두 대의 압축기를 적용한 에어컨의 오일분배 특성에 관한 실험적 연구 (The Experimental Study on Uniform Distribution of Oil at the Air Conditioning System using Two Compressors)

  • 김철민;황윤제;정백영
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.103-108
    • /
    • 2003
  • The common accumulator was designed for solving the maldistribution problem of oil at the air conditioning system with two compressors. The oil level inside two compressors was visualized by using a common accumulator on the various operating conditions. As a result of the visualization, oil distribution inside two compressors was achieved appropriately according to the capacity of each compressor. Uniform distribution of oil was also accomplished at on and off operation condition.

Series Design of Compressors for Two-Stage Centrifugal Chiller

  • Jinhee Jeong;Lee, Hyeongkoo
    • Journal of Mechanical Science and Technology
    • /
    • 제17권2호
    • /
    • pp.288-295
    • /
    • 2003
  • A preliminary series design of compressors for a two-stage centrifugal chiller is suggested. Six groups of hydrodynamically similar compressors, ranging from 233RT to 1,200RT, are introduced. Flow rates, impeller diameters, and wheel speeds for each group are determined from hydrodynamic similarity to share impellers of adjacent groups. It is expected that these compressors can have the same performance and efficiency from the smallest model to the largest one.

원심형 임펠러에 대한 이구역 모델링 (Two-Zone Modeling for Centrifugal Impellers)

  • 오형우;정명균;김재원
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1129-1138
    • /
    • 1999
  • This paper presents a systematic two-zone modeling for reliable performance prediction of centrifugal compressors. In order to improve the predictive capability, a modified jet slip factor is developed and new corrections for the wake flow deviation and mass fraction are suggested based on the comprehensive experimental data of the three Eckardt impellers. The proposed two-zone modeling is tested against nine sets of measured data of centrifugal compressors. The results are also compared with those obtained by the mean streamline analysis. It was found that the predictions by the present two-zone modeling agree fairly well with experimental data for a variety of centrifugal compressors over the wide operating conditions.

1.2MW급 산업용 가스터빈 원심압축기 개발(1)- 공력설계해석 - (Development of Centrifugal Compressors in an 1.2MW Industrial Gas Turbine(I)-Aerodynamic Design and Analysis-)

  • 조규식;이헌석;손정락
    • 대한기계학회논문집B
    • /
    • 제20권8호
    • /
    • pp.2707-2720
    • /
    • 1996
  • The aerodynamic design of the two-stages of centrifugal compressors in an 1.2MW industrial gas turbine is completed with the application of numerical analyses. The final shape of an intake, the axial guide vanes and a return channel is determined using several interactions between design and two-dimensional turbulent flow analysis, focused on the minimum loss of internal flows. The one-dimensional turbulent flow analysis, focused on the minimum loss of internal flows. The one-dimensional design and prediction of aerodynamic performances for the compressors are performed by two different methods; one is a method with conventional loss models, and the other a method with the two-zone model. The combination methods of the Betzier curves generate three-dimensional geometric shapes of impeller blades which are to be checked with a careful change of aerodynamic blade loadings. The impeller design is finally completed by the applications of three-dimensional compressible turbulent flow solvers, and the effect of minor change of design of the second-stage channel diffuser is also studied. All the aerodynamic design results are soon to the verified by component performance tests of prototype centrifugal compressors.

저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구 (The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors)

  • 황윤제;조은준;정백영;이감규
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.201-208
    • /
    • 2005
  • This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.

Performance Comparison of Various Types of $CO_2$ Compressors for Heat Pump Water Heater Application

  • Kim, Hyun-Jin;Kim, Woo-Young;Ahn, Jong-Min
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권4호
    • /
    • pp.115-122
    • /
    • 2009
  • Numerical simulations for scroll, two-stage twin rotary, and two-cylinder reciprocating compressors have been carried out to understand the effectiveness of each type compressor for heat pump water heater application using $CO_2$ as refrigerant. For suction pressure of 3.5 MPa and discharge pressure of 9 MPa, clearance volume ratio of the reciprocating compressor needs to be about 5% or less to have the volumetric efficiency comparable to that of the scroll compressor with tip clearance of $5\;{\mu}m$. Volumetric efficiency of the scroll compressor is quite sensitive to tip clearance. Adiabatic efficiency of the twin rotary compressor was calculated to be the lowest among the three types, and the most severe drawback of the $CO_2$ scroll compressor was a significant increase in the mechanical loss at the thrust surface supporting the orbiting scroll member. While the scroll compressor showed very smooth torque load variation, peak-to-peak torque variations of the twin rotary and two-cylinder reciprocating compressors were about 50% and 250%, respectively.

소형 원심 압축기의 성능 향상을 위한 베인 없는 디퓨저와 볼류트 케이싱의 설계에 관한 연구 (A study on the vaneless diffuser and volute casing design for the improvement of small centrifugal compressors)

  • 조재필;백승윤;김성돈;안규복
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.3722-3730
    • /
    • 2015
  • 하수 처리용으로 사용되는 소형 원심 압축기의 베인 없는 디퓨져와 볼류트 케이싱의 성능 개선을 수행하였다. 기존의 두 모델은 임펠러가 동일하나, 베인 없는 디퓨져의 폭과 길이 및 볼류트 케이싱의 형상은 서로 다르다. 기존 모델에 대한 실험과 유동해석 결과를 바탕으로 베인 없는 디퓨져와 볼류트 케이싱의 설계를 변경하였다. 세 모델에 대한 연구 결과로부터, 볼류트 케이싱의 단면적 및 입구 반경 길이는 볼류트 혀와 베인 없는 디퓨져 및 임펠러와의 상호작용 강도에 영향을 주었고, 시스템 손실량에 변화를 나타내었다. 베인 없는 디퓨져 폭이 감소하면 임펠러의 효율은 증가했지만 디퓨져에서의 손실도 증가하였다. 결과적으로 개선된 모델의 효율이 설계 점에서 기존 대비 약 2.88%p 향상된 것이 유동해석 결과로 확인되었다.

Defect classification of refrigerant compressor using variance estimation of the transfer function between pressure pulsation and shell acceleration

  • Kim, Yeon-Woo;Jeong, Weui-Bong
    • Smart Structures and Systems
    • /
    • 제25권2호
    • /
    • pp.255-264
    • /
    • 2020
  • This paper deals with a defect classification technique that considers the structural characteristics of a refrigerant compressor. First, the pressure pulsation of the refrigerant flowing in the suction pipe of a normal compressor was measured at the same time as the acceleration of the shell surface, and then the transfer function between the two signals was estimated. Next, the frequency-weighted acceleration signals of the defect classification target compressors were generated using the estimated transfer function. The estimation of the variance of the transfer function is presented to formulate the frequency-weighted acceleration signals. The estimated frequency-weighted accelerations were applied to defect classification using frequency-domain features. Experiments were performed using commercial compressors to verify the technique. The results confirmed that it is possible to perform an effective defect classification of the refrigerant compressor by the shell surface acceleration of the compressor. The proposed method could make it possible to improve the total inspection performance for compressors in a mass-production line.

싱글 스크류 압축기의 스크류 로터의 설계 및 가공 (Design and Machining of a Screw Rotor of a Single-Screw Compressor)

  • 김두형;경진호;김왕환
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.452-457
    • /
    • 2016
  • Single screw compressors are widely used in the fields of air/gas compression, refrigeration, and chemical fluid transportation systems. A single-screw compressor is composed of a screw rotor and two gate rotors located at both sides. This simple construction enables low rotational speed of the rotor, efficient compression with low noise, low vibration, and long bearing life. Despite these merits, the design method of single-screw compressors is not well known. To accelerate the industrial application of single-screw compressors, a design method using coordinate transformation is presented in this paper, and a tool trajectory is established for machining. Finally, the screw rotor, which is machined using the proposed method, is presented.

진동평면모델을 이용한 스크롤 압축기 균형추 설계 (Balancer design for scroll compressors using vibration plane model)

  • 서정환;이동수;김승엽;조남규;이형국
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.527-532
    • /
    • 2004
  • An effective balancing method for mil compressors is developed based on vibration plane model. By assuming the design range of balancer size is not large and considering only the radial axial direction rigid vibration of the mil compressors, we can find the vibration plane (V-plane) describing the vibration level of the scroll compressor depending upon balancer design specifications. By in the intersection of two minimum lines (areas) obtained from the couple of V-Planes we can find the design lesion to minimize vibration level of the compressor. The full design process is described by using an illustrative example with upper and lower balancer weights. Further more sensitivity analysis of parameters important for designation of size and positioning of the balancer is analyzed.

  • PDF