provides a mechanism for automatic distal interphalangeal (DIP) joint extension upon active proximal interphalangeal joint extension. The two variants of ORL reconstruction utilize either the lateral band or a free tendon graft. This study aims to compare these two surgical techniques and to assess any differences in functional outcome. As a secondary measure, the Mitek bone anchor and pull-in suture methods are compared. Methods A single-institutional retrospective review of ORL reconstruction was performed. The standard patient demographics, injury mechanism, type of ORL reconstruction, and pre/postoperative degree of extension lag were collected for the 27 cases identified. The cases were divided into lateral band (group A, n=15) and free tendon graft groups (group B, n=12). Group B was subdivided into the pull-in suture technique (B-I) and the Mitek bone anchor method (B-II). Results Overall, ORL reconstructions had improved the mean DIP extension lag by $10^{\circ}$ (P=0.027). Neither the reconstructive technique choice nor bone fixation method identified any statistically meaningful difference in functional outcome (P=0.51 and P=0.83, respectively). Soft-tissue injury was associated with $30.8^{\circ}$ of improvement in the extension lag. The most common complications were tendon adhesion and rupture. Conclusions The choice of the ORL reconstructive technique or the bone anchor method did not influence the primary functional outcome of extension lag in this study. Both lateral band and free tendon graft ORL reconstructions are valid treatment methods in the management of chronic mallet deformity.

Changes in Sensory Function After Transcranial Direct Current Stimulation on Primary Motor Cortex Area

  • Min, Dong-Ki
    • Physical Therapy Korea
    • /
    • v.21 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • Transcranial direct current stimulation (tDCS) is a neuromodulatory technique that delivers low-intensity direct current to cortical areas, thereby facilitating or inhibiting spontaneous neuronal activity. This study was designed to investigate changes in various sensory functions after tDCS. We conducted a single-center, single-blinded, randomized trial to determine the effect of a single session of tDCS with the current perception threshold (CPT) in 50 healthy volunteers. Nerve conduction studies were performed in relation to the median sensory and motor nerves on the dominant hand to discriminate peripheral nerve lesions. The subjects received anodal tDCS with 1 mA for 15 minutes under two different conditions, with 25 subjects in each groups: the conditions were as follows tDCS on the primary motor cortex (M1) and sham tDCS on M1. We recorded the parameters of the CPT a with Neurometer$^{(R)}$ at frequencies of 2000, 250, and 5 Hz in the dominant index finger to assess the tactile sense, fast pain and slow pain, respectively. In the test to measure CPT values of the M1 in the tDCS group, the values of the distal part of the distal interphalangeal joint of the second finger statistically increased in all of 2000 Hz (p=.000), 250 Hz (p=.002), and 5 Hz (p=.008). However, the values of the sham tDCS group decreased in all of 2000 Hz (p=.285), 250 Hz (p=.552), and 5 Hz (p=.062), and were not statistically significant. These results show that M1 anodal tDCS can modulate sensory perception and pain thresholds in healthy adult volunteers. The study suggests that tDCS may be a useful strategy for treating central neurogenic pain in rehabilitation medicine.

Vaginal Reconstruction with Laparoscopic-perineal Rectosigmoid Colpopoiesis in Mayer-Rokitansky-Kuster-Hauser Syndrome: A Case Report (Mayer-Rokitansky-Kuster-Hauser 증후군 환자에서 회음부 복강경하 직결장질성형술을 이용한 질의 재건: 증례보고)

  • Bae, Sung-Gun;Lee, Sang-Yun;Cho, Byung-Chae;Choi, Kyu-Seok
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.333-337
    • /
    • 2011
  • Purpose: Various operations have been proposed to compensate for congenital absence of the vagina using ileal or colonic interposition. These methods involve laparotomy, which shows postoperative complications such as long scar and delayed recovery. One case of neovagina reconstruction with laparoscopic rectosigmoid colpopoiesis in Mayer-Rokitansky-Kuster-Hauser syndrome is presented to avoid laparotomic complications. Methods: Laparoscopic surgery was performed in a 27-year-old MRKH syndrome patient. After a cruciate incision, blunt dissection through two-finger wide space was created between the bladder and the rectum. A 14-cm rectosigmoid segment vascularized by a branch of sigmoid artery was isolated by laparoscopy. The distal end was sutured with vaginal vestibule mucosa. A continuity of intestine was restored by circular end-to-end proximate curved intraluminal stapler CDH29$^{(R)}$ through perineal opening. Results: Total operation time was 4 hr 15 min. Normal walking and ingestion were possible within 3 days and 4 days after surgery. The hospital stay was 7 days and the patient was followed up for 6 months. The neovaginal introitus was wide enough for inserting two fingers, and there has been no narrowing of the neovagina on palpation as confirmed by vaginogram. The patient had functional self-lubricating neovagina without excessive mucous production or the need for routine dilation or unnoticeable scar. Conclusion: The successful result of this laparoscopic vaginal reconstruction technique with rectosigmoid segment suggests that this technique can be considered for the option of vaginal reconstruction in girls with the MRKH syndrome.