• 제목/요약/키워드: Twist drill

검색결과 34건 처리시간 0.022초

3차원절삭에 관한 연구(초경DRILL의 효율성 증가) (A Study of Three Dimension Cutting;Tipped Twist Drilling)

  • 이영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.168-170
    • /
    • 1994
  • Carbide-tipped twist drill of new type which is better than traditional H.S.S twist drill has been developed successfully to drill steel work-pieces with high speed. This new carbide drill consists of a characteristic flature of special shape of cutting edge, chip pocket, and flute. The special design of the chip pocket and the flute guarantees both periodic fracture and smooth transport of chips along the flute. The carbide-tipped twist drill also allows one to apply more drilling force than conventional one and produce holes with high accuracy.

  • PDF

두 가지 임플란트 드릴 조합에 따른 온도 변화 및 효율 비교 (Temperature change and performance of bur efficiency for two different drill combinations)

  • 황보흥;박재영;이상윤;손큰바다;이규복
    • 대한치과보철학회지
    • /
    • 제60권2호
    • /
    • pp.143-151
    • /
    • 2022
  • 목적: 본 연구의 목적은 두 가지 다른 임플란트 드릴 조합을 사용하여 열 발생과 드릴링 시간에 따른 성능 효율성을 평가하는 것이다. 재료 및 방법: 본 연구에서는 소갈비뼈를 연구재료로 사용하였다. 표본을 시험하기 위해 소의 뼈에서 근막 및 근육을 제거하고 드릴링 영역 주위에 온도 센서를 장착했고, 드릴링 후 온도 및 시간을 측정하였다. 실험군은 이니셜 드릴 전에 사용하는 드릴에 따라 가이드 드릴 사용 그룹과 린드만 드릴 사용 그룹으로 나누었다. 가이드 드릴 사용 그룹의 드릴 사용 순서는 다음과 같다; guide drill (ø 2.25), initial drill (ø 2.25), twist drill (ø 2.80), 그리고 twist drill (ø 3.20). 린드만 드릴 사용 그룹의 드릴 사용 순서는 다음과 같다; Lindmann drill (ø 2.10), initial drill (ø 2.25), twist drill (ø 2.80), 그리고 twist drill (ø 3.20). 통계적 분석은 Mann-Whitney U test 및 Friedman test를 이용하여 집단간 차이를 분석하였다 (α = .05). 결과: 가이드 드릴 사용 그룹의 각 시편에 대한 평균 성능 효율은 0.3861 - 1.1385 mm3/s 범위를 보였고, 린드만 드릴 사용 그룹의 평균 성능 효율은 0.1700 - 0.4199 mm3/s를 보였다. 가이드 드릴을 사용한 드릴 조합은 드릴링 시간으로 계산했을 때 우수한 성능 효율을 보였다 (P < .001). 결론: 가이드 드릴 사용 그룹이 린드만 드릴 사용 그룹보다 우수한 성능 효율을 보였기 때문에, 1차 드릴링을 수행하는 과정에서 가이드 드릴의 사용이 더욱 적합하였다.

사체의 장골에서 수용부 형성방법에 따른 임플란트 일차 안정성 (PRIMARY STABILITY OF IMPLANTS IN ILIUM OF CADAVER BY THE METHODS OF RECIPIENT SITE PREPARATION)

  • 심정우;조진용;국민석;박홍주;오희균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권2호
    • /
    • pp.180-186
    • /
    • 2008
  • Purpose: This study was performed to evaluate the effect of the implant recipient site preparation methods on primary stability of implants with the instruments of $Osstell^{TM}$ and $Periotest^{(R)}$ in the iliac bone of cadaver. Methods and materials: The 8 iliac bones in 4 cadavers and implants treated with resorbable blasting media (RBM) were used. $Periotest^{(R)}$ (Simens AG, Germany) and $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden) were used to measure primary stability of implants. Implants were inserted into the iliac crest of the cadaver. In control group, the recipient site was prepared according to the manufacturer's recommendation: 1.8 mm guide drill, 2.0 mm initial drill, 2.7 mm pilot drill, 2.7 mm twist drill, 3.0 mm twist drill, 3.3 mm pilot drill, 3.3 mm twist drill, and 3.3 mm countersink drill as well as tapping drill were used in order. In the group 1, implant recipient sites were prepared by sequentially drilling from 1.8 mm guide drill to 3.0 mm twist drill and then inserted implants without countersinking and tapping. In the group 2, implant recipient sites were prepared to 3.0 mm twist drill and countersink drill and then inserted implants without tapping. In the group 3, the sites were prepared to 3.0 mm twist drill and countersink drill as well as tapping drill. In the group 4, the sites were prepared to 3.3 mm twist drill. In the group 5, the sites were prepared to 3.3 mm twist drill and countersink drill. A total of 60 implants were placed (n=10). The stability was measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally and buccolingually. To compare the mean stability of each group statistically, One-way ANOVA was used and correlation of instrument were analyzed using SPSS 12.0. The results obtained were as follows; 1. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ buccolingually showed the highest, and there are significant difference statistically between control group and experimental group 1,2,4 in each instruments respectively (p<0.05). 2. The stability of group 1 measured using $Osstell^{TM}$ and $Periotest^{(R)}$ mesiodistally showed the highest. There are significant difference statistically between control group and all experimental groups in $Osstell^{TM}$, and between control group and experimental group 1,2,3,4 (p<0.05). 3. There are high correlation between the measurements of $Osstell^{TM}$ and $Periotest^{(R)}$ (p<0.05). Conclusion: These results indicate that the primary stability of implant can be obtained by the recipient sites preparation with smaller diameter drill than that of implant or minimal drilling.

Force Prediction and Stress Analysis of a Twist Drill from Tool Geometry and Cutting Conditions

  • Kim, Kug-Weon;Ahn, Tae-Kil
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권1호
    • /
    • pp.65-72
    • /
    • 2005
  • Drilling process is one of the most common, yet complex operations among manufacturing processes. The performance of a drill is largely dependent upon drilling forces, Many researches focused on the effects of drill parameters on drilling forces. In this paper, an effective theoretical model to predict thrust and torque in drilling is presented. Also, with the predicted forces, the stress analysis of the drill tool is performed by the finite element method. The model uses the oblique cutting model for the cutting lips and the orthogonal cutting model for the chisel edge. Thrust and torque are calculated analytically without resorting to any drilling experiment, only by tool geometry, cutting conditions and material properties. The stress analysis is performed by the commercial FEM program ANSYS. The geometric modeling and the mesh generation of a twist drill are performed automatically. From the study, the effects of the variation of the geometric features of the drill and of the cutting conditions of the drilling on the drilling forces and the stress distributions in the tool are calculated analytically, which can be applicable for designing optimal drill geometry and for improving the drilling process.

임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구 (A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION)

  • 김평일;김영수;장경수;김창회
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

다면 드릴의 성능 해석과 최적화 (Analysis of multi-facet drill(MFD) performance and optimization of MFD geometry)

  • 이상조;윤영식
    • 대한기계학회논문집
    • /
    • 제14권6호
    • /
    • pp.1523-1532
    • /
    • 1990
  • 본 연구에서는 다면드릴을 연구 대상으로 하여 다면 드릴의 기하학적 형상인 자들을 이용하여 드릴 작업시 추력과 토크를 예측하는 데 적합한 절삭력 예측 모델을 유도하였으며, 추력과 토크를 최소화하는 방향으로 다면드릴의 각 형상인자를 최적화 하였다.

드릴의 선단각, 나선각 및 가공조건이 가공성에 미치는 영향 (The Effect of Drill Helix Angle, Point angle, and Cutting Conditions on the Drilling Performance)

  • 이영식
    • 한국생산제조학회지
    • /
    • 제6권4호
    • /
    • pp.138-146
    • /
    • 1997
  • The optimal drill helix angle, point angle, and cutting conditions are recommended in the study so as to maximize the drilling performance by investigating the experimental reaults concerning with the state of chip formation, roundness of machined holes, and geometry of projected burr at hole exit, which are examined under the conditions of various helix angles, drill point angles of twist drill, cutting speeds, and feeds in operional parameters. In the easiness of chip escape, the helical type of chip is producted when a helix angle is 30$^{\circ}$, drill point angle 118$^{\circ}$, 140$^{\circ}$and feed is st between 0.1 and 0.15mm/rev. Roundness of machined hole is improved when the helix angle is 37$^{\circ}$, drill point angle is 118$^{\circ}$, and feed is 0.15mm/rev. The height of projected burr at the button of machined hole increases when the drill point angle and helix angle becomes large.

  • PDF

트위스트 드릴제작을 위한 나선형 홈가공의 기하학적인 해석 (Geometrical Analysis of Helical Groove Machining for Manufacture of Twist Drill)

  • 고성림
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1643-1653
    • /
    • 1994
  • To facilitate the manufacturing of dull using CNC grinding machine, the simulation of helical groove machining with given wheel profile and setting condition is necessary. Considering the wheel as a collection of thin disks, the flute configuration is predicted in a cross section perpendicular to the axis and the grinding wheel profile is also predicted to machine the desired helical groove with given setting conditions. Two programs for these processes are developed. Using programs interactively, the helical groove machining process can be predicted more accurately. By clarifying the geometrical relation between the shape of cutting edge and the flute configuration in the cross section which is perpendicular to drill axis, it becomes possible to predict the necessary cross sectional shape of wheel for desired drill cutting edge shape. Some factors for the software are considered concerning prediction of accuracy and computing time.

머신비전 시스템을 이용한 마이크로드릴 마멸의 상태감시 (Monitoring of Micro-Drill Wear by Using the Machine Vision System)

  • 최영조;정성종
    • 대한기계학회논문집A
    • /
    • 제30권6호
    • /
    • pp.713-721
    • /
    • 2006
  • Micro-drill wear deteriorates accuracy and productivity of the micro components. In order to improve productivity and qualify of micro components, it is required to investigate micro-drill wear exactly. In this study, a machine vision system is proposed to measure the wear of micro-drills using a precision servo stage. Calibration experiments are conducted to compensate for the machine vision system. In this paper, worn volume, area and length are defined as wear amounts. Micro-drill wear is reconstructed as the 3D topography and the quantized wear amount by using the shape from focus (SFF) method and wear parameters. Experiments have been conducted with HSS twist micro-drills and SM45C carbon steel workpieces. Validity of the proposed machine vision system is confirmed through experiments.

TiAlN 코팅드릴의 구멍가공특성에 관한 연구 (A Study on the Drilling Characteristics of a TiAlN Coated Twist Drill)

  • 김태영;신형곤;김종택;김민호;이한교
    • 한국기계가공학회지
    • /
    • 제3권4호
    • /
    • pp.29-36
    • /
    • 2004
  • An experimental study on drilling of stainless steel is conducted using TiAlN coated drills and HSS twist drills with several cutting conditions; feed rate, spindle rotational speed, and dry/wet cutting. The effects of number of hole on the thrust force are examined by cutting force measurement. The flank wear of the drills and the change of hole diameter are quantitatively observed using a vision system. It is found that the thrust force in drilling with TiAlN coated drills decrease under dry and wet machining, whereas the flank wear resistance is improved.

  • PDF