• Title/Summary/Keyword: Turbine-based Combined Cycle

Search Result 62, Processing Time 0.028 seconds

Review on Performance Analysis Technology of Power Generation Gas Turbine (발전용 가스터빈 성능해석 기술 분석)

  • Kim, Soo Yong;Park, M. R.;Choi, B. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.198-208
    • /
    • 1998
  • For the development of a gas turbine engine, repetitive calculation process to determine design point and off-design performance based on basic design requirements resulted from the market survey is necessary Due attention then, must be given that design process must be carried out within the mechanical limits satisfying conservation laws of mass, work as well as speed equilibrium between the components for maximum performance. It is the purpose of the present study to deal with technical particulars during design point and off-design process of gas turbine engine performance analysis for simple cycle as well as combined cycle.

  • PDF

Performance Characteristics of a Combined Regenerative Ammonia-Water Based Power Generation Cycle Using LNG Cold Energy (LNG 냉열을 이용하는 암모니아-물 복합 재생 동력 사이클의 성능 특성)

  • Kim, Kyounghoon;Oh, Jaehyeong;Jeong, Youngguan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.510-517
    • /
    • 2013
  • The ammonia-water based power generation cycle utilizing liquefied natural gas (LNG) as its heat sink has attracted much attention, since the ammonia-water cycle has many thermodynamic advantages in conversion of low-grade heat source in the form of sensible energy and LNG has a great cold energy. In this paper, we carry out thermodynamic performance analysis of a combined power generation cycle which is consisted of an ammonia-water regenerative Rankine cycle and LNG power generation cycle. LNG is able to condense the ammonia-water mixture at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the thermodynamic models, the effects of the key parameters such as source temperature, ammonia concentration and turbine inlet pressure on the characteristics of system are throughly investigated. The results show that the thermodynamic performance of the ammonia-water power generation cycle can be improved by the LNG cold energy and there exist an optimum ammonia concentration to reach the maximum system net work production.

A Development of EMAS (Easy Maintenance Assistance Solution) for Industrial Gas Turbine (산업용 가스터빈을 위한 정비지원 시스템 개발에 관한 연구)

  • Kang, Myoungcheol;Ki, Jayoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.91-100
    • /
    • 2017
  • The solution was developed for the maintenance decision support of combined cycle power plant gas turbine. The developed solution was applied to MHI501G gas turbine and is, in present, on the process of field test at GUNSAN combined cycle power plant, South Korea. The developed solution provides the calculated result of optimal overhaul maintenance period through following modules: Real Time Performance Monitoring, Model-Based Diagnostics, Performance Trend Analysis, Optimal Overhaul Maintenance Interval, Compressor Washing Period Management, and Blade Path Temperature Analysis. Model-Based Diagnostics module analyzed the differences between the data of gas turbine performance model and the online measurement. Compressor washing management module suggests the optimal point of balancing between the compressor performance and the maintenance cost.

Performance Analysis of a Combined Cycle of Kalina and Absorption Refrigeration for Recovery of Low-Temperature Heat Source (저온 열원의 활용을 위한 칼리나/흡수냉동 복합사이클의 성능 해석)

  • KIM, KYOUNG HOON;KO, HYUNG JONG;JUNG, YOUNG GUAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.490-496
    • /
    • 2018
  • Recently, the power and refrigeration cogeneration based on Kalina cycle has attracted much attention for more efficient utilization of low-grade energy. This study presents a thermodynamic performance analysis of a cogeneration cycle of power and absorption refrigeration based on Kalina cycle. The cycle combines Kalina cycle (KCS-11) and absorption cycles by adding a condenser and an evaporator between turbine and absorber. The effects of ammonia mass fraction and separation pressure were investigated on the system performance of the system. Results showed that the energy utilization of the system could be greatly improved compared to the basic Kalina cycle.

Ratio Optimization Between Sizes of Components of Heat Recovery Steam Generator in Combined Cycle Gas Turbine Power Plants (복합사이클 발전플랜트 폐열회수 보일러의 구성요소 크기비의 최적화)

  • In, Jong-Soo;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.6
    • /
    • pp.403-410
    • /
    • 2009
  • This paper proposes a new approach to find the optimum ratios between sizes of the heat exchangers of the heat recovery steam generator (HRSG) system with limited size to maximize the efficiency of the steam turbine (bottom) cycle of combined cycle power plants (CCPP), but without performing the bottom cycle analysis. This could be achieved by minimizing the unavailable exergy (the sum of the destroyed and the lost exergies) resulted from the heat transfer process of the HRSG system. The present approach is relatively simple and straightforward because the process of the trial-and-error method, typical in performing the bottom cycle analysis for the system optimization, could be avoided. To demonstrate the usefulness of the present method, a single-stage HRSG system was chosen and the optimum evaporation temperature was obtained corresponding to the condition of the maximum useful work. The results show that the optimum evaporation temperature based on the present exergy analysis appears similar to that based on the bottom cycle analysis. Also shown is the dependency of size (NTU) ratios between the heat exchangers on the inlet gas temperature, which is another important factor in determining the optimum condition once overall size of the heat recovery steam generator is given. The present approach turned out to be a useful tool for optimization of the singlestage HRSG systems and can easily be extended to multi-stage systems.

Performance Analysis on Gas Turbine based Oxy-fuel Combustion Power Plants (가스터빈과 순산소 연소를 적용한 발전시스템의 성능해석)

  • Lee, Young-Duk;Lee, Sang-Min;Park, Jun-Hong;Yu, Sang-Seok;Ahn, Kook-Young
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3169-3174
    • /
    • 2008
  • Future power plants will be required to adopt some type of carbon capture and storage (CCS) technologies to reduce their CO2 emissions. One of distinguished CCS techniques expected to resolve the green house effect is to apply the oxy-fuel combustion technique to power plant, and a lot of research/demonstration programs have been going on in the world. In this paper, CO2-capturing power plants based on gas turbine and oxy-fuel combustion are investigated over several types of configurations. As a prior step, simulation model for 500 MW-class combined cycle power plant was set and was used as a reference case. The efficiencies of several power plants was compared and the advantages and disadvanteges was investigated.

  • PDF

Numerical Study on a Poly-Generation Based on Gasification for Retrofit of a Natural Gas Combined Cycle (복합계통 개조를 위한 가스화 폴리제너레이션 시뮬레이션 연구)

  • Seo, Dong-Kyun;Joo, Yong-Jin;Hong, Jin-Phyo;Kim, Kyung-Rae;Lee, Jeong-Bak
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.141-146
    • /
    • 2017
  • In this work, a simulation study on net 500 MW class of Poly-Generation was conducted for the retrofit of an aged natural gas combined cycle. An entrained gasifier which has a capacity of maximum $260,000Nm^3/h$, 50 MW class of a Polymer Electrolyte Membrane Fuel Cell, and H-class Gas Turbine were selected as key processes. After unit design for those employed processes was set up and combined, the simulation was carried out with Gate-Cycle software (Ver. 6.0) for two cases. The selected cases are a retrofit type (Poly-Gen 1) and a new type (Poly-Gen 2). It was found that the efficiency of the retrofit case is 2.7% lower than that of the new case.

Thermal Performance Analysis of Combined Power Plant Using Coal Gas - Development of the Steady-state Model - (석탄가스를 사용하는 복합발전 플랜트의 열성능 해석 -정상상태 성능해석 모델 개발-)

  • 김종진;박명호;안달홍;김남호;송규소;김종영
    • Journal of Energy Engineering
    • /
    • v.5 no.1
    • /
    • pp.8-18
    • /
    • 1996
  • As a part of comprehensive IGCC process simulation, the thermal performance analysis was performed for coal gas firing combined power plant. The combined cycle analyzed consisted of il Texaco gasifier and a low temperature gas cleanup system for the gasification block and a GE 7FA gas turbine, a HRSG and steam turbine for the power block. A steady state simulator called ASPEN(Advanced System for Process Engineering) code was used to simulate IGCC processes. Composed IGCC configuration included air integration between ASU and gas turbine and steam integration between gasifier, gas clean up and steam turbine. The results showed 20% increase in terms of gas turbine power output(MWe) comparing with natural gas case based on same heat input. The results were compared with other study results which Bechtel Canada Inc. performed for Nova Scotia power plant in 1991 and the consistency was identified within two studies. As a result, the analysing method used in this study is verified as a sound tool for commercial IGCC process evaluation.

  • PDF

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (II) : Based on Piping System Stress Analysis (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (II) : 배관 시스템 응력 해석을 이용한 위험도 평가)

  • Yu, Jong Min;Song, Jung Soo;Jeong, Tae Min;Lok, Vanno;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.14-25
    • /
    • 2018
  • The combined cycle power plant has a cycle of operating the gas turbine with fuel, such as natural gas, and then producing steam using residual heat. The fuel gas is supplied to the gas turbine at a level of 4 to 5 MPa, $200^{\circ}C$ through a compressor and a heat exchanger. In this study, the risk assessment method considering the piping system stress was carried out for safe operation and soundness of the gas fuel supply piping system. The API 580/581 RBI code, which is well known for its risk assessment techniques, is limited to reflect the effect of piping stress on risk. Therefore, the systematic stress of the pipeline is analyzed by using the piping analysis. For the study, the piping system stress analysis was performed using design data of a gas fuel supply piping of a combined cycle power plant. The result of probability of failure evaluated by the API code is compared to the result of stress ratio by piping analysis.

Evaluation of Performance and Economics of Organic Rankine Cycle Integrated into Combined Cycle Cogeneration Plant (복합열병합발전소에 적용된 유기랭킨사이클의 성능 및 경제성 평가)

  • Kim, In Seop;Kim, Chang Min;Kim, Tong Seop;Lee, Jong Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • This study aimed to analyze organic Rankine cycle(ORC) which recovers discarded heat from a gas turbine based combined cycle cogeneration(CC-cogen) plant in terms of both performance and economics. The nominal electric power of the CC-cogen plant is around $120MW_e$, and heat for district heating is $153MW_{th}$. The major purpose of this study is to compare various options in selecting heat source of the ORC. Three heat sources were compared. Case 1 uses the exhaust gas from the HRSG, which is purely wasted to environment in normal plant operation without ORC. Case 2 also uses the exhaust gas from the HRSG. On the other hand, in this case, the DH economizer, which is located at the end of the HRSG, does not operate. Case 3 generates power using some of the district heating water which is supplied to consumers. The estimated ORC power generation ranges between 0.3 to 2.3% of the power generation capacity of the CC-cogen plant. Overall, Case 3 is evaluated to be better than other two options in terms of system design flexibility and power generation capacity.