• 제목/요약/키워드: Turn-on

검색결과 5,407건 처리시간 0.037초

Study on changes in electrical and switching characteristics of NPT-IGBT devices by fast neutron irradiation

  • Hani Baek;Byung Gun Park;Chaeho Shin;Gwang Min Sun
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3334-3341
    • /
    • 2023
  • We studied the irradiation effects of fast neutron generated by a 30 MeV cyclotron on the electrical and switching characteristics of NPT-IGBT devices. Fast neutron fluence ranges from 2.7 × 109 to 1.82 × 1013 n/cm2. Electrical characteristics of the IGBT device such as I-V, forward voltage drop and additionally switching characteristics of turn-on and -off were measured. As the neutron fluence increased, the device's threshold voltage decreased, the forward voltage drop increased significantly, and the turn-on and turn-off time became faster. In particular, the delay time of turn-on switching was improved by about 35% to a maximum of about 39.68 ns, and that of turn-off switching was also reduced by about 40%-84.89 ns, showing a faster switching.

DC reactor type 고온호전도 한류기의 턴간 절연 특성 (The Dielectric Characteristics of Turn-to-Turn Insulation for DC Reactor Type HTSFCL)

  • 백승명;정종만;이창화;류엔반둥;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권12S호
    • /
    • pp.1299-1304
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

다이리스터의 Turn-off 모델을 이용한 최적 Snubber 회로 설계 (Design of an Optimum Thyristor Snubber Circuit with Turn-off Model)

  • 김권호;문영현;송중호;최익;김광배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.773-776
    • /
    • 1993
  • The thyristor turn-off model plays an important part in the design of thyristor snubber circuit. However, it is difficult to determine the thyristor turn-off characteristics. In this paper two methods to establish the simple thyristor turn-off model are proposed based on the reverse recovery characteristics given in the data sheets. Using the simple thyristor turn-off model, the optimum thyristor snubber circuit design procedures are presented considering maximum voltage spike, maximum reverse dv/dt, and turn-off loss.

  • PDF

Gate turn on thyristor 역변환장치의 변환전력한계치에 대하여 (The analysis of the conversive limitation of electric energy for the gate turn on thyristor inverter)

  • 천희영
    • 전기의세계
    • /
    • 제17권2호
    • /
    • pp.6-10
    • /
    • 1968
  • The conversive limitation of electric energy for the thyristor inverter is analysed under the boundary conditions which the term of a negative inverse voltage is longer than that of the turn off time of the thyristor under commutation. It is clear that the maximum electric energy conversion is affected by the turn off time of the thyristor, the reactance of a commutation reactor, the capacity of a commutation condenser and the voltage of Direct current source. It is useful for design the thyrister invertor and the motor speed control to apply the above conclusion.

  • PDF

Analysis of Switching Clamped Oscillations of SiC MOSFETs

  • Ke, Junji;Zhao, Zhibin;Xie, Zongkui;Wei, Changjun;Cui, Xiang
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.892-901
    • /
    • 2018
  • SiC MOSFETs have been used to improve system efficiency in high frequency converters due to their extremely high switching speed. However, this can result in undesirable parasitic oscillations in practical systems. In this paper, models of the key components are introduced first. Then, theoretical formulas are derived to calculate the switching oscillation frequencies after full turn-on and turn-off in clamped inductive circuits. Analysis indicates that the turn-on oscillation frequency depends on the power loop parasitic inductance and parasitic capacitances of the freewheeling diode and load inductor. On the other hand, the turn-off oscillation frequency is found to be determined by the output parasitic capacitance of the SiC MOSFET and power loop parasitic inductance. Moreover, the shifting regularity of the turn-off maximum peak voltage with a varying switching speed is investigated on the basis of time domain simulation. The distortion of the turn-on current is theoretically analyzed. Finally, experimental results verifying the above calculations and analyses are presented.

신.구형도마에서 1/1Turn, Tucked 기술수행 시 운동학적 분석 (Comparative Analysis of Kinematics Factors in Performing Techniques of 1/1Turn, Stretched, and Tucked on the Old Vaulting Horse and the New Vaulting Table)

  • 김지태;허성규
    • 한국운동역학회지
    • /
    • 제16권2호
    • /
    • pp.65-73
    • /
    • 2006
  • The aim of this study was to find out the differences of Kinematics factors from touching down the vaulting board to landing when techniques of 1/1Turn and Tucked were performed on the old vaulting horse and on the new vaulting table. Three national representative men gymnasts were sampled for this study. Three dimension motion analyses by means of six Sony PD-150 video cameras with the velocity of 60 fps were used As a result of analyzing the kinematic data from two kind of vaulting table, the following conclusions were made. 1. The performing time from taking off the vaulting horse to landing(phase 4) in the 1/1 Turn technique on the new vaulting table was significantly longer than that of the old vaulting horse, while the time from contacting to taking off the vaulting horse on the new vaulting table was shorter than that of the old vaulting horse in both and the Tucked techniques. 2. The vertical release COG velocity was faster on the new vaulting table compare to the old vaulting horse in the all kind technique. However the horizontal release COG velocity of the 1/1 Turn technique was faster a little in the old vaulting horse compare to the new vaulting table.

Bay길이에 따른 좌회전 용량산정에 관한 연구 (A study on Left turn Capacity by Bay Length)

  • 김정례;김기혁
    • 대한교통학회지
    • /
    • 제20권3호
    • /
    • pp.31-39
    • /
    • 2002
  • 본 연구는 신호교차로의 좌회전 용량을 파악하기 위하여 bay차로를 포함한 좌회전 이동류의 용량산정 모형을 개발하는데 목적이 있다. 본 연구에서는 신호교차로의 혼잡을 완화시키기 위해 설치 운용되고 있는 좌회전 bay 차로의 용량을 파악하여 보다 정확한 용량산정치 적용을 통한 교차로 운영의 분석자료를 제시하고자 한다. 연구방법은 좌회전 bay길이를 20∼120m까지 변화시키며, bay차로와 전용차로에 대한 차두시간을 분석하였다. Bay차로의 용량산정을 위해 차두시간과 차량유출행태 특성에 따라 1구간(출발손실구간:SLP), 2구간(포화차두구간:SFP), 3구간(차로선택구간:LSP)으로 구분하여 분석하였다. 수집된 차두시간 자료로 차량 대기위치순서별로 분석하였다 자료의 통계적 검증을 통하여 구간대별 평균차두시간을 설정한 후, bay길이별 용량산정 모형을 도출하였으며, 이를 이용하여 bay길이별 좌회전 용량을 산출하였다.

턴 온 상태를 고려한 NPT IGBT의 과도 특성 모델링 (Modeling transient characteristics of NPT IGBT including trun-on condition)

  • 류세환;이용국;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.327-330
    • /
    • 2003
  • In this work, current-voltage characteristics with time of NPT(Non-PunchThrough) IGBT is proposed during turn-on and turn-off by using analytical method. From the results, power loss at turn-off dominates the total electrical loss with respect to that at turn-on. The results have been compared with those of PSPICE and show the identical trend of power loss with each other.

  • PDF

New ZVZCT Bidirectional DC-DC Converter Using Coupled Inductors

  • Qian, Wei;Zhang, Xi;Li, Zhe;Jin, Wenqiang;Wiedemann, Jochen
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.11-23
    • /
    • 2019
  • In this study, a novel zero voltage zero current transition (ZVZCT) bidirectional DC-DC converter is proposed by employing coupled inductors. This converter can turn the main switch on at ZVZCT and it can turn it off with zero voltage switching (ZVS) for both the boost and buck modes. These characteristics are obtained by using a simple auxiliary sub-circuit regardless of the power flow direction. In the boost mode, the auxiliary switch achieves zero current switching (ZCS) turn-on and ZVS turn off. Due to the coupling inductors, this converter can make further efficiency improvements because the resonant energy in the capacitor or inductor can be transferred to the load. The main diode operates with ZVT turn-on and ZCS turn-off in the boost mode. For the buck mode, there is a releasing circuit to conduct the currents generated by the magnetic flux leakage to the output. The auxiliary switch turns on with ZCS and it turns off with ZVT. The main diode also turns on with ZVT and turns off with ZCS. The design method and operation principles of the converter are discussed. A 500 W experimental prototype has been built and verified by experimental results.

건축턴키공사 초기 단계에서의 클레임 방지를 위한 클레임요인 분석 및 대응방안에 관한 연구 - 국내공사 사례중심으로 - (A Study of Analyzing Claim Factor and Making Strategies to Prevent Claim in Early Stage for Architectural Turn-key Project - Focusing on Domestic Project -)

  • 윤준선;유병억
    • 한국건축시공학회지
    • /
    • 제6권1호
    • /
    • pp.93-99
    • /
    • 2006
  • In the inner turn key constructions the problems of uniform types are repeatedly occurred, and, especially, many problems happen up to the stage of pre-construction(from a bid to a contract) owing to the specialties of the turn key constructions. So the claim factors of the Korean turn key constructions were abstracted through the literature searches, the site document examinations, the case studies and the interviews with the experts. When the technicians meeting the interior turn key constructions for the first time and working here now are well acquainted with only these factors, many claims will be prevented. By analysing the degree of claims by claims factors through the questionnaires to the experts about the abstracted factors and surveying the amount of the claims through the case studies, what factors exerted how much of influence on the claims was tested and analyzed. Proposing the response devices to the factors affecting the claims much led the technicians in charge of internal turn key constructions to the prevention and the proper solution of the site claims.