• 제목/요약/키워드: Two temperature model

검색결과 1,898건 처리시간 0.033초

유동에 의한 연층 확산에 관한 실험적 연구 (An experimental study of convective smoke filling)

  • 김명배;한용식
    • 한국화재소방학회논문지
    • /
    • 제11권3호
    • /
    • pp.3-14
    • /
    • 1997
  • An experimental investigation of smoke spread in a corridor is made using thermocouples and visualization technique with a laser beam sheet. A speed of smoke front under a ceiling is measured by thermocouple trees. Visualization of the ceiling jet formation and of smoke filling process is carried out to observe lowering of the smoke layer. From the results, a large-scale convective motion the corridor plays dominant roles for smoke spread from visualized photos together with temperature records. A circulating motion of fluid transports some smokes to some regions where its momentum is effective. It is therefore showed that the conventional concept of lowering smoke with two-layer zone model has some restrictions for the corridor because the lowering of smoke layer has been thought to be mass transport due to relatively small scale motion such as decrease of buoyancy, mass diffusion and momentum exchange.

  • PDF

Multi-dimensional seismic response control of offshore platform structures with viscoelastic dampers (I-Theoretical analysis)

  • He, Xiao-Yu;Li, Hong-Nan;Zhang, Jun
    • Structural Monitoring and Maintenance
    • /
    • 제3권2호
    • /
    • pp.157-174
    • /
    • 2016
  • Based on classical viscoelastic damper, a brand-new damper is designed by the change of simple construction to implement vibration control for both translational vibration and rotational vibration simultaneously. Theoretic analysis has been carried out on the restoring force model and the control parameters. Two improved models are presented to obtain high simulation precision. The influence of the size, shape of the viscoelastic material, the ambient temperature and the response frequency on the vibration control effect is analyzed. The numerical results show that the new type viscoelastic damper is capable of mitigating the multi-dimensional seismic response of offshore platform and the response control effect has complicated relations with aforementioned related factors.

A Study of the Evaporation Heat Transfer in Advanced Reactor Containment

  • Y. M. Kang;Park, G. C.
    • Nuclear Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.291-298
    • /
    • 1997
  • In advanced nuclear reactors, the passive containment cooling has been suggested to enhance the safety. The passive cooling has two mechanisms, air natural convection and oater cooling with evaporation. To confirm the coolability of PCCS, many works have been performed experimentally and numerically. In this study, the water cooling test was performed to obtain the evaporative heat transfer coefficients in a scaled don segment type PCCS facility which have same configuration with AP600 prototype containment. Air-steam mixture temperature and velocity, relative humidity and well heat flux are measured. The local steam mass flow rates through the vertical plate part of the facility are calculated from the measured data to obtain evaporative heat transfer coefficients. The measured evaporative heat transfer coefficients are compared with an analytical model which use a mass transfer coefficients. From the comparison, the predicted coefficients show good agreement with experimental data however, some discrepancies exist when the effect of wave motion is not considered. Finally, a new correlation on evaporative heat transfer coefficients are developed using the experimental values.

  • PDF

비친수성유기물질(HOC)로 오염된 토양의 정화를 위한 동전기-생물활성화공정의 개발

  • 양지원;김상준;박지연;이유진;기대정
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.326-329
    • /
    • 2003
  • When an electrokinetic process is applied to a HOC-contaminated soil, hybrid types combined with soil flushing, chemical oxidation, and bioremediation are generally used. Especially when the electrokinetic process is combined with bioremediation, the hybrid technology can solve several limits of bioremediation such as low microbial mobility, low soil temperature, and shortage of nutrients in subsurface circumstance. Because microbial surface is charged negatively, the microorganism moves from cathode to anode under electrical field. In this study, mixed culture mainly-consisted by Pseudomonas sp. was applied to remediate pentadecane-contaminated kaolinite with particle size less than 300${\mu}{\textrm}{m}$. This remediation system was named ‘electrokinetic bioaugmentation’ and consisted of model aquifer, electrode reservoirs, bioreactor, power supply, and pump. The mixed culture above 0.5 of optical density in bioreactor was supplied to two reservoirs and penetrated soil when the electric current was applied. To enhance the removal efficiency, the optimal medium composition, electric current, and voltage were investigated.

  • PDF

NASICON 고체전해질의 이온전도도 계산 (I) Mid-Na의 영향을 고려하지 않은 경우 (Computation of Ionic Conductivity in NASICON Solid Electrolytes (I) Conduction Paths with no Mid-Na Sites)

  • 최진삼;서양곤;강은태
    • 한국세라믹학회지
    • /
    • 제32권8호
    • /
    • pp.957-965
    • /
    • 1995
  • The ionic conductivityof NASICON solid electrolytes was simulated by using Monte Carlo Method (MCM) based on a hopping model as functions of temoperature and composition. Two conduction paths were used : jumping from Na1 to Na2 and jumping from Na1 to Na2 and jumping from Na2 to Na2. Vacancy availability factor, V was affected by composition, temperature and the conduction paths. For β"-Alumina, it was known that the minimum of charge correlation factor, fc appears at the composition, p=0.5, but there was not shown the minimum of fc for NASICON. When the NASICON composition, x, approaches 2.5, the curve of In σT vs. 1/T* was shown Arrhenius behavior and also In (VWfc) was a linear function of 1/T*. The results of simulations on the considered conduction paths didn't agree with the experimental results. Thus it will be necessary to include the another Na sites as mid-Na site on the conduction path to obtain the better results.

  • PDF

작업장 환기장치 최적화 유동 연구 (A Numerical Optimization Study on the Ventilation Flows in a Workshop)

  • 엄태인;장동순
    • 한국안전학회지
    • /
    • 제10권1호
    • /
    • pp.64-73
    • /
    • 1995
  • A preliminary study is performed in order to design an effective ventilation equipment for the control of possible pollutants in a workshop. To this end, the Patankar's SIMPLE methodology is used to investigate the flow characteristics of the contaminated thermal deflected jet which is encounted often in practical hood system. SIMPLE-Consistent algorithm is employed for the pressure-velocity coupling appeared in momentum equations. A two equation, k-$\varepsilon$ model is used for Reynolds stresses. The prediction data is compared well against the experimental results by Chang(1989). Considering the control of the wake due to its high turbulence together with the stagnant feature has been investigated in term of major parameters such as temperature and magnitude of the discharge velocity. Detailed discussions are made to reduce the size of the wake region which give rise to pollutant concentration stratification.

  • PDF

전기자장에 의한 혼상류의 제어에 관한 수치해석 (Numerical Analysis on the Control of Particle-laden Flow Using Electromagnetic Field)

  • 남성원;신산신일
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1996년도 춘계 학술대회논문집
    • /
    • pp.125-130
    • /
    • 1996
  • A numerical analysis is conducted on heat transfer and fluid flow of a plasma spraying process under the DC-RE hybrid electromagnetic field. Plasma flow is analyzed by using Eulerian approach and the equation of particle motion is simultaneously solved using a trajectory analysis with a lumped-heat-capacity model. Axisymmetric two dimensional electromagnetic fields governed by Maxwell's equations are solved based on a vector potential concept. The effects of the RF electromagnetic field on the temperature and velocity fields of the turbulent plasma flow are clarified. Control characteristics of phase changes and dispersed features of particles by applying the RF electromagnetic field are also clarified in an attempt to improve the plasma spraying process

  • PDF

Estimation of Heat Losses From the Receivers for Solar Energy Collecting System of Korea Institute of Energy Research

  • Ryu, Siyoul;Seo, Taebeom
    • Journal of Mechanical Science and Technology
    • /
    • 제14권12호
    • /
    • pp.1403-1411
    • /
    • 2000
  • Heat losses from the receivers for a dish-type solar energy collecting system constructed at Korea Institute of Energy Research are analyzed. The Stine and McDonald's model is used to estimate the convection loss. The Net Radiation method and the Monte-Carlo method are used to calculate the radiation heat transfer rate from the inside surface of the receiver to the surroundings. Two different receivers are suggested here and the performances of the receivers are estimated and compared with each other based on the prediction of the amount of heat losses from the receivers. The effects of the receiver shape and the radiation properties of the surface on the thermal performance are investigated. The performance of Receiver I is better than that of Receiver II, and the amount of solar irradiation that is not captured by the captured by the receiver after being reflected by the concentrator becomes significant if the temperature of the working fluid is low.

  • PDF

자동차용 Halogen Lamp 의 수명 예측 (Lifetime Estimation of an Automotive Halogen Lamp)

  • 김충식;신승중;곽계달
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1259-1264
    • /
    • 2008
  • This paper presents an accelerated life test for burn out of tungsten filament of automotive halogen lamp. There are many failure modes and failure factors that associated with tungsten filament. But in this explain the dominant failure mode of tungsten filament is the bumout of the filament failure. At first, over voltage, high temperature, inrush current and vibration are selected as stress factors by using of two stage Quality Function Deploymeng(QFD). And we planed accelerated life test that has one factor(voltage) and three levels. By experiment it has absorbed that over voltage has an effect on the life of halogen lamp. Using ALTA programs, we estimated the common shpae parament of Weibull distribution, life-stress relationship and $B_{100p}$ life.

  • PDF

Computations of Losses and Temperatures in the Core Ends of a High Voltage Turbo-generator

  • Liu Yujing;Hjarne Stig
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.299-305
    • /
    • 2005
  • The work described in this paper is to investigate the additional iron losses and consequent temperatures in core ends of a turbo-generator wound with high voltage cables. Electromagnetic calculations are made with 3D FE models, which include the lamination material with anisotropic properties both in magnetic permeability and electric conductivity. The models also include the geometry of the stator teeth and eventually the axial steps designated to reduce the core end losses. The 3D model of the rotor consists of field windings with straight in-slot parts and end windings. The thermal models are simplified into two dimensions and include the heat sources dumped from the 3D electromagnetic solutions. The influences of power factor on additional iron losses are studied for this cable wound machine and conventional machines. The calculation results show that the additional iron losses can be reduced to about $15\%$ by introducing some small steps around the airgap corner of core ends.