• Title/Summary/Keyword: Tunnel fires

Search Result 97, Processing Time 0.024 seconds

An Experimental Study of Smoke Movement in Tunnel Fires with Natural Ventilation (터널화재시 자연환기에 의한 연기거동에 관한 실험적 연구)

  • 김충익;유홍선;이성룡;박현태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.247-253
    • /
    • 2002
  • In this study, reduced-scale experiments were conducted to analyze smoke movement in tunnel fire with roof vent. The 1/20 scale experiments were carried out under the Froude scaling using gasoline pool fire ranging from 7.3 to 15.4 cm in diameter with total heat release rate from 1.0 to 8.46kw. In case of 1 m high vent, smoke front reached to the tunnel exit at about 16 sec delayed with ventilation. The delay time grew longer with the vent height. The temperature after the vent was lower than that without the vent. The exit temperature declined maximum of $20^{\circ}C$ after passing the vent. It was confirmed that the thickness of smoke layer was maintained uniformly under the 25% height of the tunnel through the visualized smoke now by a laser sheet and the digital camcorder.

Evaluation of Fire Safety for Road Tunnels in Port Area based on Fire Safety Guidelines (도로터널 화재안전기준 기반 항만 지역 도로터널 화재 안전성 분석)

  • Ha, Yejin;Jeon, Joonho
    • Journal of Institute of Convergence Technology
    • /
    • v.11 no.1
    • /
    • pp.25-28
    • /
    • 2021
  • Recently, the fire safety of road tunnels has been important issues in South Korea. However, proper fire safety regulations has not made for road tunnels. Due to geographical challenges in South Korea, road tunnels should be constructed to secure stable traffic flows. In the Guidelines for Installing and Managing Disaster Prevention Facilities of Road Tunnels (NFSC 603), main target vehicles are passenger cars. This guidelines cannot support big fires from larger vehicles such as cargo, oil trucks. In this study, fire safety for a road tunnel in port area was analyzed with fire dynamics theory under cargo truck fire scenario. Sujunsan road tunnel in Busan city was chosen as a target tunnel, which links between Busan port and highways to increase cargo shipping. The results show the limitations of present guidelines (NFSC 603) for road tunnel from large fire situations.

An Experimental Study of Critical Velocity in Sloping Tunnel Fires (경사 터널내 화재시 임계속도에 관한 실험적 연구)

  • 이성룡;김충익;유홍선;김혁순;전명배
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.49-53
    • /
    • 2004
  • In this study, reduced-scale experiments were conducted to analyze an effect of tunnel slope on critical velocity. The 1/20 scale experiments were carried out under the Froude scaling using ethanol pool fire. Square pools ranging from 2.47 to 12.30㎾ were used experiments. Critical velocity varied with one-fourth power of the heat release rate. As the slope of the tunnel increases the critical velocity comes to be fast due to the increase of the chimney effect.

Development of a Computer Program to Evaluate Smoke Volume Flow rate and Temperature for Tunnel Fires (터널 화재시 연기발생량 및 온도 예측 프로그램 개발)

  • Park, Won-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.506-510
    • /
    • 2007
  • Smoke temperature and volume flow rate in a tunnel fire are calculated. To obtain realistic results, enthalpy of smoke which composites combustion gases and entrainment air is calculated from curvefit polynomials by temperature. A user-friendly computer program for them is also developed. This program might be used for a good engineering tool in design of fire safety and mock/reduced-scale fire tests in a tunnel.

THE EXAMINATION OF ACCURACY OF FIRE-DRIVEN FLOW SIMULATION IN TUNNEL EQUIPPED WITH VENTILATION (환기가 있는 터널에서의 화재유동 해석의 정확성에 대한 고찰)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Kim, Hag-Beom;Jung, Woo-Sung
    • Journal of computational fluids engineering
    • /
    • v.14 no.3
    • /
    • pp.115-122
    • /
    • 2009
  • Numerical methods are applied to simulate the smoke behavior in a ventilated tunnel using large eddy simulation (LES) which is incorporated in FDS (Fire Dynamics Simulator) with proper combustion and radiation model. In this study, present numerical results are compared with data obtained from experiments on pool fires in a ventilated tunnel. The model tunnel is $182m(L){\times}5.4m(W){\times}2.4m(H)$. Two fire scenarios with different ventilation rates are considered with two different fire strengths. The present results are analyzed with those from LES without combustion and radiation model and from RANS ($\kappa-\epsilon$) model as well. Temperature distributions caused by fire in tunnel are compared with each other. It is found that thermal stratification and smoke back-layer can be predicted by FDS and the temperature predictions by FDS show better results than LES without combustion and radiation model. The FDS solver, however, failed to predict correct flow pattern when the high ventilation rate is considered in tunnel because of the defects in the tunnel-inlet turbulence and the near-wall turbulence.

Experimental Study on the Designed Ventilation Effect on the Smoke Movement at Rescue Station fire in Railway Tunnel (터널 내 화재발생시 구난역 내의 연기 거동에 미치는 설계된 환기 영향에 대한 실험적 연구)

  • Kim, Dong-Woon;Lee, Seong-Hyeok;Ryou, Hong-Sun;Yoon, Sung-Wook
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.163-167
    • /
    • 2008
  • In this study, the 1/35 reduced-scale model experiment were conducted to investigate designed ventilation effect on the smoke movement at rescue station fire in railway tunnel. A model tunnel with 2 mm thick, 10 m long, 0.19 m high and 0.26 m was made by using Froude number scaling law. The cross-passages installing escape door at the center were connected between incident tunnel and rescue tunnel. The n-heptane pool fires with heat release rate 698.97W were used as fire source. The fire source was located at the center and portal of incident tunnel as worst case. A operating ventilation system extracted smoke amount of 0.015 cms(cubic meters per second). The smoke temperature and CO gas concentration in cross-passage were measured to verify designed ventilation system. The result showed that, at center fire case without ventilation, smoke did not propagate to rescues station. In portal fire case, smoke spreaded to rescues station without ventilation. But smoke did not propagated to rescues station with designed ventilation.

  • PDF

Experimental and Numerical Study of Smoke Movement in Tunnel Fires (터널 화재 시 연기전파에 대한 실물실험 및 수치해석적 연구)

  • Lee Seung-Chul;Lee Seung-Ho;Kim Nam-Young
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.341-347
    • /
    • 2005
  • 본 논문은 터널에서 화재 발생 시, 시간에 따른 연기거동에 대해 실물실험과 3차원 수치해석을 수행하고 각각의 결과를 비교,검토하였다. 실물실험을 위하여 8.8 kW의 열원과 901iter/h의 연기 발생이 가능한 연기발생장치를 자체 제작하였으며, 대상터널은 길이 570m, 단면적 $64.6m^2,$ 그리고 약 $2\%$의 구배를 가지고 있다. 실험은 외풍의 영향을 줄이기 위해 터널 입,출구에 차단막을 설치하였으며 연기발생장치로부터 20m 간격의 위치에서 20초 간격으로 연기전파, 속도 그리고 온도를 측정하였다. 연기는 60초 경과 후, 연기발생장치로부터 20m 떨어진 위치에 도달하였으며 140초, 180초 및 260초 경과 후, 각각 40m, 60m 및 80m 위치에 도달하였다. 3차원 수치해석의 결과는 터널벽면을 매끈한 표면으로 처리하였을 때, $26.3\~49.5\%$정도 과대 예측하였다. 또한 터널벽면을 일정 조도를 갖는 거친 표면으로 처리한 경우는 $-2.7\~17.6\%$ 오차로 실험결과에 보다 근접하는 결과를 보였다. 따라서 터널 내 연기거동에 대한 3차원 수치해석을 수행할 때에는 벽면조도에 대한 고려가 필요하리라 판단된다.

  • PDF

Derivations of Positive Pressure Condition for Development of Foldable Safe Pathway in Railway Tunnel Fires (철도터널화재용 접이식 대피통로 개발을 위한 양압 조건 도출)

  • Kim, JiTae;Ro, Kyoungchul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.284-289
    • /
    • 2019
  • The Korea Foldable safe pathway system is an evacuation support system to get temporary evacuation route in railway tunnel and large space fires. A prevention smoke screen is unfolded in fires and it is needed to prevent heat and smoke from fire source. Therefore, ventilation system for positive pressure condition is equipped with foldable safe pathway system. Numerical analyses of temperature and pressure distribution with distance from fire source were performed considering fire scenario of new train vehicle. The smoke temperatures did not exceed $200^{\circ}C$ that distance from the fire source was more than 20 m and smoke pressure was reduced with distance from fire source. Maximum smoke pressure was 14 Pa and average pressure was 6 Pa in position of prevention smoke screen. As results, to install foldable safe pathway system, ventilation system is need to maintain 6 Pa positive pressure condition.

An Experimental Study on Smoke Movement by the External Wind in Road Tunnel Fires (도로터널 화재 시 외부 바람에 의한 연기거동 특성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Tunnel and Underground Space
    • /
    • v.24 no.4
    • /
    • pp.308-315
    • /
    • 2014
  • In this study, reduced scale experiments were carried out to evaluate the effect of external wind in a road tunnel fire. Experiments were conducted in a $1.1m{\times}0.5m{\times}50.4m$ tunnel. 4.5 litter gasoline was used as a fuel. Temperature, oxygen and carbon monoxide concentration were measured. Smoke reaching time to the tunnel exit was affected by the external wind. When a fire was fully developed, wind effect is reduced compared with the early stage of a fire. CO concentration was reached at more than 1,500 ppm.