• 제목/요약/키워드: Two electrode system

검색결과 288건 처리시간 0.026초

발진주파수 및 전도도를 통한 오손도 자동측정 (Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency)

  • 최남호;구경완;이명섭;한상옥;정재기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

휴대형 혈액가스 분석시스템의 구현 (Implementation on the Portable Blood Gas Analyzer)

  • 강성철;정도운;배진우;손정만;심윤보;전계록
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2006년도 춘계종합학술대회
    • /
    • pp.1032-1036
    • /
    • 2006
  • In this study, we implement the potable blood gas analyzer measuring pH, $pCO_2\;and\;pO_2$ of the arterial blood. The implemented system by this study is divided into hardware and software part and also the hardware portion is parted by mechanism and electronic circuit mit. The system program is composed of operating, washing, correcting and measuring program. And to correct the system, two-point calibration method is used, one-point calibration method is also added for more accuracy, and system program is coded. For verifying the implemented system, We examine to response property of each electrode. And evaluate accuracy of the system using standard reagent and was construed as statistical.

  • PDF

Operation optimization of auxiliary electric boiler system in HTR-PM nuclear power plant

  • Du, Xingxuan;Ma, Xiaolong;Liu, Junfeng;Wu, Shifa;Wang, Pengfei
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2840-2851
    • /
    • 2022
  • Electric boilers (EBs) are the backup steam source for the auxiliary steam system of high-temperature gas-cooled reactor nuclear power plants. When the plant is in normal operations, the EB is always in hot standby status. However, the current hot standby operation strategy has problems of slow response, high power consumption, and long operation time. To solve these problems, this study focuses on the optimization of hot standby operations for the EB system. First, mathematical models of an electrode immersion EB and its accompanying deaerator were established. Then, a control simulation platform of the EB system was developed in MATLAB/Simulink implementing the established mathematical models and corresponding control systems. Finally, two optimization strategies for the EB hot standby operation were proposed, followed by dynamic simulations of the EB system transient from hot standby to normal operations. The results indicate that the proposed optimization strategies can significantly speed up the transient response of the EB system from hot standby to normal operations and reduce the power consumption in hot standby operations, improving the dynamic performance and economy of the system.

전극 구조에 관한 2차원 RF 플라즈마의 모델링 (Modeling of Two-dimensional Self-consistent RF Plasmas on Discharge Chamber Structures)

  • 소순열;임장섭;김철운
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 연구에서는 2차원적 유체 모델을 통하여 보다 실질적인 플라즈마를 이해하고자 하였으며, 기하학적인 방전전극 구조를 반영하도록 전극단에서 챔버 외벽의 거리를 변화시키면서 플라즈마의 특성을 정량적으로 비교 분석하고자 하였다. 방전 챔버의 구조로서, 전극의 반경과 방전 챔버의 높이는 일정하게 유지하면서 방전 챔버의 넓이를 변화시킴에 따라 형성되는 플라즈마의 특성을 분석하였다. 그 결과, 전극단과 챔버 외벽의 거리가 짧을수록 그 영역에서 전계가 강하게 형성되어, 외벽을 향하는 각 입자들의 움직임도 매우 활발하다는 것을 알 수 있었다. 또한, 전각단과 외벽과의 거리가 짧을수록 전극 면상에서 형성되는 입자들의 수밀도와 유속의 변화가 일정하게 형성되는 것을 알 수 있었다. 이러한 결과는 웨이퍼의 대구경화에 따른 플라즈마의 균일성을 고려할 경우에 매우 효과적일 것으로 고려되어 진다.

Synthesis of Mesoporous Carbons with Controllable N-Content and Their Supercapacitor Properties

  • Kim, Jeong-Nam;Choi, Min-Kee;Ryoo, Ryong
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권2호
    • /
    • pp.413-416
    • /
    • 2008
  • A synthesis route to ordered mesoporous carbons with controllable nitrogen content has been developed for high-performance EDLC electrodes. Nitrogen-doped ordered mesoporous carbons (denoted as NMC) were prepared by carbonizing a mixture of two different carbon sources within the mesoporous silica designated by KIT-6. Furfuryl alcohol was used as a primary carbon precursor, and melamine as a nitrogen dopant. This synthesis procedure gave cubic Ia3d mesoporous carbons containing nitrogen as much as 13%. The carbon exhibited a narrow pore size distribution centered at 3-4 nm with large pore volume (0.6-1 cm3 g-1) and high specific BET surface area (700-1000 m2 g-1). Electrochemical behaviors of the NMC samples with various N-contents were investigated by a two-electrode measurement system at aqueous solutions. At low current density, the NMC exhibited markedly increasing capacitance due to the increase in the nitrogen content. This result could be attributed to the enhanced surface affinity between carbon electrode and electrolyte ions due to the hydrophilic nitrogen functional groups. At high current density conditions, the NMC samples exhibited decreasing specific capacitance against the increase in the nitrogen content. The loss of the capacitance with the N-content may be explained by high electric resistance which causes a significant IR drop at high current densities. The present results indicate that the optimal nitrogen content is required for achieving high power and high energy density simultaneously.

쉘 구조물의 진동제어를 위한 분포형 압전 감지기/작동기의 설계 최적화 (Distributed Piezoelectric Sensor /Actuator Optimal Design for Active Vibration Control of Shell Structure)

  • 황준석;목지원;김승조
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.154-157
    • /
    • 2000
  • Distributed piezoelectric sensor and actuator system has been designed for the active vibration control of shell structure. PVDF is used for the materials of sensor/actuator. To prevent the adverse effect of spillover, distributed modal sensor/actuator system is established. Although shell structure is three-dimensional structure, the PVDF sensor/actuator system can be treated as two-dimensional Finite element programs are developed to consider curved structures having PVDF modal sensor/actuator. The nine-node Mindlin shell element with five nodal degree of freedoms is used for finite element discretization. The electrode patterns and lamination angle of PVDF sensor/actuator are optimized to design the modal sensor/actuator system Genetic algorithm is used for optimization. Sensor is designed to minimize the observation spillover, and actuator is designed to minimize the system energy of the control modes under a given initial condition. Modal sensor/actuator for the first and second modes of singly curved cantilevered shell structure are designed using mentioned methods. Discrete LQG method is used as a control law. Experimental demonstrations of the active vibration control with designed sensor/actuator system have been performed successfully.

  • PDF

접촉력 및 미끄러짐을 감지 가능한 촉각 센서의 개발 (Development of Tactile Sensor for Detecting Contact Force and Slip)

  • 최병준;강성철;최혁렬
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.364-372
    • /
    • 2006
  • In this paper, we present a finger tip tactile sensor which can detect contact normal force as well as slip. The sensor is made up of two different materials, such as polyvinylidene fluoride (PVDF) known as piezoelectric polymer, and pressure variable resistor ink. In order to detect slip on the surface of the object, two PVDF strips are arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, a tactile sensing system is developed, which includes miniaturized charge amplifier to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

ISE 기반의 임베디드 시스템을 이용한 실시간 수경재배 양액 모니터링 (Real-time Nutrient Monitoring of Hydroponic Solutions Using an Ion-selective Electrode-based Embedded System)

  • 한희조;김학진;정대현;조우재;조영열;이공인
    • 생물환경조절학회지
    • /
    • 제29권2호
    • /
    • pp.141-152
    • /
    • 2020
  • 본 연구는 양액 내 존재하는 다량 영양소의 농도를 실시간으로 측정하기 위해 이온 선택 전극 (ISE) 으로 구성된 임베디드 시스템의 개발을 보여준다. NO3, K 및 Ca 이온을 감지하기위한 PVC ISE, H2PO4를 감지하기위한 코발트 전극, 기준 전극, 샘플 용액이 담기는 챔버, 펌프 및 밸브를 사용하여 측정하는 시스템으로 구성된다. 양액 샘플양 조절과 데이터 수집을 위해서 데이터 Due 보드가 사용되었고, 각각의 샘플 측정 전에, 측정 중 발생하는 드리프트를 최소화시키기 위해 2 점 정규화 방법을 사용하였다. PVC 멤브레인을 기반으로 한 NO3 및 K 전극의 농도 예측 성능은 표준 분석기의 결과와 근접한 일치 (R2 = 0.99) 나타내며 만족스러운 결과를 나타냈다. 하지만, Ca II 이온 투과체 제조된 Ca 전극은 고농도 양액 농도에서 Ca 농도를 55 %로 낮게 측정하였다. 코발트 전극 기반 인산 측정은 반복측정 중에 발생한 코발트 전극의 불안정한 신호로 인해 표준 방법과 비교하여 45 ~ 155 mg / L의 인산 농도 범위에서 24.7 ± 9.26 %의 비교적 높은 오차를 나타냈다. 수경 P 감지의 예측 능력을 향상시키기 위해 코발트 전극의 신호 컨디셔닝에 대한 추가 연구가 필요함으로 판단된다.

ERF와 산업용 콘트롤러를 이용한 FHA의 제어특성에 관한 연구 (A Study on the Control Characteristics of FHA by Using ERF and Industrial Controller)

  • 정성철
    • 한국공작기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.95-100
    • /
    • 2005
  • Making the best use of the features of the electro-rheological(ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. In addition, the performance of the plate type ER-Valve is investigated by change the particle concentration of the ER fluid. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power control system. Using the minかnぉd pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system fir the ER Valve which occurs from industrial controller(PLC).

고빈도 경피신경전기자극의 자극강도에 따른 정상 성인여성 교감신경성 반응의 변화 (Changes in Sympathetic Nervous System Responses of Healthy Adult Women with Changes in the Stimulus Intensity of High Frequency Transcutaneous Electrical Nerve Stimulation)

  • 최유림;이정우
    • The Journal of Korean Physical Therapy
    • /
    • 제22권1호
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the change in sympathetic nervous system responses of healthy adult women with changes in stimulus intensity of high frequency transcutaneous electrical nerve stimulation. Methods: Twenty-four healthy subjects (women) received high frequency electrical stimulation of the forearm. The subjects were randomly assigned to one of two groups; a low intensity stimulation group (n=12) and a high intensity stimulation group (n=12). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was 20 minutes. Measured items included skin conductance, pulse rate, skin temperature, and respiration rate. Each was measured at 4 times. Results: Skin conductance and skin temperature showed significant group by time interactions, though there were no significant group and time effects. There were no significant differences according to time, group effect, and a group by time interaction in pulse and respiration rates. Conclusion: High frequency and high intensity electrical stimulation may be helpful for the improvement of sudomotor function through the activation of the sympathetic nervous system. Also, high frequency and low intensity electrical stimulation may be helpful for the reduction of sudomotor function via inhibition of the sympathetic nervous system.