• Title/Summary/Keyword: Tunnel opening

Search Result 146, Processing Time 0.029 seconds

CORRELATION BETWEEN THE OPENING ANGLE OF A LOUVER AND FLOW RATE FOR THE EFFICIENT CONTROL OF A LARGE FAN (대형 팬의 효율적 유량 조절을 위한 루버 개폐각 상관관계)

  • Noh, T.H.;Lee, S.J.;Chang, S.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.10a
    • /
    • pp.272-276
    • /
    • 2007
  • In this paper, we researched a parametric study in flow control system using louver with numerical method. Generally, for the large fans with constant rotational speed, the louver can be used to control the flow rate. The opening and closing of louver can make a some change of flow properties generated by a large fan. To develope the relation between the opening angle of louver and flow rate(or pressure difference), we simulated the flow past the modelled louver installed in a virtual wind tunnel. For the various angles, the mean flow properties are investigated and parameterized with a given boundary condition. The research result can be used directly to design the flow control system of large constant-speed fans, which are often applied to petrolic refinery system.

  • PDF

The inertial coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • v.18 no.1
    • /
    • pp.57-67
    • /
    • 2014
  • For a building with a dominant windward wall opening, the wind-induced internal pressure response can be described by a second-order non-linear differential equation. However, there are two ill-defined parameters in the governing equation: the inertial coefficient $C_I$ and the loss coefficient $C_L$. Lack of knowledge of these two parameters restricts the practical use of the governing equation. This study was primarily focused on finding an accurate reference value for $C_I$, and the paper presents a systematic investigation of the factors influencing the inertial coefficient for a wind-tunnel model building including: opening configuration and location, wind speed and direction, approaching flow turbulence, the model material, and the installation method. A numerical model was used to simulate the volume deformation under internal pressure, and to predict the bulk modulus of an experimental model. In considering the structural flexibility, an alternative approach was proposed to ensure accurate internal volume distortions, so that similarity of internal pressure responses between model-scale and full-scale building was maintained. The research showed 0.8 to be a reasonable standard value for the inertial coefficient.

The Study on Changes of Exhaust Efficiency and Fine Particle Concentration at a Ventilation Opening by a Air Curtain Flow in a Subway Model Tunnel (지하철 모사터널에서 에어커튼을 이용한 환기구의 배기효율 및 미세입자 농도 변화 연구)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin;Jeong, Sang-Hyeon;Kim, Yong-Min;Kim, Jong-Ryul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.614-622
    • /
    • 2011
  • In this study, a new tunnel ventilation method with a high velocity air curtain flow has been investigated for improving the ventilation exhaust efficiency and removing air pollutants in subway tunnels. At upper or lower position right downstream of a main duct connected with a ventilation opening, air curtain flows were suppled into the main duct where the air flow velocity was in the range of 2~6 m/s. Exhaust efficiency was monitored for both cases with and without air curtain flow for different air velocities, locations and injection angles of the air curtain. Particulate matter concentrations (PM10, PM2.5 and PM1.0) were also checked at both the main duct and ventilation opening before and after supplying air curtain flows. Lower air velocity of the main duct flow, higher air velocity of the air curtain led to higher exhaust efficiency and the air curtain condition of 30..inclined injection toward the main flow showed the maximum exhaust efficiency. The exhaust efficiency of about 24% without the air curtain could be improved to about 34% after using the air curtain flow. PM concentration decreased at the main duct and increased at the ventilation opening after using the air curtain flow. Therefore, the suggested method to use air curtain flows in tunnels will be probably one of the promising tools to reduce air pollutants in subway tunnels.

Effect of building volume and opening size on fluctuating internal pressures

  • Ginger, John D.;Holmes, John D.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.361-376
    • /
    • 2008
  • This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

Considerable Parameters and Progressive Failure of Rock Masses due to the Tunnel Excavation (터널 굴착시 고려해야 할 주변앙반의 매개변수와 진행성 파괴)

  • 임수빈;이성민
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.231-234
    • /
    • 1994
  • Concentrated stresses due to the tunnel excavation easily cause failure around opening in the soft rock mass layer. Thus, while excavatng tunnel in the soft rock mass layerm it is very important to predict the possibility of failure or yielding zones around tunnel boundary. There are two typical methods to predict these; 1) the analysis of field monioring data and 2) numerical analysis. In this study, it was attempted to describe the time-dependent or progressive rock mass manner due to the continuous failure and fracturing caused by surrounding underground openings using the second method. In order to apply the effects of progressive failure underground, an iterative technique was used with the Hoek and Brown rock mass failure theory. By developing and simulating, three different shapes of twin tunnels, this research simulated and estimated the proper size of critical pillar width between tunnels, distributed stresses on the tunnel sides, and convergences of tunnel crowns. Moreover, results out progressive failure technique based on the Hoek and Brown theory were compared with the results out of Mohr-Coulomb theory.

  • PDF

Experiments on the Effective Engine Room Ventilation in a Power Car (동력 철도차량 기관실의 효과적인 환기에 관한 실험적 연구)

  • Han, S.Y.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.3
    • /
    • pp.166-176
    • /
    • 1990
  • Experimental study was made to find the effective ways for cooling of engine room in a power car through natural ventilation, forced ventilation and wind tunnel test of 1:10 model. Through the measurements of inner temperature of engine room and pressure distribution of model surface for the various opening combinations and the fan locations, the following results are obtained. For natural ventilation, side and top opening combination is more effective than the side openings only and optimal opening combination is all side openings with top center opening. For forced ventilation with fan on the roof, the combination of all sides and top opening is more effective than the combination of side and top opening, and the optimal location of fan is top center. When the model is located in the air stream, the combination of side and top opening is more effective than the side openings only, and the optimal location of top opening is the front opening. With both air stream and forced ventilation, the optimal location of fan is the side region, and the direction of side grill installation is found to have negligible effect on the room ventilation.

  • PDF

Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel (도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-74
    • /
    • 2016
  • In semi-transverse ventilation system applied for road tunnel, adjustment of the port opening ratio is an essential part for uniform airflow rate per unit length over the entire tunnel. However, it has not been considered decently throughout the design process and operating of the tunnel. Therefore, in this study, we developed a program for the calculation of the opening size ratio of supply or exhaust port in transverse ventilation system and carried out the research to present a management plan for the port. In supply duct system, the opening size of the port had a tendency to increase and then decrease later when it gradually becomes closer toward the bulkhead at the beginning of the duct the minimum opening degree is to appeared as 56%. In the exhaust system, port size is the smallest at the beginning of duct as 15%, has shown a tendency to increase towards the bulk head. As results of estimating the air flow rate for 300 m intervals, the exhaust flow rate in the center of tunnel appeared to be extremely low as 8.1% and 12.5% when port size is constant and is adjusted supply type. Thus, even if the normal ventilation efficiency is declines, yet it is highly recommend adjusting the port size in order to obtain a uniform flow rate at fire accidents.

Wind Tunnel Investigation of Fluctuating Pressure Inside Building (풍하중에 의한 건물내부 압력의 동적변화에 관한 연구)

  • 이경훈
    • Computational Structural Engineering
    • /
    • v.3 no.4
    • /
    • pp.133-141
    • /
    • 1990
  • The nature of fluctuating air pressure inside building was studied by testing a building model in a wind tunnel. The model has a single room and a window opening. Various opening conditions were tested in both laminar uniform wind and turbulent boundary-layer wind. The RMS and the spectra of the fluctuating internal pressure were measured. The test results support a recent theory which predicts the behavior of internal pressure under high wind based on aerodynamic analysis.

  • PDF

Wind tunnel tests on flow fields of full-scale railway wind barriers

  • Su, Yang;Xiang, Huoyue;Fang, Chen;Wang, Lei;Li, Yongle
    • Wind and Structures
    • /
    • v.24 no.2
    • /
    • pp.171-184
    • /
    • 2017
  • The present study provides a deeper understanding of the flow fields of a full-scale railway wind barriers by means of a wind tunnel test. First, the drag forces of the three wind barriers were measured using a force sensor, and the drag force coefficients were compared with a similar scale model. On this basis, the mean wind velocity and turbulence upwind and downwind of the wind barriers were measured. The effects of pore size and opening forms of the wind barrier were discussed. The results show that the test of the scaled wind barrier model may be unsafe, and it is suitable to adopt the full-scale wind barrier model. The pore size and the opening forms of wind barriers have a slight influence on the flow fields upwind of the wind barrier but have some influences on the flow fields and power spectra downwind of the wind barrier. The smaller pore size generates a lower turbulence density and value of the power spectrum near the wind barrier, and the porous wind barriers clearly provide better shelter than the bar-type wind barriers.

A Study on the Stress Induced Brittle Failure around Openings with Cross-sectional Shape by Scaled Model Test and DEM Simulation (모형시험과 개별요소법을 이용한 단면 형상에 따른 공동 주변 취성파괴에 관한 연구)

  • Bae, Seong-Ho;Jeon, Seok-Won;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.17 no.5
    • /
    • pp.389-410
    • /
    • 2007
  • For moderately jointed to massive rock masses, the failure and deformation behaviors around an excavated opening are absolutely influenced by the initial rock stress and strength of in-situ rock mass. The localized and progressive brittle failure around an opening does not mean whole collapse of an excavated opening. But, for many cases, it may induce temporary stopping of excavation works and reexamination of the current supporting system, which can result in delay of the entire construction works and additional construction cost. In this paper, the characteristics of the brittle failure around an opening with stress level and tunnel shape was studied by the biaxial compressive test using scaled specimen and by the numerical simulation with $PFC^{2D}$. The biaxial test results were well coincided with the stress induced failure patterns around the excavated openings observed and monitored in the in-situ condition. For the circular part of the opening wall, the stress induced cracks initially occurred at the wall surface in the direction of the minimum principal stress and contributed to the localized notch shaped failure region having a certain range of angle. But for the corner and straight part of the opening wall, the cracks initiated at sharp corners were connected and coalesced each other and with existing micro cracks. Further they resulted in a big notch shaped failure region connecting two sharp corners.