• 제목/요약/키워드: Twin test cell

검색결과 9건 처리시간 0.027초

동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석 (Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell)

  • 강은철;박용대;이의준;윤태권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

Evaluation of Metals (Al, Fe, Zn) in Alternative Fuels by Electrochemical Impedance Spectroscopy in Two Electrode Cell

  • Song, Yon-Kyun;Lim, Geun-Woong;Kim, Hee-San
    • Corrosion Science and Technology
    • /
    • 제9권2호
    • /
    • pp.92-97
    • /
    • 2010
  • Many kinds of alternative fuels such as biodiesel, ethanol, methanol, and natural gas have been developed in order to overcome the limited deposits in fossil fuels. In some cases, the alternative fuels have been reported to cause degrade materials. The corrosion rates of metals were measured by immersion test, a kind of time consuming test because low conductivity of these fuels was not allowed to employ electrochemical tests. With twin two-electrode cell newly designed for the study, however, electrochemical impedance spectroscopy (EIS) test was successfully applied to evaluation of the corrosion resistance ($R_p$) of zinc, iron, aluminum, and its alloys in an oxidized biodiesel and gasoline/ethanol solutions and the corrosion resistance from EIS was compared with the corrosion rate from immersion test. In biodiesel, $R_p$ increased in the order of zinc, iron, and aluminum, which agreed with the corrosion resistance measured from immersion test. In addition, on aluminum showing the best corrosion resistance ($R_p$), the effect of magnesium as an alloying element was evaluated in gasoline/ethanol solutions as well as the oxidized biodiesel. $R_p$ increased with addition of magnesium in gasoline/ethanol solutions containing chloride and the oxidized biodiesel. In the mean while, in gasoline/ethanol solutions containing formic acid, Al-Mg alloy added 1% magnesium had the highest $R_p$ and the further addition of magnesium decreased $R_p$. It can be explained with the fact that the addition of more than 1% magnesium increases the passive current density of Al-Mg alloys.

소형 수소추진선박 기술 개발 및 실증 (The Technology Development and Substantiation of Small Hydrogen Powered Vessel)

  • 임재완;이세준;윤상진;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제34권6호
    • /
    • pp.555-561
    • /
    • 2023
  • In this study, we proposed a standard model for the design, construction and demonstration of the technology development and substantiation of small hydrogen powered vessel in order to respond to the alternative fuel-using vessel market that requires the use of low-carbon/carbon-free fuel as a greenhouse gas reduction measure. The hydrogen fuel cell-based electric propulsion system developed through this is optimized through performance and durability tests on the land-based test site (LBTS), and the electric propulsion system applied to this result is mounted on a small hydrogen propulsion vessel and operated. Simultaneously, through the digital twin technology between the LBTS and the hydrogen-propelled vessel on the sea, the technology that can predict and diagnose the problems that can occur in the electric propulsion system of the vessel is applied to carry out the empirical study of the hydrogen-propelled vessel. In addition, we propose a commercialization model by analyzing the economic feasibility of the demonstration vessel.

SRAM 소자의 Cell Latch-up 현상 분석 (Analysis of Cell Latch-up Effect in SRAM Device)

  • 이준하;이흥주
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2004년도 추계학술대회
    • /
    • pp.203-205
    • /
    • 2004
  • A soft error rate neutrons is a growing problem for terrestrial integrated circuits with technology scaling. In the acceleration test with high-density neutron beam, a latch-up prohibits accurate estimations of the soft error rate (SER). This paper presents results of analysis for the latch-up characteristics in the circumstance corresponding to the acceleration SER test for SRAM. Simulation results, using a two-dimensional device simulator, show that the deep p-well structure has better latch-up immunity compared to normal twin and triple well structures. In addition, it is more effective to minimize the distance to ground power compared with controlling a path to the $V_{DD}$ power.

  • PDF

SRAM소자의 Cell Latch-up 효과에 대한 해석 연구 (A Study of Cell Latch-up Effect Analysis in SRAM Device)

  • 이흥주;이준하
    • 한국산학기술학회논문지
    • /
    • 제6권1호
    • /
    • pp.54-57
    • /
    • 2005
  • 반도체 소자 면적의 축소에 따라 중성자의 소프트 에러율은 집적회로 설계시 큰 문제점으로 대두되고 있다. 고전류 중성자 빔에 의한 가속 실험에서, 래치-업 현상은 소프트 에러 발생율의 정확한 예측을 방해하는 요소로 작용하고 있다. 본 연구는 SRAM 소자의 SER 가속 실험시 발생하는 래치-업에 대한 효과를 분석하였다. 2차원 소자 시뮬레이터를 이용한 시뮬레이션 환경하에서의 결과 깊은 p-well 구조의 기판이 이중 또는 삼중 well 구조에 비하여 양호한 래치-업 방지 효과를 나타내었다. 또한 접지에 대한 $V_{DD}$ 전력선까지의 거리를 최소화하는 것이 효과적인 설계 기법으로 평가되었다.

  • PDF

양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구 (Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving)

  • 강은철;이의준;민경천
    • 한국지열·수열에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

이중 블라인드 광파이프 주광 조명시스템 효율 및 조명에너지 절감량 평가 연구 (Evaluation Study of a Double Blind Light Pipe Daylighting System Efficiency and an Illumination Energy Reduction)

  • 강은철;유성연;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제33권1호
    • /
    • pp.89-95
    • /
    • 2013
  • A DBLP(Double blind light pipe) daylight system can be installed at a building exterior wall or roof to replace artificial light during the day time. This system was consisted of a double blind light collector, a mirror duct type light transformer and a prism light pipe distributor. The double blinds were used to track the sun's altitude and azimuth movements to collect the sunlight throughout the day. The sunlight collected by the light collector was reflected on the first mirror and the second mirror and sent to the light pipe through the light transformer. The transformer was designed to deliver the sunlight into the light pipe efficiently. The light distributor plays a role in diffusing the sunlight coming in through the light collector to be used for indoor lighting. In this paper, a DBLP system has been designed, installed and tested at a KIER daylighting twin test cell. The DBLP daylighting system was applied to the experimental test cell which has an indoor area of 2.0 m wide ${\times}$ 2.4 m height ${\times}$ 3.8 m length. The experiment was conducted from January 30 to February 27, 2012, under clear skies and partially cloudy skies. Data was collected from 10:00 am to 16:00 pm every 2 minute and the average was calculated for every 30 minute of the data collection to obtain the system efficiency. The results indicated that the DBLP system efficiency was evaluated as 11.67%. The DBLP system indoor illumination energy reduction was predicted as 0.822 kWh/day. This could replace 4 sets of a 32W fluorescent lamp operating 6.4 hours per a day.

아토피 피부염 유발 NC/Nga mouse에서 도고 온천수 유황 성분의 효과 (Effect of DOGO phreatic water containing sulphur on Atopic Dermatitis in NC/Nga mouse)

  • 장문희;고가연;안요찬;안택원
    • 한방안이비인후피부과학회지
    • /
    • 제26권3호
    • /
    • pp.36-53
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the effects of DOGO phreatic water containing sulphur on Atopic Dermatitis in NC/Nga mouse. Methods : We made DOGO phreatic water removed sulphur using Twin Alternating Sulfate Eater. After making atopic dermatitis caused by sensitizing NC/Nga mouse to DNCB(dinitrochlorobenzene), we made mouse swim in tanks each filled with distilled water, tap water, DOGO phreatic water(contain sulphur), DOGO phreatic water(remove sulphur) for 30minutes everyday. 3weeks later, we analyzed skin clinical score, total IgE levels(by ELISA), WBC differential counting(Neutrophils, Monocytes), absolute cell number of $Neutrophil^+Gr-1^+$, CCR3 mRNA expressions(by Real-time PCR), IL-4, IFN-${\gamma}$ production levels(by ELISA), histologic test(by H&E staining, toluidine blue staining). Results : The results of making NC/Nga mouse induced atopic dermatitis swim in tanks filled with DOGO phreatic water(contain sulphur) are as follows. 1. Skin clinical scores were decreased significantly in comparison to control group. 2. Total IgG levels were decreased significantly in comparison to control group. 3. WBC differential counting(Neutrophils, Monocytes) were decreased significantly in c.mparison to control group. 4. Absolute cell number of $Neutrophil^+Gr-1^+$ were decreased significantly in comparison to control group. 5. CCR3 mRNA expressions were decreased significantly in comparison to control group. 6. IL-4, IFN-${\gamma}$ production levels were decreased significantly in comparison to control group. 7. The epithelial tissue thickness, leucocytes infiltration, erythema, edema, excoriation, scaling, mast cells infiltrations in dorsal skin were decreased in comparison to control group. Conclusions : These results indicate that DOGO phreatic water(contain sulphur) can be used for helping treat atopic dermatitis.

폐암에서 혈중 Cytokeratin 8, 18, 19의 진단적 가치 (Diagnostic Value of Serum Cytokeratin 8, 18 and 19 in Lung Cancer)

  • 최창민;김우진;오진영;강영애;유철규;이춘택;김영환;한성구;심영수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제55권4호
    • /
    • pp.388-394
    • /
    • 2003
  • 배 경 : 지금까지 폐암의 종양표지자로 알려진 것들 중에 최근에는 CK 19뿐만 아니라 폐암에서 많이 발견되는 CK 8, 18에 대해 특이적인 세가지 단클론항체를 이용한 면역방사선계수법(MonoTotal$^{TM}$)이 개발되어 폐암의 진단에 이용할 수 있는 것으로 보고되었다. 따라서 저자들은 Cyfra 21-1에 비교하여 CK 8, 18, 19의 폐암표지자로서의 진단적 가치에 대해 연구하였다. 대상 및 방법 : 2002년 5월 l일부터 2002년 9월 30일까지 서울대학교병원 내과에 입원하여 기관지내시경 또는 객담도말세포검사, 경피적 조직생검으로 확진된 원발성 폐암환자 129명을 폐암군으로 하고 폐암이 배제된 비악성 호흡기 질환자 160명을 환자 대조군으로 연구에 동의한 건강한 성인 57명을 정상 대조군으로 하여 본 연구를 시행하였다. Cyfra 21-1의 측정은 Fujibebio Diagnostics사(USA)의 immnoradiometric assay kit인 Cyfra$^{TM}$ 21-1을 사용하였고 CK 8, 18, 19의 측정은 IDL biotech사의 2-hour immunoradiometric sandwich test kit인 Monototal$^{TM}$을 사용하였다. 결 과 : 폐암의 조직학적 분류에 따른 Monototal의 혈중평균치(mean${\pm}$SD)는 비소세포폐암이 $412.47{\pm}455.45$ U/L, 소세포폐암이 $237.08{\pm}145.15$ U/L로 환자 대조군 $126.54{\pm}95.72$ U/L, 정상 대조군 $63.68{\pm}31.66$ U/L에 비해 유의하게 증가되어 있었다(p<0.01). Monotoal의 정상범위를 정상 대조군의 가장 높은 수치인 188U/L 이내로 하였을때 비소세포폐암의 민감도는 66.4%, 특이도는 81.9%였다. 병기를 I,II군(32명)과 III,IV군(84명)의 두 군으로 나누어 Monototal의 평균을 비교해 보았을 때 각각 $227.6{\pm}185.2$ U/L, $482.9{\pm}506.4$ U/L로 두 군간에 통계적으로 유의한 차이가 있었다(p<0.001). 환자대조군 세부질환별로 Monototal의 평균치를 보면 미만성폐질환 환자군(11명)에서 $298.7{\pm}210.0$ U/L로 환자 대조군 평균치인 $126.54{\pm}95.72$ U/L에 비해 통계적으로 유의하게 높게 측정되었다(p<0.001)(Table 4). 결 론 : cytokeratin 8, 18, 19의 측정은 폐암의 대표적인 종양 표지자중의 하나인 Cyfra 21-1과 비슷한 민감도와 특이도를 보이고 있어 효과적인 종양표지자로 앞으로 사용될 수 있다.