• Title/Summary/Keyword: Tunnel Characteristics

Search Result 1,876, Processing Time 0.026 seconds

Prediction methods on tunnel-excavation induced surface settlement around adjacent building

  • Ding, Zhi;Wei, Xin-jiang;Wei, Gang
    • Geomechanics and Engineering
    • /
    • v.12 no.2
    • /
    • pp.185-195
    • /
    • 2017
  • With the rapid development of urban underground traffic, the study of soil deformation induced by subway tunnel construction and its settlement prediction are gradually of general concern in engineering circles. The law of soil displacement caused by shield tunnel construction of adjacent buildings is analyzed in this paper. The author holds that ground surface settlement based on the Gauss curve or Peck formula induced by tunnel excavation of adjacent buildings is not reasonable. Integrating existing research accomplishments, the paper proposed that surface settlement presents cork distribution curve characters, skewed distribution curve characteristics and normal distribution curve characteristics when the tunnel is respectively under buildings, within the scope of the disturbance and outside the scope of the disturbance. Calculation formulas and parameters on cork distribution curve and skewed distribution curve were put forward. The numerical simulation, experimental comparison and model test analysis show that it is reasonable for surface settlement to present cork distribution curve characters, skewed distribution curve characteristics and normal distribution curve characteristics within a certain range. The research findings can be used to make effective prediction of ground surface settlement caused by tunnel construction of adjacent buildings, and to provide theoretical guidance for the design and shield tunnelling.

CHARACTERISTICS OF SMOKE CONCENTRATION PROFILES WITH UNDERGROUND UTILITY TUNNEL FIRE

  • Kim Hong Sik;Hwang In Ju;Kim Youn-Jea
    • Journal of computational fluids engineering
    • /
    • v.10 no.1
    • /
    • pp.94-98
    • /
    • 2005
  • Accurate prediction of the fire-induced air velocity, temperature and smoke flow in underground utility tunnel becomes more important for the optimization of design and placement of heat and smoke detectors. In order to improve the safety of underground utility tunnel systems, the behaviors of fire-induced smoke flow and temperature distributions are investigated. Especially, two different cross-sectional shapes of tunnel, such as rectangular and circular types are modeled. Also, fire source is modeled as a volumetric heat source. Three-dimensional thermal-flow characteristics in an underground tunnel are solved by means of FVM using SIMPLE algorithm. The effects of shape geometry on the fire-induced flow characteristics are graphically depicted. It is desirable that heat and smoke detectors are installed on the cables and the top of the wall.

The Present State and Behavior Characteristics of Water Supply Tunnel (수로터널의 유지관리 현황 및 거동특성)

  • Jeon, Je-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.179-190
    • /
    • 2006
  • The water supply tunnel has different characteristics which play a important role in stable water supply to the public from mechanical behavior and maintenance in comparison with road md railway tunnel. In this study, the present state and characteristics of water supply tunnels controlled by K-water have been investigated. The distribution of effective stresses that takes into account the effect of seepage forces induced by internal water pressure are estimated from closed-form and numerical method. The analysis of stress-strain behavior, seepage problem and hydrojacking for ensuring safety of existing water supply tunnel against neighboring new construction has been conducted.

  • PDF

Resonance Characteristics for 2-Dimensional Circular Wind Tunnel (2차원 원형 풍동의 공진 특성)

  • Baik, Ki-Young;Lee, In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1087-1095
    • /
    • 1990
  • A finite element method is used for analyzing the resonance characteristics of circular wind tunnel. Two-dimensional circular wind tunnel with one and three slots is considered. The wind tunnel resonance characteristics are affected by the number and position of the slots of the wind tunnel. The resonant frequencies for the vertical vibration mode are higher than those for the horizontal vibration mode. The resonance frequencies increase as the open area ratio increases.

Crosswind effects on high-sided road vehicles with and without movement

  • Wang, Bin;Xu, You-Lin;Zhu, Le-Dong;Li, Yong-Le
    • Wind and Structures
    • /
    • v.18 no.2
    • /
    • pp.155-180
    • /
    • 2014
  • The safety of road vehicles on the ground in crosswind has been investigated for many years. One of the most important fundamentals in the safety analysis is aerodynamic characteristics of a vehicle in crosswind. The most common way to study the aerodynamic characteristics of a vehicle in crosswind is wind tunnel tests to measure the aerodynamic coefficients and/or pressure coefficients of the vehicle. Due to the complexity of wind tunnel test equipment and procedure, the features of flow field around the vehicle are seldom explored in a wind tunnel, particularly for the vehicle moving on the ground. As a complementary to wind tunnel tests, the numerical method using computational fluid dynamics (CFD) can be employed as an effective tool to explore the aerodynamic characteristics of as well as flow features around the vehicle. This study explores crosswind effects on a high-sided lorry on the ground with and without movement through CFD simulations together with wind tunnel tests. Firstly, the aerodynamic forces on a stationary lorry model are measured in a wind tunnel, and the results are compared with the previous measurement results. The CFD with unsteady RANS method is then employed to simulate wind flow around and wind pressures on the stationary lorry. The numerical aerodynamic forces are compared with the wind tunnel test results. Furthermore, the same CFD method is extended to investigate the moving vehicle on the ground in crosswind. The results show that the CFD results match with wind tunnel test results and the current way using aerodynamic coefficients from a stationary vehicle in crosswind is acceptable. The CFD simulation can provide more insights on flow field and pressure distribution which are difficult to be obtained by wind tunnel tests.

Characteristics of Fire-induced Thermal-Flowfields in an Underground Utility Tunnel with Ventilation (화재 발생시 환기방식에 따른 지하공동구내 열유동 특성 연구)

  • Kim, Hong-Sik;Hwang, In-Ju;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1845-1850
    • /
    • 2003
  • The underground utility tunnels are important facility as a mainstay of country because of communication developments. The communication and electrical duct banks as well as various utility lines for urban life are installed in the underground utility tunnel systems. If a fire breaks out in this life-line tunnel, the function of the city will be discontinued and the huge damages are occurred. In order to improve the safety of life-line tunnel systems and the fire detection, the behaviors of the fire-induced smoke flow and temperature distribution are investigated. In this study we assumed that the fire is occurred at the contact or connection points of cable. Numerical calculations are carried out using different velocity of ventilation in utility tunnel. The fire source is modeled as a volumetric heat source. Three-dimensional flow and thermal characteristics in the underground tunnel are solved by means of FVM (Finite Volume Method) using SIMPLE algorithm and standard ${\kappa}-{\varepsilon}$ model for Reynolds stress terms. The numerical results of the fire-induced flow characteristics in an underground utility tunnel with different velocity of ventilation are graphically prepared and discussed.

  • PDF

Macro-Modeling for Magnetic Tunnel Junction (Magnetic Tunnel Junction 의 Macro-Modeling)

  • 홍승균;송상헌;김수원
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.943-946
    • /
    • 2003
  • This paper proposes new SPICE Macro-Model of MTJ(Magnetic Tunnel Junction). This Macro-Model has five I/O terminals, reproduces MR characteristics including hysteresis and behaves correctly to time varying input signals. Furthermore, this Model can be easily modified to various MTJs with different characteristics by simply varying internal parameters.

  • PDF

A Study on Development Evaluation Modeling Internal Landscape in Tunnel Considering Human Sensitivity Engineering (감성공학을 고려한 터널 내부경관 평가 모형개발에 관한 연구)

  • Wang, Yi-Wau;Kum, Ki-Jung;Son, Seung-Neo;Yu, Jai-Sang
    • International Journal of Highway Engineering
    • /
    • v.12 no.1
    • /
    • pp.9-20
    • /
    • 2010
  • This study was intended to identify, among various characteristics of tunnel, the relationship between the design factors comprising the driver's psychological stability, easiness and the sensitivity and then to suggest the mechanism for evaluating the tunnel view, and to that end, the study attempted to evaluate the relations between the physical elements comprising the tunnel shape and the variation of driver's emotional recognition, thereby proposing the measures to create the scenic environment. As a result of LISREL modeling to identify the characteristics of emotional recognition to tunnel view, the elements affecting tunnel view appeared to be emotional image created by the combination of elements comprising the tunnel view. Such emotional image can be explained by design elements and individual characteristics, and the effect of design element appeared to be greater than individual characteristics. The relations between individual characteristics and design element appeared to be positive (+) and the relations between the "safety" and "variability" was significant. And the "safety" have had greater effect on view recognition than "variability", indicating that the drivers tend to give more importance to "safety", but also require the "variability"on the other hand.

Theoretical Study on the Characteristics of Pressure Change of High Speed Train in Tunnels (터널통과시 고속 철도 압력 변동 특성에 관한 이론적 연구)

  • Nam, Seong-Won;Kwon, Hyeok-Bin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.9
    • /
    • pp.1042-1050
    • /
    • 2004
  • Theoretical study has been conducted to clarify pressure characteristics of KTX(Korea Train eXpress) in tunnel. The severe pressure change in tunnel may give rise to the ear-discomfort for passenger and fatigue for car body. The external and internal pressure of rolling stock have been measured by using the running test with atmospheric pressure sensors and portable data acquisition system in high speed train. In this study, the tunnels from 200m to 4000m in length have been chosen for the investigation of tunnel length effects. We found that there are similar patterns of external pressure change for each critical tunnel length. The critical tunnel lengths are governed by train speed, train length and sonic velocity. And, the patterns of pressure wave in tunnel are classified into eight groups.

Path Loss Characterization in Tunnel Using Ray Launching Method at 2.6 GHz (Ray-Launching 기법을 이용한 2.6 GHz 대역의 터널 내 경로손실 특성 분석)

  • Kim, Do-Youn;Jo, Han-Shin;Yook, Jong-Gwan;Park, Han-Kyu
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.33-37
    • /
    • 2003
  • This paper presents the characteristics of large-scale fading in a tunnel environment. The Ray-Launching Method has been used to analyze the characteristics of the tunnel. For a curved tunnel, The concept of RDN (Ray Density Normalization) is introduced in order to obtain more accurate results. For our purposes, the structure of tunnel is assumed to be either a straight or curved tunnel having rectangular cross-section. A large scale fading has been presented shown in several tunnel cases.

  • PDF