• 제목/요약/키워드: Two electrodes

Search Result 903, Processing Time 0.033 seconds

EFFECTS OF ELECTRICAL STIMULATION ON THE NORMAL PERIODONTIUM (전기자극이 정상 치주조직에 미치는 영향)

  • Lim, Kyung-Seok;Kwon, Young-Hyuk;Lee, Man-sup;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.89-112
    • /
    • 2002
  • The earliest reports of the use of electrical energy to directly stimulate bone healing seem to be in 1853 from England, the techniques involved the introduction of direct current into the non-united fracture site percutaneously via metallic needles, with subsequent healing of the defect. One endpoint of the periodontal therapy is to generate structure lost by periodontal diseases. Several procedural advances may support regeneration of attachment, however, regeneration of alveolar bone does not occur consistently. Therefore, factors which stimulate bone repair are areas for research in periodontal reconstructive therapy. Effects of cytokines or growth factors on bone repair are examples of such areas. Another one is electrical current which occurs in bone naturally, so that such bone may be particularly susceptible to electrical therapy. The purposes of this study were to observe the effects of electrical stimulation on the normal periodontium, to determine whether the electricity is the useful means for periodontal regeneration or not. Forty rats weighted about 100 gram were used and divided into 4 groups, the first group, there was no electrical stimulation with the connection of electrodes only. In the second group, there was stimulated by the 10 mA during 10 minutes per a day, in the third group was stimulated by the 25 mA , and the fourth by the 50 mA. At 3, 5, 10 and 15 days post-appliance , two rats in each group were serially sacrificed. and the maxillae and the mandible processed to paraffin, and the specimens were prepared with Hematoxylin-Eosin stain for the light microscopic evaluation. The results of this study were as follows : 1. There was the distinct reversal line on the lingual alveolar crest, whereas a little changes in the labial alveolarcrest to the duration and amount of currents. 2. In 50 mA group, the cells were highly concentrated at the apex of anterior teeth, and was observed the necrotic tissue. In posterior root apex, the hypercementosis was appeared, and newly formed cementum layer has been increased continuously with the time. 3. The periodontal ligament fiber and Sharpey's fiber were arranged in order, and the bone trabeculae were increased as the experiment proceeded by, relatively the bone marrows were decreased. 4. In the pulp tissue, the blood vessels were increased with blood congestion in the experimetal specimens remarkably, and the dentinal tubules were obstructed . 5. The osteoblasts in alveolar bone proper had been showed highly activity, and also observed the formation of bone trabeculea. In the conclusion, it was suggested that the electrical stimulation has influence on the periodontium and the pulp tissue. However, there might be the injurious effects.

A Study on the Performance and Operation Limit of Electrodialysis Cell for HI Concentration (HI 농축에 대한 전기투석 셀의 성능 및 운전한계조건 연구)

  • Lee, Byung-Woo;Jeong, Seong-Uk;Cho, Won-Chul;Kang, Kyoung-Soo;Park, Chu-Sik;Bae, Ki-Kwang;Kim, Young-Ho;Kim, Chang-Hee
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.6
    • /
    • pp.749-758
    • /
    • 2011
  • The present work explores the performance and operation limit of electrodialysis cell for HI concentration in sulfur iodine thermochemical hydrogen production process, For this purpose, the electrodialysis cell was assembled with Nafion 117 as a PEM membrane and two activated carbon papers as the electrodes. HIx solution was prepared with composition of HI: $I_2$: $H_2O$ = 1: 0.5~2.5: 5.2 in molar ratio. The cell and its peripheral apparatus were placed in the specially designed convective oven in order to uniformly maintain the operation temperature. As operation temperature increased, the amount of water transport from anode to cathode increased, thus reducing HI molarity in catholyte. Meanwhile, the current efficiency was constant as about 90 %, irrespective of temperature change. The cell voltage increased with initial $I_2$ mole ratio as well as anolyte to catholyte mole ratio. Moreover the cell voltage overshot took place within 10 h cell operation, which is due to the $I_2$ precipitation inside the cell. From the analysis of $I_2$ mole ratio in the anolyte, it is noted that operation limit (in $I_2$ mole ratio) of the electrodialysis cell, arising from was measured to be 3.2, which is much lower than bulk solubility limit of 4.7.

Assessment of Regulatory Effect of Electro-acupuncture at Jogsamni($ST_{36}$), on Electrogastrography in Diabetic Patients with Gastric Dysrhythmia;A Case Series Study (위장 비율동성 당뇨환자에서 족삼리(足三里)($ST_{36}$) 전침처치의 위전도 조절 영향 사례군 연구)

  • Oh, Dal-Seok;Choi, Jun-Yong;Jung, So-Young;Shin, Mi-Suk;Kim, Ae-Ran;Kang, Kyung-Won;Kim, Jong-In;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.25 no.4
    • /
    • pp.95-103
    • /
    • 2008
  • Objectives : This study was to investigate the regulatory effect of electro-acupuncture on Jogsamni ($ST_{36}$) in bradygastric condition or gastroparesis which is a neuropathic complication of type 2 diabetes mellitus(T2DM), assessed using 4-channel electrogastrography (EGG). Methods : It was a case series study. Each patient was given electro-acupuncture(EA) one point, Jogsamni($ST_{36}$) or Gyeonu($LI_{15}$) bilaterally for thirty minutes with 2Hz bipolar square wave frequency and moderate intensity of stimulation. With attaching electrodes around stomach region throughout pre-acupuncture, acupuncture, and post-acupuncture session, these parameters were produced; percent rate of bradygastria power compared to sum of power in all kind of gastric rhythm(% bradygastria), dominant frequency(DF) and dominant power(DP). Parameter was analysed per each channel's variable change from pre-acupuncture session by paired t-test. Results : There was statistically significant decrease in % bradygastria parameters on one of the $ST_{36}$ treated patients from pre-acupuncture session and to post-acupuncture session(P=0.015, P=0.008 respectively). A marginal significant decrease of DP was shown in the other $ST_{36}$ treated patient from pre-acupuncture session through post-acupuncture session(P=0.049). Combined data of two $ST_{36}$ Treated patients showed that there was significant decrease of %bradygastria from pre-acupuncture session to acupuncture session(P=0.020), and was decrease of DP from pre-acupuncture session to post- acupuncture session(P=0.020). Conclusions : EA at $ST_{36}$ resulted in statistically significant decrease in %bradygastria and DP for dysrhythmic condition in T2DM gastroparesis patients. Considering this limited results, further study will be needed to elucidate the effect of multiple-acupuncture on gastric myoelectrical activities.

  • PDF

Effect of Electro-acupuncture on Regional Fat by Measuring Thigh Circumference (저주파 전침자극이 허벅지 둘레에 미치는 영향에 대한 연구)

  • Ahn, Soo-Jeong;Kim, Jeung-Shin;Shin, Hyun-Taeg;Kim, Yong-Suk;Lee, Kyung-Sub;Hwang, Deok-Sang
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.5 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Objectives: Although electro-acupuncture is being utilized to reduce weight in Korea, its usefulness in obesity management has not been fully evaluated yet. The objective of this study is to evaluate the effect of Electro-acupuncture on thigh circumference. Methods: 12 healthy volunteers participated in this study. We measured the circumference of both thighs, and treated the thicker one with transcutaneous electro-acupuncture at 8 acupoints, 10 times in total. The electrical parameters were : 1st step frequency set was at 15Hz and the treatment proceeded for 50 minutes, 2nd step at 50Hz for 10 minutes and at 3rd step the acupunctures were removed and electrodes were attached on the lower limb at 166Hz for 15 minutes. In order to evaluate the effect of the treatment, total body weight, percentage of body fat and thigh circumference were measured 4 times. Before the treatment, after 5th and 10th treatment and 1 month after completion of the whole treating procedure. Statistical significance(P<0.05) was determined using the Wilcoxon signed rank test. We did not control diet, exercise and lifestyle of the volunteers. Results: No significant change was shown in body weight after 10 times of treatment. Yet the thigh circumference of effect group significantly decreased after 5th treatment and 10th treatment. The circumference of control group that was not treated by electro-acupuncture significantly decreased too. At first, difference between the two thighs in circumference was obvious, but no difference was left after 10 times of treatments on the thicker thigh. Percentage of body fat was significantly decreased. 1 month after having completed the treatment, there was no significant difference of body weight, thigh circumferences and percentage of body fat. Conclusion: These results suggest that electro-acupuncture effectively regulates regional fat, body fat percentage and body shape.

  • PDF

Rheographic View of the Change in the Renal Blood Flow in Acute Hemorrhage (Rheogram으로 본 실혈시 신장혈액유통 변화)

  • Chang, Se-Gu;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.5 no.1
    • /
    • pp.59-69
    • /
    • 1971
  • Studies were undertaken on the changes in the renal blood flow by relating them with the alterations in the amplitudes in the rheogram of rabbits. The changing pattern of the electrical conductivity was recorded by means of the needle electrodes inserted into the kidney and the surrounding aluminium foil which was grounded. The Impedance Rheograph manufactured by the Narco Company was used. The small artifact which persisted after ligation of the renal vessels was subtracted from the value obtained in each pulsatile wave in the rheogram. The animals were nembutalized intravenously, 30 mg/kg. A plastic canule was inserted into the carotid artery and the arterial blood pressure was monitored continuously with the pressure transducer connected to the physiograph. Stepwise bleedings were performed on the animal. The first bleeding was between 13 to 18 ml in the amount, and it was folowed by consecutive hemorrhages, 5 or 10 ml each time. The total amount of bleeding was summed as much as 1.5-2% of the body weight. Two minutes fter each bleeding th arterial blood pressure, ECG and the rheogram were taken. That was the necessary time to obtain the stabilized picture of each parameter. After closing the bleeding process, the shed blood was retransfused into the animal and the response in the renal blood flow was observed as well as the arterial blood pressure. Particularly the presence or absence of the autoregulatory mechanism in the situation of the hemorrhage was also studied. The results obtained were as follows: 1. In 7 cases out of 22, that was about one third of the total number of experiments, the autoregulatory mechanism of the renal blood flow persisted even in acute hemorrhage, and the decreases in the renal blood flow were less than 10% of the control values even when the arterial blood pressure dropped to 66-87% of the original value obtained before the bleeding. 2. Because of the stepwise bleeding the exact blood pressure at which the renal blood flow reduced as much as one third of the control value could not be obtained. However, the results revealed that the approximate pressure, expressed as percentage of the control value, was 50-60% in 3 cases, 61-70% in 4 cases and 71-80% in 8 cases. In one case the decrease in the renal blood flow exceeded one third of the control value before the pressure dropped to 80% of the control. 3. In 19 cases the decreases in the renal blood flow exceeded one half of the control values by hemorrhage. Then the arterial blood pressure revealed less than 40% of the control value in 6-cases. In 2 cases the pressure was 51-60% of the control pressure. In 5 cases the range of bleed pressure was 61-70%, and in e remaining 6 cases the pressure ranged from 71 to 80% of e control value. 4. Out of 15 cases of retransfusion after definite decreases in the renal blood flow loller·ing the hemorrhage, 9 cases restored their renal blood flow. On the contrary 6 cases showed low values even when the shed blood was retransfused. 5. Theories concerning the mechanism of the autoregulation of the renal blood flow were reviewed for the purpose of explanation of the results obtained. However, there are much to be done before greater satisfaction

  • PDF

Short Term Outcomes and Prognostic Factors Based on Radiofrequency Thermocoagulation on Lumbar Medial Branches (요추 후지내측지에 대한 고주파열응고술의 단기 성적과 예후 인자)

  • Choi, Byung In;Kweon, Tae Dong;Park, Kyung Bae;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • v.20 no.2
    • /
    • pp.116-122
    • /
    • 2007
  • Background: Lumbar zygapophysial joints are a common source of chronic lower back pain and radiofrequency thermocoagulation (RF) of the medial branches (MB) has been shown to be effective at providing substantial pain relief for chronic low back pain. Therefore, we carried out this study to determine the short term outcomes and prognostic factors of RF on the MB of patients with lumbar facet syndrome. Methods: We performed RF in fourteen patients who showed greater than 80% pain relief up to three times after a diagnostic MB block was conducted using 0.3 ml of 0.5% bupivacaine. Using 10 cm curved electrodes with 10-mm active tip, a 60 second, $80^{\circ}C$ lesion was made after electrical stimulation at 50 Hz for sensory and 2 Hz for motor nerve testing. The degree of pain relief was then assessed after 2 weeks, and again after 3 months using a visual analog scale (VAS) and a four point Likert scale. The outcome was regarded as 'success' if at least a 50% reduction in the VAS was observed. Possible prognostic factors between the two groups were also evaluated Results: The success rate was 71.4% (10/14) after three months of follow-up. However, there were transient complications, such as neuritis like syndrome, in 4 patients. In addition, short symptom duration and low minimal voltage (< 0.4 V) for sensory stimulation were shown to be the relevant prognostic factors for a successful outcome. Conclusions: RF may be an alternative to repeated MB block or intraarticular injection for palliation of lumbar facet syndrome. For better outcomes, early diagnosis and strict patient selection should be coupled with efforts to avoid anatomically incorrect RF.

Determination of Complex Formation Constant of Sodium-Selective Ionophores in Solvent Polymeric Membranes (용매 고분자막 상에 고정된 나트륨 이온선택성 물질의 착물형성상수 결정)

  • Kang, Tae Young;Kim, Sung Bae;Oh, Hyon Joon;Han, Sang Hyun;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • The complex formation constants (${\beta}_{MLn}$) of potassium and various sodium-selective neutral carriers in solvent polymeric membranes have been determined using solvent polymeric membrane-based optodes and ion-selective electrodes (ISEs). Two different types of PVC-based membranes containing the H^+selective chromoionophore (ETH 5294) with and without a sodium ionophore (4-tert-bntylcalix[4]arenetetraacetic acid tetraethyl ester, ETH 2120, bis[(12-crown-4)methyl] dodecylmethylmalonate or monensin methyl ester) were prepared and their optical responses to either the changes in alkali metal cation (e.g., sodium and potassium) concentrations at a fixed pH (0.05 M Tris-HCl, pH 7.2) or varying pH at a fixed alkali metal cation concentration (0.1 M) were measured. The same type of membranes were also mounted in conventional electrode body and their potentiometric responses to varying pH at a fixed alkali metal cation concentration (0.1 M) were measured. The complex formation constants of the ligand could be calculated from the calibration plots of the relative absorbance vs. the activity ratios of cation and proton ($a_{M^+}/a_{H^+}$) and of the emf vs. pH. It was confirmed that the ratio values of the complex formation constants for the primary and interfering ions are closely related to the experimental selectivity coefficients of ISEs.

  • PDF

Pulsed Electric Fields: An Emerging Food Processing Technology-An Overview (PEF 처리에 의한 식품의 가공)

  • Jayaprakasha, H.M.;Yoon, Y.C.;Lee, S.K.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.871-878
    • /
    • 2004
  • Pulsed electric fields(PEF) technology is one of the latest nonthermal methods of food processing for obtaining safe and minimally processed foods. This technology can be effectively explored for obtaining safe food with minimum effect on nutritional, flavor, rheological and sensory qualities of food products. The process involves the application of high voltage(typically 20 ${\sim}$ 80 kv/cm) to foods placed between two electrodes. The mode of inactivation of microorganism; by PEP processing has been postulated in term; of electric breakdown and electroporation. The extent of destruction of microorganisms in PEF processing depends mainly on the electric field strength of the pulses and treatment time. For each cell types, a specific critical electric field strength and specific critical treatment time are required depending on the cell characteristics and the type and strength of the medium where they have been present. The effect also depends on the types of microorganisms and their phase of growth. A careful combination of processing parameters has to be selected for effective processing. The potential applications of PEF technology are numerous ranging from biotechnology to food preservation. With respect to food processing, it has already been established that, the technology is non-thermal in nature, economical and energy efficient, besides providing minimally processed foods. This article gives a brief overview of this technology for food processing applications.

Effects of Pd Addition Amount and Method on the Characteristics of SnO2 Semiconductor Thick Films for Alcohol Gas Sensors (Pd 첨가량 및 첨가방법이 알코올 센서용 SnO2 반도체 후막 특성에 미치는 영향 연구)

  • Kim, Jun-Hyung;Kim, Hyeong-Gwan;Lee, Ho-Nyun;Kim, Hyun-Jong;Lee, Hee-Chul
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.5
    • /
    • pp.411-420
    • /
    • 2017
  • In this paper, two methods of making the Pd-added $SnO_2$ ($Pd-SnO_2$) powder with pure tetragonal phase by the hydrazine method were suggested and compared in terms of crystal structure, surface morphology, and alcohol gas response. One of the addition methods is to use $PdCl_2$ as a Pd source, the other is to use Pd-based organic with oleylamine (OAM). When Pd concentration was increased from 0 to 5 wt%, the average grain size of $Pd-SnO_2$ made with Pd-OAM were decreased from 32 to 12 nm. In the case of using with $PdCl_2$, grain size of the $PdCl_2$ fell to less than 10 nm. However, agglomerated and extruded surface morphology was observed for the films with Pd addition over 4 wt%. The crack-free $Pd-SnO_2$ thick films were able to successfully fill the $30{\mu}m$ gap of patterned Pt electrodes by optimized ink dropping method. Also, the 2 wt% $Pd-SnO_2$ thick film made with PdCl2 showed gas responses ($R_{air}/R_{gas}$) of 3.7, 5.7 and 9.0 at alcohol concentrations of 10, 50 and 100 ppm, respectively. On the other hand, the prepared 3 wt% $Pd-SnO_2$ thick film with Pd-OAM exhibited very excellent responses of 3.4, 6.8 and 12.2 at the equivalent measurement conditions, respectively. The 3 wt% $Pd-SnO_2$ thick film with Pd-OAM has a specific surface area of $31.39m^2/g$.

Direct Imaging of Polarization-induced Charge Distribution and Domain Switching using TEM

  • O, Sang-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.99-99
    • /
    • 2013
  • In this talk, I will present two research works in progress, which are: i) mapping of piezoelectric polarization and associated charge density distribution in the heteroepitaxial InGaN/GaN multi-quantum well (MQW) structure of a light emitting diode (LED) by using inline electron holography and ii) in-situ observation of the polarization switching process of an ferroelectric Pb(Zr1-x,Tix)O3 (PZT) thin film capacitor under an applied electric field in transmission electron microscope (TEM). In the first part, I will show that strain as well as total charge density distributions can be mapped quantitatively across all the functional layers constituting a LED, including n-type GaN, InGaN/GaN MQWs, and p-type GaN with sub-nm spatial resolution (~0.8 nm) by using inline electron holography. The experimentally obtained strain maps were verified by comparison with finite element method simulations and confirmed that not only InGaN QWs (2.5 nm in thickness) but also GaN QBs (10 nm in thickness) in the MQW structure are strained complementary to accommodate the lattice misfit strain. Because of this complementary strain of GaN QBs, the strain gradient and also (piezoelectric) polarization gradient across the MQW changes more steeply than expected, resulting in more polarization charge density at the MQW interfaces than the typically expected value from the spontaneous polarization mismatch alone. By quantitative and comparative analysis of the total charge density map with the polarization charge map, we can clarify what extent of the polarization charges are compensated by the electrons supplied from the n-doped GaN QBs. Comparison with the simulated energy band diagrams with various screening parameters show that only 60% of the net polarization charges are compensated by the electrons from the GaN QBs, which results in the internal field of ~2.0 MV cm-1 across each pair of GaN/InGaN of the MQW structure. In the second part of my talk, I will present in-situ observations of the polarization switching process of a planar Ni/PZT/SrRuO3 capacitor using TEM. We observed the preferential, but asymmetric, nucleation and forward growth of switched c-domains at the PZT/electrode interfaces arising from the built-in electric field beneath each interface. The subsequent sideways growth was inhibited by the depolarization field due to the imperfect charge compensation at the counter electrode and preexisting a-domain walls, leading to asymmetric switching. It was found that the preexisting a-domains split into fine a- and c-domains constituting a $90^{\circ}$ stripe domain pattern during the $180^{\circ}$ polarization switching process, revealing that these domains also actively participated in the out-of-plane polarization switching. The real-time observations uncovered the origin of the switching asymmetry and further clarified the importance of charged domain walls and the interfaces with electrodes in the ferroelectric switching processes.

  • PDF