• Title/Summary/Keyword: Two Reference Beam

Search Result 153, Processing Time 0.061 seconds

In-vitro assessment of the accuracy and reliability of mandibular dental model superimposition based on voxel-based cone-beam computed tomography registration

  • Han, Gaofeng;Li, Jing;Wang, Shuo;Liu, Yan;Wang, Xuedong;Zhou, Yanheng
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.97-105
    • /
    • 2019
  • Objective: This study was performed to evaluate the accuracy and reliability of a newly designed method to achieve mandibular dental model superimposition, using voxel-based cone-beam computed tomography (CBCT) registration. Methods: Fourteen dry cadaveric mandibles and six teeth extracted from patients with severe periodontitis were used to establish 14 orthodontic tooth-movement models. The protocol consisted of two steps: in the first step, voxel-based CBCT mandible superimposition was performed; the reference comprised the external portion of the symphysis, extending to the first molar. The laser-scanned dental model image was then integrated with the CBCT image to achieve mandibular dental model superimposition. The entire process required approximately 10 minutes. Six landmarks were assigned to the teeth to measure tooth displacement, using tooth displacement on the superimposed laser-scanned mandibles as the reference standard. Accuracy was evaluated by comparing differences in tooth displacement based on the method and the reference standard. Two observers performed superimposition to evaluate reliability. Results: For three-dimensional tooth displacements, the differences between the method and the reference standard were not significant in the molar, premolar, or incisor groups (p > 0.05). The intraclass correlation coefficients for the inter- and intra-observer reliabilities of all measurements were > 0.92. Conclusions: Our method of mandibular dental model superimposition based on voxel registration is accurate, reliable, and can be performed within a reasonable period of time in vitro, demonstrating a potential for use in orthodontic patients.

A Development of Diaphragm Sensor for Detecting Partial Discharge (부분방전 측정을 위한 Diaphragm 센서 개발)

  • Kang, W.J.;Park, Y.I.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1528-1530
    • /
    • 1998
  • In this work, a possible new PD detection technique, based on the Michelson Interferometer, has been proposed. Laser beam transmitted by optical fiber is spliced into two-laser beam by 50/50 coupler, one is reflected on diaphragm, which is vibrated by ultrasonic sound, and then modulated. The other one is reference beam. They are collected into 50/50 coupler making interferenced beam which could be detected by photo detector.

  • PDF

Dynamic Characteristic Analysis of a Flexible Beam Actuated by Moving Coil and DC Motor (가동 코일 및 DC Motor로 작동되는 유연한 빔의 운동 특성 해석)

  • Yu, Hwajoon;Jeong, Wontaick;Nam, Yoonsu
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.15-23
    • /
    • 1999
  • Active damping system is generally used for the vibration suppression and precise motion control for the flexible structure. This application can be easily found on the space structure and driving mechanism of optical storage devices. Although a control system using the flexible structure has many advantages over using rigid mechanism in driving energy saving, system weights, and etc., more complex and precise control strategies are required. A position control system using flexible structure and the concept of active damper is designed and manufactured, which is driven by slide DC motor and moving coil motor located at the tip of the flexible beam. Dynamic characteristics of this system are investigated by analytic and experimental ways. By the comparison of those two results, a nominal reference model for this system is proposed.

  • PDF

A Yew Technique for Infrared Spectroscopy using Polyethylene Film Cell (Polyethylene Film을 利用한 赤外線分光分析用 Cell)

  • Sung, Chwa-Kyung;Noh, Ick-Sam
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.1
    • /
    • pp.58-64
    • /
    • 1963
  • Authors propose a new technique using polyethylene film instead of sodium chloride window as a cell material. Nujol mulls, liquids and aqueous solutions are sandwitched between two pieces of polyethylene film which are held between cardboards. Ordinary lead or stainless steel spacers could be used if exact cell thickness is desired. A more elaborate cell can be assembled by injecting samples between two pieces of polyethylene film which are placed between sodium chloride windows of ordinary demountable liquid cell. The absorption bands due to polyethylene and Nujol are compensated by placing the polyethylene film of suitable thickness in the reference beam. The absorption bands due to solvents such as water can also be compensated by the polyethylene film cell sandwitched solvent of suitable thickness in the reference beam. This method would be a simple new technique. Especially this technique may offer a new helpful way for the investigation of the state of substances in aqueous system. Using this technique, authors have observed the appearance of an absorption bands at 3.2 micron, in the spectrum of phenol in aqueous solution, that is absent in the spectrum of phenol in benzene solution. The same absorption band also has been observed in the spectra of aqueous formaldehyde solution and aqueous polyvinyl alcohol solution, where the absorption bands due to polyethylene and water are compensated. Although it may be regarded that this absorption band is related to the intermolecular interaction between water and the solute having OH group, that is hydrogen bonding. The exact assignment of this absorption band is out of this work.

  • PDF

Three-dimensional relative-distance measurement by use of the phase-shifting digital holography (위상천이 디지털 홀로그래피를 이용한 3차원 상대 거리 측정)

  • Kim, Hyun;Lee, Yeon-H.
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.2
    • /
    • pp.200-207
    • /
    • 2003
  • In this paper we present a new method of measuring the relative distance of two point objects in three-dimensional space by using phase-shifting digital holography. In our system the reference beam of a spherical wave is used instead of a plane wave. The system is computer simulated and built on an optical table for experiments. It is shown from computer simulations and experiments that the relative distance can be measured without the exact information on the reference beam used in the hologram record. It is shown from experiments that the relative distance between two point objects separated by 0.5 cm in the distance of about 300 cm from the CCD can be measured with an error less than 10%.

Development of Degenerated Beam Elements Using Higher-Order Displacement Profile (고차(高次) 변위(變位)를 고려(考慮)한 요소(要素)의 해석(解析))

  • Shin, Young Shik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.75-86
    • /
    • 1982
  • The degeneration of two classes of thick beam elements has been conducted, one (DB6) based on the conventional Timoshenko beam assumptions whereas the other (DB7) based on the assumed cubic axial displacement profile. While an adjustable shear correction factor is required for the DB 6 element to compensate for the unrealistic distribution of shear strain across the thickness, the DB 7 element assumes the more realistic quadratic profile of shear strain at the outset. With the plane-stress continuum solution as reference, solutions obtained by these two element models are compared with the analytical Timoshenko solution, the analytical thin beam solution and several available solutions of other existing beam elements. The result indicates that the performance of the higher order beam element DB 7 is consistently superior to any others. This is true for the whole range of aspect ratios of beam, in both static and free vibration analyses.

  • PDF

A modified replacement beam for analyzing building structures with damping systems

  • Faridani, Hadi Moghadasi;Capsoni, Antonio
    • Structural Engineering and Mechanics
    • /
    • v.58 no.5
    • /
    • pp.905-929
    • /
    • 2016
  • This paper assesses efficiency of the continuum method as the idealized system of building structures. A modified Coupled Two-Beam (CTB) model equipped with classical and non-classical damping has been proposed and solved analytically. In this system, complementary (non-classical) damping models composed of bending and shear mechanisms have been defined. A spatial shear damping model which is non-homogeneously distributed has been adopted in the CTB formulation and used to equivalently model passive dampers, viscous and viscoelastic devices, embedded in building systems. The application of continuum-based models for the dynamic analysis of shear wall systems has been further discussed. A reference example has been numerically analyzed to evaluate the efficiency of the presented CTB, and the optimization problems of the shear damping have been finally ascertained using local and global performance indices. The results reveal the superior performance of non-classical damping models against the classical damping. They show that the critical position of the first modal rotation in the CTB is reliable as the optimum placement of the shear damping. The results also prove the good efficiency of such a continuum model, in addition to its simplicity, for the fast estimation of dynamic responses and damping optimization issues in building systems.

Optical Decryption System of Binary Image Using Two-Wave Mixing in Photorefractive Crystal (광굴절 매질에서 2광파 혼합을 이용한 이진 영상 복호화 시스템)

  • 최상규;신창목;서동환;김철수;김수중
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.83-86
    • /
    • 2002
  • We suggest binary image decryption system using two-wavc mixing in Photorefractive crystal. Compared with a conventional method, this method can make optical alignment easily, and brighten the encrypted image even if a small input signal, by index grating of photorefractive crystal. Also it can reconstruct the encrypted image by only reference beam in real time.

  • PDF

Optical Decryption System of Binary Image Using Two-Wave Mixing in Photorefractive Crystal (광굴절 매질에서 2광파 혼합을 이용한 이진 영상 복호화 시스템)

  • 최상규;신창목;서동환;김철수;김수중
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.207-210
    • /
    • 2002
  • We suggest binary image decryption system using two-wave mixing in photorefractive crystal. Compared with a conventional method, this method can make optical alignment easily, and brighten the encrypted image even if a small input signal, by index grating of photorefractive crystal. Also it can reconstruct the encrypted image by only reference beam in real time.

  • PDF

Use of Reference Ear Plug to improve accuracy of lateral cephalograms generated from cone-beam computed tomography scans

  • Hwang, Hyeon-Shik;Lee, Kyung-Min;Uhm, Gi-Soo;Cho, Jin-Hyoung;McNamara, James A. Jr.
    • The korean journal of orthodontics
    • /
    • v.43 no.2
    • /
    • pp.54-61
    • /
    • 2013
  • Objective: The purpose of this study was to evaluate the effectiveness of the use of Reference Ear Plug (REP) during cone-beam computed tomography (CBCT) scan for the generation of lateral cephalograms from CBCT scan data. Methods: Two CBCT scans were obtained from 33 adults. One CBCT scan was acquired using conventional methods, and the other scan was acquired with the use of REP. Virtual lateral cephalograms created from each CBCT image were traced and compared with tracings of the real cephalograms obtained from the same subject. Results: CBCT scan with REP resulted in a smaller discrepancy between real and virtual cephalograms. In comparing the real and virtual cephalograms, no measurements significantly differed from real cephalogram values in case of CBCT scan with REP, whereas many measurements significantly differed in the case of CBCT scan without REP. Conclusion: Measurements from CBCT-generated cephalograms are more similar to those from real cephalograms when REP are used during CBCT scan. Thus, the use of REP is suggested during CBCT scan to generate accurate virtual cephalograms from CBCT scan data.