• 제목/요약/키워드: Two Difference Voltage

검색결과 278건 처리시간 0.05초

수정에 의한 Mouse egg의 세포막전류 변화 (Changes in the inward current and membrane conductance after fertilization in the mouse eggs)

  • 홍성근;박춘옥;한재희;김익현;하대식;권종국
    • 대한수의학회지
    • /
    • 제32권2호
    • /
    • pp.157-164
    • /
    • 1992
  • Changes in the both inward current and conductance of membrane by the fertilization were observed using the one microelectrode voltage clamp(or switch clamp) technique. Unfertilized eggs and both 1- and 2-cell stage eggs after fertilization were donated from the superovulated mouse (ICR, more than 6 weeks old) treated with PMSG(pregnant mare serum gonadotropin, Sigma) and HCG(human chorionic gonadotropin, Sigma) and naturally mated ones, respectively in this experiment. Membrane potential was held at -90mV and the voltage step was applied from -80mV to 50mV with interval of 10mV or 20mV for 300ms. since both of amplitudes and time courses in the membrane currents were various according to the states of cells and clamping condition, results were presented by their $averages{\pm}SEM$(standard mean error)and ratios or percentages. Inward currents began to appear in response to the step depolarization from -60mV and reached its maximum at -50mV. However, since the potential was not clamped evenly during the voltage step, current-voltage(I-V) relationship might be positively shifted 10 or 20mV. From the steady-state currents plotted in the I-V curve, outward rectification was markedly observed. Peak inward currents$(i_{in})$ at -50mV were $-0.62{\pm}0.23nA$(n=4),$-0.52{\pm}0.25nA$(n=5) and $-0.37{\pm}0.25nA$(n=6), in the 1-cell stage, 2-cell stage fertilized eggs and in the unfertilized eggs, respectively. Pure inward current (difference between steady-state and peak, $i_{in. pure}$) were $-1.01{\pm}0.23nA$, $-0.69{\pm}0.43nA$ and $-0.68{\pm}0.29nA$, respectively in the 1-cell stage fertilized eggs, unfertilized eggs and 2-cell stage fertilized eggs. These results suggested that the outward current in fertilized eggs of 2-cell stage was more increased than those in the unfertilized eggs. Pure inward currents in the all stages of eggs showed a similar fashion in the I-V relationship from -50mV to 50mV and reversal potential at 50mV. Time constant of inactivation$({\tau})$ in the inward current was decreased as the membrane potential was depolarized in the unfertilized and 2-cell stage eggs but in the 1-cell stage eggs t was not likely to be affected significantly. Slope conductances were 14.2nS, 8.9n5 and 7.7nS in the 1-cell, 2-cell stage fertilized eggs and the unfertilized eggs, respectively. Membranes between two cells within a zona pellucida seem to be electrical-connected in the 2-cell stage eggs from the observation made in the analysis for the electronic spread and decay to the current stimuli. Both of inward current and membrane conductance were increased after fertilization in the mouse eggs. Inward current seems to be carried by the same ion or through the same channels up to the 2-cell stage and ion that carried inward current was thought to play important function after fertilization in the mouse eggs.

  • PDF

보호 회로를 포함한 무선 전력 전송용 ISM 13.56 MHz 20 W Class-E 앰프 설계 (Design of 20 W Class-E Amplifier Including Protection for Wireless Power Transmission at ISM 13.56 MHz)

  • 남민영;김영식
    • 한국전자파학회논문지
    • /
    • 제24권6호
    • /
    • pp.613-622
    • /
    • 2013
  • 본 논문에서는 ISM 13.56 MHz 대역 무선 전력 전송을 위한 인덕티브 클램핑 class-E 전력증폭기를 설계 및 실험하여 특성을 분석하였다. 구현된 전력증폭기는 수신 안테나가 회전체에 붙는 경우와 같이 송수신 안테나 간의 정합 상태가 변화하는 시스템에서 부정합 상태에서 전력증폭기에 공급되는 전류를 줄여 트랜지스터를 손상시키지 않고 안정적으로 동작하도록 하는 인덕티브 클램핑 방식으로 설계되었으며, 정합 회로를 이용하여 기존의 class-E 전력증폭기보다 고조파 성분에 대한 Filtering 특성을 개선하였다. 구현된 전력증폭기의 입력 주파수는 13.56 MHz, 입력 전력 25 dBm, 동작 전압 DC 28 V에서 측정한 결과, 출력 전력은 43 dBm, 기본 주파수 성분과 2차 고조파 신호 간의 출력 전력 차이 55 dBc 이상, 소모 전류 830 mA으로 전력부가 효율(power added efficiency)은 85 %로 높게 측정됐다. 마지막으로, 수신 안테나를 회전체에 부착하고 구현된 전력증폭기로 송수신 안테나로 전력을 송출하는 실험을 진행하였으며, 송신 안테나의 부정합 상태에는 소모 전류가 420 mA까지 줄어들어 트랜지스터가 손상되지 않는 것을 확인하였다.

토모테라피를 이용한 간암환자의 정위적 방사선치료시 복부압박장치의 유용성 평가 (Usefulness of Abdominal Compressor Using Stereotactic Body Radiotherapy with Hepatocellular Carcinoma Patients)

  • 우중열;김주호;김준원;백종걸;박광순;이종민;손동민;이상규;전병철;조정희
    • 대한방사선치료학회지
    • /
    • 제24권2호
    • /
    • pp.157-165
    • /
    • 2012
  • 목 적: 간에 발생한 절제 불가능한 원발성 및 전이성 종양에서 토모테라피를 이용한 정위적 방사선치료를 시행하기 위해 사용된 복부압박장치의 유용성을 평가하고자 하였다. 대상 및 방법: 2011년 11월부터 2012년 3월까지 토모테라피(Hi-Art Tomotherapy, USA)를 시행받기 위해 본원에 내원한 간암환자 중 복부압박장치(diaphragm control, elekta, sweden)를 사용하였을 때 움직임이 1 cm 이상 줄어든 환자를 대상으로 하였다. 4D CT (somatom sensation, siemens, germany)를 통해 치료계획영상과 4차원 단층촬영영상을 촬영하고, 육안적으로 보이는 종양과 종양의 움직임을 고려하여 육안적 종양체적(gross tumor volume, GTV)으로 설정하였고, GTV 주변으로 균일하게 5~7 mm의 여유를 주어 치료계획용 종양체적(planning target volume, PTV)으로 설정하였다. 손상위험장기(organs at risk) 중 십이지장, 위, 대장의 거리가 종양으로부터 최소 1 cm 이상인 환자들을 1군($d{\geq}1$)으로, 1 cm 미만인 환자들을 2군(d<1)으로 분류하고 각각 4~5회의 정위적 방사선치료와 20회의 방사선치료를 계획하였다. Mega-voltage computed tomograpy (MVCT)와 kilo-voltage computed tomograpy (KVCT)를 일차적으로 골격구조셋팅(bone-technique)으로 융합(fusion)한 뒤, 이차적으로 간을 보며 영상을 재조정 하였다. 치료 후 얻은 MVCT 영상을 영상변형이 가능한 Mim_vista (Mimsoftware, ver. 5.4 USA)로 보내고, 간을 비교하여 다시 묘사(delineate)하고, 손상위험장기 중 십이지장, 위, 소장, 대장을 합쳐서 대장장기(bowel_organ)로 정의하여 다시 묘사하였다. 보정방사선 치료계획시스템을 통하여 보정영상의 치료계획 선량과 보정된 선량의 차이를 평가하였다. 첫 번째, 치료 시작일부터 각각 1군($d{\geq}1$)은 4회, 2군(d<1)은 10회까지의 MVCT와 KVCT간의 영상 융합을 통한 셋업오차를 분석하였다. 두 번째, 보정영상에서 종양 즉, GTV, PTV의 치료계획선량과 보정선량의 3%의 선량차이를 나타내는 체적($V_{diff3%}$)과 5%의 선량차이를 나타내는 체적($V_{diff3%}$)을 비교하였고, 손상위험장기 중 대장장기의 최대선량의 차이율을 비교하였다. 결 과: MVCT를 통해 분석한 평균 셋업오차는 $-0.66{\pm}1.53$ mm (좌-우), $0.39{\pm}4.17$ mm (상-하), $0.71{\pm}1.74$ mm (전-후), $-0.18{\pm}0.30$ degrees (roll)였다. 1군($d{\geq}1$)과 2군(d<1)의 셋업오차는 유사하였다. 1군($d{\geq}1$)에서 보정방사선 치료계획을 통한 $V_{diff3%}$ 중 GTV는 $0.78{\pm}0.05%$, PTV는 $9.97{\pm}3.62%$, $V_{diff5%}$ 중 GTV는 0.0%, PTV는 $2.9{\pm}0.95%$, 대장장기의 최대선량의 차이율은 $-6.85{\pm}1.11%$였다. 2군(d<1)에서 $V_{diff3%}$ 중 GTV는 $1.62{\pm}0.55%$, PTV는 $8.61{\pm}2.01%$, $V_{diff5%}$ 중 GTV는 0.0%, PTV는 $5.33{\pm}2.32%$, 대장장기의 최대선량의 차이율은 $28.33{\pm}24.41%$였다. 결 론: 복부압박장치를 통한 간암의 방사선치료시 MVCT를 통한 환자 셋업오차는 평균 ${\pm}5$ mm 이하였고, 복부 압박장치를 사용하고 투시영상을 통해 확인한 횡경막의 움직임이 최소 5 mm 이상이라는 것을 감안하면, 환자 셋업오차는 그 안에 있음을 알 수 있었다. 1군($d{\geq}1$)과 2군(d<1)에서 GTV, PTV의 선량차이율은 오차범위 안에 있었고, 1군($d{\geq}1$)과 2군(d<1)의 대장장기 최대선량의 차이율은 최대 35% 이상의 차이를 보였고, 1군($d{\geq}1$)이 2군(d<1)보다 오차범위가 작았다. 따라서 간내 종양과 손상위험장기의 거리가 최소 1 cm 이상 유지된다면 정위적 방사선치료를 진행함에 복부압박장치가 도움이 될 수 있을 것으로 사료된다.

  • PDF

InAs/GaSb 응력초격자를 이용한 적외선검출소자의 제작 및 특성 연구 (Fabrication and Device Characteristics of Infrared Photodetector Based on InAs/GaSb Strained-Layer Superlattice)

  • 김준오;신현욱;최정우;이상준;김창수;노삼규
    • 한국진공학회지
    • /
    • 제18권2호
    • /
    • pp.108-115
    • /
    • 2009
  • 150 주기의 InAs/GaSb (8/8-ML) 제2형 응력초격자 (SLS)를 활성층에 탑재한 초격자 적외선검출소자 (SLIP) 구조를 MBE 방법으로 성장하고, 직경 $200{\mu}m$의 개구면을 가지는 SLIP 개별소자를 시험 제작하였다 고분해능 투과전자현미경 (TEM) 이미지의 휘도분포와 X선회절 (XRD) 곡선의 위성피크의 분석 결과는 SLS 활성층은 균일한 층두께와 주기적 응력변형을 유지하는 급격한 계면의 초격자임을 입증하였다. 흑체복사 적외선 광원을 이용하여 측정한 입사파장 및 인가전압에 따른 반응도 (R)와 검출률 ($D^*$)로부터, 차단파장은 ${\sim}5{\mu}m$이고 최대 R과 $D^*$ ($\lambda=3.25{\mu}m$)는 각각 ${\sim}10^3mA/W$ (-0.6 V/13 K)와 ${\sim}10^9cm.Hz^{1/2}/W$ (0 V/13 K)임을 보였다. 반응도의 온도의존성으로부터 분석한 활성화에너지 275 meV는 광반응 과정에 개입되어 있는 가전대 및 전도대 부준위 사이의 에너지 간격 (HH1-C)과 잘 일치하였다.

탄성체 재질 변화에 따른 16각형 초음파모터의 토크 특성 연구 (A Study on the Torque Characteristics Depending on the Elastic Body Materials of a Hexadecagon Shaped Ultrasonic Motor)

  • 천성규;정성수;이병하;하용우;김명호;박태곤
    • 한국전기전자재료학회논문지
    • /
    • 제27권5호
    • /
    • pp.286-291
    • /
    • 2014
  • In this study, novel ultrasonic rotary motor of hexadecagon shape stator was proposed. Stator of the hexadecagon ultrasonic motor was composed of an elastic ring and ceramics. The elastic ring had sixteen sides and sixteen angular points. Eight ceramics were attached on the outer surface of the eight sides of the ring. When rotor of cylindrical shaft was inserted inside of the ring stator, central lines of the sixteen sides of the stator hold the shaft by the slight pressures(frictions). This slight pressure was a preload of the motor and it could be controlled by radius and thickness of the ring. When two sinusoidal voltages which have 90 degree phase difference were applied to each four ceramics, elliptical displacements of inner surface of the ring were obtained. These elliptical displacements of the inner surface rotated the shaft rotor through the frictions. The proposed hexadecagon ultrasonic motor was designed and analyzed by using the finite element method (FEM), depending on materials of the elastic ring. Based on the FEM results, one model of motor which showed maximum displacement at contact points was chosen and fabricated. And characteristics of the motor were compared with simulated results. When the motor was fabricated with these results, EL20ET0.5CT0.5CW2 model showed 115[rpm] speed about input voltage of 60[Vrms] at 65.6[kHz]. And the maximum torque of 6[gfcm] was obtained. From these results, the hexadecagon shaped ultrasonic motor can be used to actuator for optical device which needs detailed position control. Also it can be used to medical and portable device by reducing size and weight.

0.357 ps의 해상도와 200 ps의 입력 범위를 가진 2단계 시간-디지털 변환기의 설계 (A Design of 0.357 ps Resolution and 200 ps Input Range 2-step Time-to-Digital Converter)

  • 박안수;박준성;부영건;허정;이강윤
    • 대한전자공학회논문지SD
    • /
    • 제47권5호
    • /
    • pp.87-93
    • /
    • 2010
  • 본 논문에서는 디지털 위상동기루프에서 사용하는 고해상도와 넓은 입력 범위를 가지는 2 단계 시간-디지털 변환기(TDC)구조를 제안한다. 디지털 위상동기루프에서 디지털 오실레이터의 출력 주파수와 기준 주파수와의 위상 차이를 비교하는데 사용하는 TDC는 고해상도로 구현되어야 위상고정루프의 잡음 특성을 좋게 한다. 기존의 TDC의 구조는 인버터로 구성된 지연 라인으로 이루어져 있어 그 해상도는 지연 라인을 구성하는 인버터의 지연 시간에 의해 결정되며, 이는 트랜지스터의 크기에 의해 결정된다. 따라서 특정 공정상에서 TDC의 해상도는 어느 값 이상으로 높일 수 없는 문제점이 있다. 본 논문에서는 인버터보다 작은 값의 지연 시간을 구현하기 위해 위상-인터폴레이션 기법을 사용하였으며, 시간 증폭기를 사용하여 작은 지연 시간을 큰 값으로 증폭하여 다시 TDC에 입력하는 2 단계로 구성하여 고해상도의 TDC를 설계하였다. 시간 증폭기의 이득에 영향을 주는 두 입력의 시간 차이를 작은 값으로 구현하기 위해 지연 시간이 다른 두 인버터의 차이를 이용하여 매우 작은 값의 시간 차이를 구현하여 시간증폭기의 성능을 높였다. 제안하는 TDC는 $0.13{\mu}m$ CMOS 공정으로 설계 되었으며 전체 면적은 $800{\mu}m{\times}850{\mu}m$이다. 1.2 V의 공급전압에서 12 mA의 전류를 사용하며 0.357 ps의 해상도와 200 ps의 입력 범위를 가진다.

재구성가능 연산증폭기를 사용한 저전력 4차 델타-시그마 변조기 설계 (Design of Low Power 4th order ΣΔ Modulator with Single Reconfigurable Amplifier)

  • 성재현;이동현;윤광섭
    • 전자공학회논문지
    • /
    • 제54권5호
    • /
    • pp.24-32
    • /
    • 2017
  • 본 논문에서는 생체 신호 처리를 위한 12비트 이상의 고 해상도를 갖는 저 전력 CMOS 4차 델타-시그마 변조기를 설계하였다. 제안하는 4차 델타-시그마 변조기는 시간 분할 기법을 이용하여 회로를 시간에 따라 재구성해 4개의 연산증폭기가 필요한 회로를 1개의 연산증폭기만으로 구동 시켰다. 이를 통하여 일반적인 구조보다 전력소모를 75% 감소시킬 수 있다. 또한 kT/C 잡음과 칩 면적을 고려하여 변조기의 입력단과 출력 단의 커패시터들을 안정적으로 구동하기 위하여 적분기내 가변되는 증폭기를 설계하였다. 첫 번째와 두 번째 클럭 위상에서는 2단 연산 증폭기가 동작하고, 세 번째와 네 번째 위상에서는 1단 연산 증폭기가 동작한다. 이로 인하여 두 가지 위상 조건에서 연산증폭기의 위상여유가 60~90도 이내에 존재하게 하므로서 변조기의 안정성을 크게 향상시켰다. 제안한 변조기는 $0.18{\mu}m$ CMOS N-well 1 poly 6 metal 공정을 이용하여 제작되었으며, 1.8V의 공급전압에서 $354{\mu}W$의 전력소모가 측정되었다. 256kHz의 동작주파수, 128배의 오버샘플링 비율 조건에서 250Hz의 입력 신호를 인가하였을 때, 최대 SNDR은 72.8dB, ENOB은 11.8 비트로 측정되었다. 또한 종합 성능 평가지수인 FOM(Walden)은 49.6pJ/step, FOM(Schreier)는 154.5dB로 측정되었다.

방적성 Plasma 처리 필름으로 피복된 플라스틱온실의 풋고추 생육 (Growth of Green Pepper(Capsicum annuum L.) in a Plastic Greenhouse Covered with Anti-dropping Plasma Film)

  • 전희;김경제;김진영;김현환;이시영
    • 생물환경조절학회지
    • /
    • 제9권3호
    • /
    • pp.156-160
    • /
    • 2000
  • 플라즈마 필름은 플라스틱 필름 표면의 유적성을 향상시키기 위하여 고전압처리 되었다. 플라즈마 필름과 계면활성제 필름(대조구)를 각각 직경 25mm 두께 1.5mm 골조 파이프 하우스에 피복하였다. 또한 40일 플러그 육묘된 풋고추를 110cmx25cm 간격으로 정식하였다. 피복시 수온을 7$0^{\circ}C$로 처리된 수적발생 장치에서 나온 수증기가 필름 표면에서 응결되어 흘러내려 비이커에 모인 양을 150분 후에 측정한 결과, 플라즈마 필름에서 2.56mL.100$cm^{-2}$ , 계면활성제 필름에서 0.94mL.100$cm^{-2}$ 이 나왔다. 피복 60일 후 오전 8시 20분에 시설내 필름 표면에 부착된 수적량은 플라즈마 필름에서 0.34mL.100$cm^{-2}$ , 계면활성제필름에서 0.32mL.10$cm^{-2}$ 이었다. 광 투과율은 플라즈마 필름 피복시설이 계면활성제 피복시설 보다 2.0% 높았다. 그리고 시설내 기온은 플라즈마 필름 피복시설이 계면활성제 피복시설 보다 0.5$^{\circ}C$ 높았다. 그러나 상대습도는 차이가 없었다. 풋고추 초장, 엽면적, 건물중 및 초기수량 또한 처리간에 차이가 없었다.

  • PDF

Reliable and High Spatial Resolution Method to Identify the Number of MoS2 Layers Using a Scanning Electron Microscopy

  • Sharbidre, Rakesh Sadanand;Park, Se Min;Lee, Chang Jun;Park, Byong Chon;Hong, Seong-Gu;Bramhe, Sachin;Yun, Gyeong Yeol;Ryu, Jae-Kyung;Kim, Taik Nam
    • 한국재료학회지
    • /
    • 제27권12호
    • /
    • pp.705-709
    • /
    • 2017
  • The electronic and optical characteristics of molybdenum disulphide ($MoS_2$) film significantly vary with its thickness, and thus a rapid and accurate estimation of the number of $MoS_2$ layers is critical in practical applications as well as in basic researches. Various existing methods are currently available for the thickness measurement, but each has drawbacks. Transmission electron microscopy allows actual counting of the $MoS_2$ layers, but is very complicated and requires destructive processing of the sample to the point where it will no longer be useable after characterization. Atomic force microscopy, particularly when operated in the tapping mode, is likewise time-consuming and suffers from certain anomalies caused by an improperly chosen set point, that is, free amplitude in air for the cantilever. Raman spectroscopy is a quick characterization method for identifying one to a few layers, but the laser irradiation causes structural degradation of the $MoS_2$. Optical microscopy works only when $MoS_2$ is on a silicon substrate covered with $SiO_2$ of 100~300 nm thickness. The last two optical methods are commonly limited in resolution to the micrometer range due to the diffraction limits of light. We report here a method of measuring the distribution of the number of $MoS_2$ layers using a low voltage field emission electron microscope with acceleration voltages no greater than 1 kV. We found a linear relationship between the FESEM contrast and the number of $MoS_2$ layers. This method can be used to characterize $MoS_2$ samples at nanometer-level spatial resolution, which is below the limits of other methods.

크립토스포리디움의 활성/감염성 판별법을 이용한 오존 및 자외선 소독능 평가 (Evaluation of Cryptosporidiurn Disinfection by Ozone and Ultraviolet Irradiation Using Viability and Infectivity Assays)

  • 박상정;조민;윤제용;전용성;임연택;진익렬;정현미
    • 생명과학회지
    • /
    • 제16권3호
    • /
    • pp.534-539
    • /
    • 2006
  • 크립토스포리디움은 염소내성이 매우 강해 일반적인 표준정수처리공정의 소독으로는 제거가 불가능하다. 따라서 본 연구에서는 오존 및 UV를 이용한 단위소독공정에서 DAPI/PI 및 in vitro excystation을 이용하여 크립토스포리디움 불활성화를 평가하였으며, 또한 오존을 이용한 고도산화처리 파일럿에서는 세포배양법을 이용하여 크립토스포리디움 불활성화를 평가하였다. 오존 소독연구는 50 mL 용량의 piston type batch reactor에서 용존오존을 자동적으로 측정해주는 flow injection analysis (FIA) 시스템을 이용하여 실험한 결과, 1 log 제거에 필요한 CT값은 $25^{\circ}C$에서 DAPI/PI 및 in vitro excystation에 의해 각각 약 1.8, 2.2 $mg/L{\cdot}min$으로 나타났으며, 2 log 제거에 필요한 CT값은 각각 약 3.2, 3.8 $mg/L{\cdot}min$으로 나타났다. 또한 $5^{\circ}C$에서 크립토스포리디움 1 log 제거에 필요한 CT값은 DAPI/PI 방법에 의해 약 9.1 $mg/L{\cdot}min$으로 나타났으며, 2 log제거에 필요한 CT값은 14.8 $mg/L{\cdot}min$로 나타나, 같은 소독효과를 나타내기 위해서 저온에서는 상온에서보다 요존 요구량이 약 $4{\sim}5$배 정도 증가하여야 함을 확인하였다. 40 L규모의 오존 반응조를 이용한 파일럿 실험에서는 정수처리공정상 모래여과를 거친 물에 살아있는 크립토스포리디움을 접종한 것을 시료로 하여 연속적으로 흐르게 한 다음, 오존량을 변화시키고 체류시간은 5분으로 고정하여 불활성화를 평가하였다. 실험결과, 8 $mg/L{\cdot}min$의 CT값에서 DAPI/PI 및 excystation과 같은 생사판별법을 이용하였을 경우에는 약 0.2 log정도의 불활성화를 나타내었으며, 세포감염시험법을 이용하였을 경우에는 약 1.2 log정도의 불활성화를 나타냈다. 오존에 의한 크립토스포리디움의 소독능 평가에 단위공정 및 파일럿 실험 모두 2가지 생사판별법(DAPI/PI와 excystation) 사이에는 큰 차이를 나타내지 않았으나, 생사판별법과 세포감염시험법 사이에는 현저한 차이를 나타내었는데, 이는 세포감염시험법으로 측정하는 sporozoite 및 merozoite로의 분화과정이 생사판별법이 근거한 세포벽의 구조와 기능 유지 보다 더 오존 소독에 더 민감함을 알 수 있었다. 파일럿 실험에서의 CT값이 piston batch reactor에서의 CT값 보다 낮게 나타난 것은 파일럿 실험에서 수작업으로 인한 용존 오존 측정이 정밀하지 못하여 IOD가 농도에 반영되지 않았고, 반응조 규모(50 mL vs 40 L) 및 형태(회분식 vs 연속식)의 차이에 기인하는 것으로 여겨진다. 한편, UV를 이용한 단위공정에서는 크립토스포리디움 1, 2 log 제거에 필요한 IT값은 $25^{\circ}C$에서 각각 DAPI/PI 방법에 의해 약 25, 50 $mWs/cm^2$로 나타났으며, $5^{\circ}C$에서의 크립토스포리디움 1, 2 log제거에 필요한 IT값은 약 40, 80 $mWs/cm^2$로 나타났다. 온도 $20^{\circ}C$ 감소 시 약 60% 정도의 IT값이 더 필요한데, 이것은 저온에서는 약한 자외선을 발산하는 저압저출력 UV 램프의 특성 때문인 것으로 사료되었다.