• Title/Summary/Keyword: Turbulence promoter

Search Result 23, Processing Time 0.022 seconds

Heat Transfer Enhancement by Trapezoid Rod Array in Impinging Jet System (충돌제트계에서 사다리형 로드 배열에 의한 열전달촉진에 관한 연구)

  • Lim, Tae-Su;Kum, Sung-Min
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.260-267
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of jet flow and heat transfer caused by trapezoid rods array in impinging jet system. In this study, trapezoid rods have been set up in front of flat plate to serve as a turbulence promoter. The bottom width of trapezoid rod was W=4, 8mm and oblique angle were $80^{\circ}$. The space from rods to the heating surface was C=1, 2, 4mm, the pitch between each rods was P=30, 40, 50mm, and the distance from nozzle exit to flat plate was H=100, 500mm. This results were compared with the case without trapezoid rods. As a result, when rods are installed in front of the impinging plate, the acceleration of the jet flow and the eddies due to the rods seem to contribute to the heat transfer enhancement. Among test conditions, the heat transfer performance was best for the condition of W=8mm, C=1mm, P=30mm and H/B=10. The maximum heat transfer rate is about 1.9 times larger than that without trapezoid rods.

  • PDF

A Study on the Heat Transfer Enhancement by Trapezoid Rod Arrays in 2-Dimensional Impinging Jet System (2차원 충돌 분류계에서 사다리형 로드 배열에 의한 열전달 촉진 효과)

  • Lim, Tae-Soo;Kum, Sung-Min;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1659-1666
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of air flow and heat transfer caused by trapezoid rods array in impinging air jet system. Trapezoid rods have been set up on front of flat plate to act as a turbulence promoter. Local Nusselt numbers were determined as a function of three parameters : (a) the space from re(Is to heating surface(C=1, 2, 4mm), (b) the pitch between each rods(P=30, 40, 50mm), (c) the distance from nozzle exit to flat plate(H/B=2, 6, 10). The measurements were compared with those of the experiment without trapezoid rods. As a result, when rods are installed in front of the impinging palate, the acceleration of the flow and the eddies due to the rods seem to contribute to the heat transfer enhancement. Heat transfer performance was best under the condition of C=1mm and as the pitch is 30mm. The maximum rate of heat transfer augmentation is about 1.9 times greater compared to that without trapezoid rods.

Heat Transfer and Flow Characteristics by Trapezoid Rod Array in Impinging Jet System (충돌제트계에서 사다리형 로드 배열에 의한 열전달 및 유동특성)

  • 금성민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.904-913
    • /
    • 2001
  • The objective of this study was to investigate the characteristics of jet flow and heat transfer caused by trapezoid rods array in impinging jet system. In this study, trapezoid rods have been set up in front of flat plate to serve as a turbulence promoter. The bottom width of trapezoid rod was W=4, 8 mm and oblique angle were 80$^{\circ}$. The space from rods to the heating surface was C=1, 2, 4 mm, the pitch between each rods was P=30, 40, 50 mm, and the distance from nozzle exit to flat plate was H=100, 500 mm. This results were compared with the case without trapezoid rods. As a result, when rods are installed in front of the impinging plate, the acceleration of the jet flow and the eddies due to the rods seem to contribute to the heat transfer enhancement. Among test conditions, the heat transfer performance was best for the condition of W=8 mm, C=1 mm, P=30 mm and H/B=10. The maximum heat transfer rate is about 1.9 times larger than that without trapezoid rods.

  • PDF

Study on enhancement of evaporating heat transfer in narrow horizontal annular crevices (좁은 수평 환형 Crevice에서의 증발열전달촉진에 관한 연구)

  • Bae, Sang-Cheol;Kim, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.4
    • /
    • pp.1481-1490
    • /
    • 1996
  • This study is intend to improve flow pattern within evaporator, which is low quality and low mass flux, by installing narrow horizontal annular crevice so that enhance heat transfer coefficient. The motive, which made to study heat transfer enhancement by using narrow annular crevice, came from capillary phenomena and pumping force of generating vapor on refrigerant boiling. Tests were run about 5 models of turbulence promoter with CFC-12, in the range of evaporating temperature (15.deg. C), mass flux (50 to 100 kg/m$\^$2/s), heat flux (3.4 to 6.7 kW/m$\^$2/), quality (0.1 to O.5). It is observed that flow pattern within evaporator is changed closely to semi-annular flow or annular flow, of which refrigerant liquid is reached to the upper side of tube by using narrow annular crevice. When the narrow annular crevice is installed in the evaporator tube, local heat transfer coefficient is generally more improved than that of smooth tube. That fact is according to observed result of flow pattern. It is learned that narrow annular crevice has more efficiency at a low mass flux. At the TP-5, enhancement of heat transfer rate is about 170% compare to that of smooth tube on a low mass flux (50 kg/m$\^$2/s), and it is about 134% on a high mass flux (100 kg/M$\^$2/S), so that we know that it is on a very high condition.

Thermal Flow Characteristics of Impinging Air Jet by Shape of Turbulence Promoter (난류촉진체 형상에 의한 충돌제트의 열유동 특성)

  • Kum, Sungmin;Jho, Shigie;Yu, Byeonghun;Lee, Seungro
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.187-193
    • /
    • 2012
  • In this study, it was experimentally investigated the effect of the clearances distance between the rod and the impinging plate on characteristics of the thermal flow. For the heat transfer enhancement of wall jet region, the right triangle and the square rods were arranged in front of the impinging plate with various clearance distances. As results, the heat transfer enhancement rate of potential core region at H/B=2 was higher than that of transition region at H/B=10. In this experiment range, the maximum heat transfer enhancement rate was about 46 % higher at the square rod with H/B=2 and C=1mm compared with the flat plate. The heat transfer enhancement rate of the right triangle rod was on average about 3 to 8 % higher than that of the square rod, regardless of the clearance.

An Investigation of Angled Discrete Rib-Turbulators for Cooling Enhancement of Gas Turbine Blades (가스 터빈 블레이드 냉각 성능 향상을 위한 경사요철의 단락 효과)

  • Wu, Seong-Je;Lee, Sei-Young;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.782-789
    • /
    • 2001
  • Local heat/mass transfer and friction loss in a square duct roughened with various types of continuous and discrete rib turbulators are investigated. The combined effects of the gap flows of the discrete ribs and the secondary flows are examined for the purpose of the reduction of thermally weak regions and the promotion of the uniformity of heat/mass transfer distributions as well as the augmentation of average heat/mass transfer. The rib-to-rib pitch to the rib height ratio (p/e) of 8 and the rib angles of 90 and 60 deg are selected with $e/D_{h}=0.08$. The vortical structure of the secondary flows induced by the parallel angled arrays are quite distinct from that induced by the cross angled arrays. This distinction influences on heat/mass transfer and friction loss in all the tested cases. The gap flows of the discrete ribs reduce the strength of the secondary flows but promote local turbulence and flow mixing. As a result, the fairly uniform heat/mass transfer distributions are obtained with two row gaps.

  • PDF

Effect of nozzle geometry on heat transfer of confined slot jet impingement on a flat plate with square rods (사각봉이 배열된 슬롯제트 충돌면에서 노즐형상이 열전달에 미치는 영향)

  • Chung, In-Kee;Park, Si-Woo;Ko, Wan-Wook
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.272-277
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated at different nozzle configuration. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) and clearance(c) between square rods and the plate were examined. Measurement of heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region and the sharp-edged orifice nozzle was heigher than squared orifice nozzle.

  • PDF

Heat Transfer Characteristics of Confined Slot Jet Impingement on a Flat Plate with Square Rods (사각봉이 배열된 슬롯제트 충돌면에서의 열전달 특성)

  • Chung, In-Kee;Park, Si-Woo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.119-124
    • /
    • 2000
  • The heat transfer characteristics of confined turbulent slot jet impingement on the flat plate with square rods(turbulence promoter) have been experimentally investigated. The effects of jet Reynolds number (Re=3900, 5800, 7800, 9700), dimensionless slot-to-plate distance(H/B=4, 6, 8) clearance(c) between square rods and the plate, and the length(d) of a side of the square rod were examined. Measurement or heat transfer rate were conducted using naphthalene sublimation technique. When square rods were inserted over the heat transfer surface, heat transfer rate was slightly increased in the wall jet region.

  • PDF

The Effect of Turbulence Promoters on the Mass Transfer in Ultrafiltration (한외여과에서의 물질전달에 대한 난류촉진물체의 영향)

  • Oh, Won-Suhk;Park, Ham-Yong;Lim, Gio-Bin;Kim, Woo-Sik
    • Membrane Journal
    • /
    • v.4 no.4
    • /
    • pp.221-231
    • /
    • 1994
  • The GR51PP(MWCO 50,000) and GR40PP(MWCO 100,000) membranes manufactured by DDS were used in ultrafiltration of dextran(Mw. : 500,000) solution in flat plate ultrafiltration cell filled with various types of turbulence promoters. The flux improvement by using turbulence promoter was higher in laminar flow region than in turbulent flow region. The maximum improvements of permeate flux were foud as 112% and 50% I laminar flow region and turbulent flow region, respectively. Also, the solute rejection of the ultrafiltration membrane was improved by turbulence promoters and its effect was significant in the high transmembrane pressure and laminar flow region. The smaller the spacer mesh size was used, the higher the flux improved, but the pressure drop in ultrafiltration cell also increased. In laminar flow region, pressure drop by the spacer was negligible, but in turbulent flow region it changed significantly depending upon the mesh size of the spacer and therefore, its mesh size must be baken into account in the design of the process. The predicted results of the modified mass transfer correlation had better agreement with experimental results than those of unmodified one, The modified mass transfer correlations for laminar and turbulent flow region are shown as follow. $N_{sh}=0.151(N_{Re})^{0.199}(N_{Sc})^{0.22}(N_{Scm})^{0.197}\;(625 $N_{sh}=0.0165(N_{Re})^{0.428}(N_{Sc})^{0.33}(N_{Scm})^{0.223}\;(5015

  • PDF

Heat/Mass Transfer Augmentation in a Square Duct . Roughened with Angled Discrete Ribs Having Narrow Gaps (정사각 덕트 내에서 열/물질전달 촉진을 위한 경사진 단락 요철의 좁은 틈새 효과)

  • Wu, Seong-Je;Lee, Sei-Young;Choi, Chung;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.150-158
    • /
    • 2002
  • Local heat/mass transfer and friction loss in a square duct roughened with various types of continuous and discrete rib turbulators are investigated. The combined effects of the gap flows of the discrete ribs and the secondary flows are examined for the purpose of the reduction of thermally weak regions and the promotion of the uniformity of heat/mass transfer distributions as well as the ;augmentation of average heat/mass transfer. The rib-to-rib pitch to the rib height ratio (p/e) of 8 and the rib angles of 90° and 60° are selected with e/D$\_$h/=0.08. The vortical structure of the secondary flows induced by the parallel angled arrays are quite distinct from that induced by the cross angled arrays. This distinction influences on heat/mass transfer and friction loss in all the tested cases. The gap flows of the discrete ribs reduce the strength of the secondary flows but promote local turbulence and flow mixing. Consequently, the angled discrete ribs with the small gaps provide a more uniform heat/mass transfer distribution sustaining high average heat/mass transfer.