• Title/Summary/Keyword: Twin-Fluid Atomization

Search Result 51, Processing Time 0.029 seconds

Prediction of Mean Diameters Based on the Instability Theory for Twin Fluid Nozzle (불안정 이론을 이용한 2유체 노즐에서의 분무입경 예측)

  • Kim, Gwan-Tae;An, Guk-Yeong;Kim, Han-Seok
    • 연구논문집
    • /
    • s.25
    • /
    • pp.47-54
    • /
    • 1995
  • The atomizing characteristics in a spray injected from a twin fluid atomization nozzle have been investigated. The Sauter mean diameters as mean diameter are compared with wavelength calculated from the instability theory. The Sauter mean diameter are measured by the Fraunhofer diffraction theory using the Malvern particle sizer. The wavelength is calculated using the mean relative velocity instead of the exit relative velocity of nozzle. Also shadowgraphy technique is used to visualize atomization. This paper gives a possibility that the mean diameter can be predicted with the wavelength obtained by the simple instability theory.

  • PDF

Prediction of Mean Diameters Based on the Instability Theory for Twin Fluid Nozzle (불안정 이론을 이용한 2유체 노즐에서의 분무입경예측)

  • Kim, Kwan-Tae;Ahn, Kook-Young;Kim, Han-Seok;Ryu, Jeong-In
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.1
    • /
    • pp.57-64
    • /
    • 1996
  • The atomizing characteristics in a spray injected from a twin fluid atomization nozzle have been investigated. The Sauter mean diameters as mean diameter are compared with wavelength calculated from the instability theory. The Sauter mean diameter are measured by the Fraunhofer diffraction theory using the Malvern particle sizer. The wavelength is calculated using the mean relative velocity instead of the exit relative velocity of nozzle. Also shadowgraphy technique is used to visualize atomization phenomena. This paper gives a possibility that the mean diameter can be predicted with the wavelength obtained by the simple instability theory.

  • PDF

Correlation between size and velocity of drops in a spray from an internal mixing twin-fluid atomizer (내부혼합형 이류체 분사노즐에서 발생한 분무내 액적들의 크기와 속도의 상관관계)

  • Kim, Sang-Jin;Hiroyasu, H.
    • Journal of ILASS-Korea
    • /
    • v.3 no.1
    • /
    • pp.27-33
    • /
    • 1998
  • Correlations of drop size and velocity in a spray from the disintegration of liquid jet and liquid film from an internal mixing twin-fluid atomizer, were determined by phase Doppler method. The distribution pattern of Sauter mean diameter(SMD) in a spray was changed by a behavior of liquid flow. As smaller droplets became faster and slower easily by the surrounding conditions, the correlation between drop size and mean velocity was found to be varied as next 3 steps; firstly smaller droplets have a higher mean velocity at the area near atomizer, droplets have almost the same mean velocity and finally larger droplets have a higher mean velocity at the area far from an atomizer.

  • PDF

Spray characteristics and nozzle design experiment to twin-fluid atomizer (이유체 분무기의 분무특성 및 노즐설계 실험)

  • Jeong, Jin-Do;Ji, Pyeong-Sam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.1941-1947
    • /
    • 1996
  • Droplet size measurement technique was established for the sprayed viscous fluid by virtue of the installation of the sprayed-droplet size measurement system employing light scattering method. Atomization test results showed that the mean droplet size of the sprayed viscous fluid is decreased with the increase of the mass ratio of air to fuel and in case of the same air/fuel ratio, also with the increase of viscous fluid flow rate, and is increased with the distance from atomizer tip. Basic design data for the manufacture of external-mixing type, Y-Jet type, and internal-mixing type atomizers was acquired from the atomization tests.

Pulverized Coal Particle Presence Inside CWM Droplet (CWM 방울안의 미분탄 존재)

  • 김종호;김성준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1211-1221
    • /
    • 1990
  • The purpose of this study is to get experimental data on the distribution of CWM (Coal- Water Mixture) droplets size and the presence of pulverized coal particles inside CWM droplets. Atomization of CWM is done by Twin-Fluid Atomizer. The operational parameters are atomizing air pressure, coal particle loading, mean size of pulverized coal particles and sampling positions across spray. Th data analysis is initiated by Impression Sampling Method(Magnesium Oxide Technique) and Photo-technique and counting works are followed. Experimental work induces following research results. The variation of particle loadings in slurry makes no appreciable effects on the mean size of CWM droplets. It is evident that atomizing air pressure has very strong effect on the atomization of slurry. The mean size of atomized fuel droplets is dramatically reduced with the increasing air pressure. The population ratio of droplets without coal particles to total number of droplets is decreased as atomizing air pressure or loading rises and the same trend is obtained as the mean size of coal particles becomes smaller but a certain tendency of coal particle presence inside droplets could not be found from the change of sampling positions.

An Experimental Study on the Drop Size of a Twin-Fluid Swirl Jet Nozzle (이유체 선회분사 노즐의 액적크기에 관한 실험적 연구)

  • Oh, J.H.;Kim, W.T.;Kang, S.J.;Rho, B.J.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 1996
  • This experimental study was to investigate spray angles and drop sizes in an external mixed twin-fluid swirl jet nozzle. Twin-fluid swirl jet nozzle with swirlers designed four swirl angles such as $0^{\circ},\;22.5^{\circ},\;45^{\circ},\;64.2^{\circ}$ was employed. A PDA system was utilized for the measurement of drop size and mean velocity. Water and air were used as the working fluids in this experiment. The mass flow rate of water was fixed as 0.03 kg/min, and air flow rates were controlled to have the air/liquid mass ratio from 1.0 to 6.0. As a result, swirl angle controlled to spray angles and drop sizes. It was found that swirl angle was increased with spray angle and with decreased SMD. However, the effect of swirl angle was reduced at large air/liquid mass ratio(Mr=6.0).

  • PDF

Performance Evaluation of Automatic Self-Cleaning Filter System using Twin-Fluid Nozzles for Air Cleaning in the Subway Stations (지하철 공기청정을 위한 2유체노즐형 자동세정 공기청정 시스템 개발에 관한 연구)

  • Ahn, Y.C.;Lee, J.K.
    • Journal of ILASS-Korea
    • /
    • v.9 no.3
    • /
    • pp.15-21
    • /
    • 2004
  • The removal of the dusts in the subway stations, tunnels, factories and buildings becomes issue for comfortable indoor and outdoor conditions. There has been used an automatic self-cleaning filter system to collect the dusts. In general, the collected particles are removed by water spray nozzles. The new design for improving the cleaning efficiency of collected dusts and reducing the supplied water is the concept of the plane array of demister filters and the twin-fluid nozzle for mixing compressed air and water in the automatic self-cleaning filter system. Results show that the cleaning efficiency of twin-nozzle filter systems is 99.1%, compared to 47% in the conventional filter system. Therefore the automatic self-cleaning filter system using twin-fluid nozzle filter systems reduces water supplied in the filter system, and increases cleaning efficiency and drying efficiency.

  • PDF

A Study on the Effect of Atomization of Pressure Nozzle with Blower - Air (압력식 노즐에서 송풍공기가 미립화에 미치는 영향에 관한 연구)

  • Koh, Kyoung-Han;Lim, Sang-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.5
    • /
    • pp.283-288
    • /
    • 2012
  • This study was undertaken to investigation the spray characteristics of the twin fluid atomization nozzle system. The light oil was injected at the normal temperature and injection pressure was 5 bar - 10 bar by 1 bar and volume flow was 0.5, 1.0 and 2,0 mmH2O(X10-2). We measured the SMD of sprayed droplet to study spray characteristics. The following conclusions were reached from the results of these study. 1. The more injection pressure increased, the more SMD decreased. 2. The more measuring distance between pressure nozzle tip and analyser beam increased, the more SMD increased. 3. SMD of the blower-air-added injection system were shown, increasing volume flow decreased respectively. The result of this study indicated the blower-air-added injection system induced beneficial changes in SMD. And it will be considered important indicator for spray characteristics design and performance evaluation of twin fluid atomization nozzle system.

A STUDY ON HTGH-EFFICIENCY ATOMIZATION OF MOLTEN MATERIALS (PART 3 : MECHANISM AND CHARACTERISTICS OF ATOMIZATION) (Atomize법에 의한 용융소재의 고효율 미세화에 관한 연구 (제3보 : 애토마이저의 미립화 기구와 특성))

  • Oh, J.G.;Kwon, S.I.
    • Journal of ILASS-Korea
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 1999
  • An experimental study of twin-fluid atomization for powder metallurgy has been conducted using a specially designed atomizer in which liquid is first spread into a thin sheet and then exposed on both sides to high-velocity air. Inner air jet worked for supplying liquid and outer air jets disintegrated liquid sheet. The first result of this study were confined to the effect of atomizing quality through experiments with water. The experimental data will be extend to include the influence of atomizing air velocities on mean particle size through experiments with molten material. An experimental equation on the relationship between SMD and the related parameters was taken out; $$SMD=0.00302\frac{{(\sigma_L\;\rho_L\;D_L)}^{0.5}}{\rho_A(V_1+1.155\;V_2)/2}(1+\frac{W_L}{(W_{A1}/3.33)+W_{A2}})+0.0148(\frac{{\mu_L}^2}{\sigma_L\;\rho_L})^{0.425} \;{D_L}^{0.575}(1+\frac{W_L}{(W_{A1}/3.33)+W_{A2}})^2$$.

  • PDF

Development of an external twin-fluid nozzle for Selective Catalytic Reduction (선택적 촉매 환원법을 위한 외부 혼합형 이유체 노즐 개발에 대한 실험적 연구)

  • Park, J.K.;Lee, C.W.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.24-33
    • /
    • 2004
  • The effect of the working fluid flow conditions and nozzle geometry on the spray performance of a twin-fluid nozzle used in Selective Catalytic Reduction is investigated experimentally. The liquid pressure is varied in the range of 0.3atm to 1.5atm and the air pressure is varied from the 0.5atm to 3.0atm. relative position between liquid nozzle(internal nozzle) and air nozzle(external nozzle) tip changes front 1mm inside the air nozzle to 1mm outside the air nozzle. The orifice diameter of the air nozzle is varied with 5mm. 6mm and 7mm. Spray visualization is realized with CCD-Camera. SMD(Sauter Mean Diameter) and mean particle velocities are measured by PDPA(Phase Doppler Particle Analyzer) under various experimental conditions. The measuring point is 300mm away from the nozzle tip in the downstream spray. The experimental results are that spray angle is depended air flow rate because nozzle diameter, air pressure and nozzle tip relative positions are related air flow rate. SMD is depended air flow rate and water flow rate. Also, SMD is increased when water flow rate is bigger. SMD is decreased when Air flow rate is bigger.

  • PDF