휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정 (Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System)

  • 강나루;우영아;차봉수;이현철;김효진
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

Noninvasive blood glucose monitoring system based on NIR spectroscopy with a contact pressure control device

  • Kang, Na-Roo;Baek, Ju-Hyun;Woo, Young-Ah;Kim, Hyo-Jin
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.67.3-68
    • /
    • 2003
  • The purpose of this study is to improve repeatability of a non-invasive blood glucose measurement. The portable NIR system that was newly integrated by our lab includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector, which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of finger tip were recorded by using a fiber optic probe. The probe was fixed in the system and subjects put their finger on the probe head. (omitted)

  • PDF

초분광영상의 조명효과 보정 전처리기법 분석 (Analyzing Preprocessing for Correcting Lighting Effects in Hyperspectral Images)

  • 송영선
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.785-792
    • /
    • 2023
  • Because hyperspectral imaging provides detailed spectral information across a broad range of wavelengths, it can be utilized in numerous applications, including environmental monitoring, food quality inspection, medical diagnosis, material identification, art authentication, and crime scene analysis. However, hyperspectral images often contain various types of distortions due to the environmental conditions during image acquisition, which necessitates the proper removal of these distortions through a data preprocessing process. In this study, a preprocessing method was investigated to effectively correct the distortion caused by artificial light sources used in indoor hyperspectral imaging. For this purpose, a halogen-tungsten artificial light source was installed indoors, and hyperspectral images were acquired. The acquired images were then corrected for distortion using a preprocessing that does not require complex auxiliary equipment. After the corrections were made, the results were analyzed. According to the analysis, a statistical transformation technique using mean and standard deviation with reference to a reference signal was found to be the most effective in correcting distortions caused by artificial light sources.

근적외선 분광법을 이용한 돈분뇨 액비 성분분석기 개발을 위한 기초 연구 (Basic Study on the Development of Analytical Instrument for Liquid Pig Manure Component Using Near Infra-Red Spectroscopy)

  • 최동윤;곽정훈;박치호;정광화;김재환;송준익;유용희;정만순;양창범
    • 한국축산시설환경학회지
    • /
    • 제13권2호
    • /
    • pp.113-120
    • /
    • 2007
  • 본 시험은 근적외선분광법을 이용한 돈분뇨 액비의 질소, 인산, 칼리, 수분 및 유기물의 분석 가능성을 구명하고, 이를 활용한 분석기의 개발을 목적으로 수행하였으며, 그 결과는 다음과 같다. 1. 돈분뇨 액비시료는 $400{\sim}2,500nm$ 대역의 근적외선을 시료에 투과하여 측정하였으며, 동일시료에 대한 습식분석 결과, N, $P_2O_5,\;K_2O$, 수분 및 유기물 함량은 각각 1,555mg/l, 302mg/l, 240mg/l, 98.8%, 0.53%로 조사되었다. 2. 근적외선 분광광도법을 이용한 분석에서 N, $P_2O_5,\;K_2O$, 수분 및 유기물에 대한 RSQ ($r^2$, R, Coefficient of determination)는 각각 0.9190, 0.9749, 0.5046, 0.9883 및 0.9777이었고 SEC(Standard Error of Calibration)는 2.1649, 0.5019, 1.9252, 0.1180 및 0.0789였다. 3. 액비에 대한 이화학적 습식분석과 NIR 흡수스펙트럼 측정결과를 비교 분석하여 돈 분뇨 액비에 포함된 질소, 인산, 칼리, 수분 및 유기물 함량을 실시간으로 분석하고 액비 성분량을 자동 계산할 수 있는 알고리즘을 도입한 액비분석 프로그램을 작성하였다. 4. 액비 성분분석 시작기는 근적외선(NIR : Near InfraRed)을 받아들여 실시간으로 액비성분의 흡수율을 측정하는 광검출장치(NIR Spectrometer), 근적외선 Light Source로부터 나오는 빛을 반사시키는 반사경, 액비성분 분석용 시료를 넣어 측정하는 Cell Mount, $400{\sim}2,500nm$ 대역의 가시광선-근적외선을 방출하는 Tungsten halogen lamp, NIR Spectrometer와 Tungsten halogen lamp로 전압을 입력시켜 주는 Power Supply Module 및 전체를 Black Anodizing한 외형으로 구성되었다. 5. 실험결과, 칼리를 제외한 액비내 모든 성분이 광을 흡수하는 강도는 성분의 농도에 비례하였으며 원시 스펙트럼의 중첩 제거 및 빛의 산란보정을 통해 액비의 질소, 인산성분, 수분 및 유기물 함량을 측정하는데 효과적으로 이용할 수 있을 것으로 사료되며, 분광분석법을 이용한 액비성분 분석기 개발이 완료되면 현장에서 신속하고 정확한 분석이 가능할 것으로 판단된다.

  • PDF

임상가가 알아두면 유용한 LED 광중합기의 특성과 세대별 분류 (Characteristic of LED light curing unit and classification by generation for clinicians)

  • 심영보;최안나;박정길
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.245-251
    • /
    • 2017
  • 1960년대 광중합 레진이 소개된 이후 현재의 수복학에서 광중합은 중요한 과정으로 고려되고 있다. 광중합을 위한 다양한 중합기들이 소개되어서 발전하면서 사용되어져 왔다. Quartz-tungsten-halogen (QTH) 광중합기는 1990년도까지 널리 사용되었으며 2000년 들어 LED 광중합기가 널리 사용되고 있다. 1세대 LED 광중합기는 여러 개의 LED가 출력을 내는 광중합기로 QTH 광중합기에 비해 높은 출력을 내짐 못했다. 2세대 LED 광중합기는 하나의 LED로도 충분한 출력을 낼 수 있게 되었으며, camphoroquinone (CQ) 이외에 부가 중합개시제를 고려하여 3세대 polywave 중합기가 시장에 출시되었다. 현재는 LED에서 방출하는 빛이 계속 switching되는 4세대 광중합기가 개발되어 출시되었다. 이러한 LED 광중합기의 발전에 따라 사용하는 광중합기의 대부분이 LED 광중합기로 자리잡고 있다. LED 광중합기의 사용의 증가에 따라 임상가들은 광중합기의 특성을 이해하고 있어야 한다. 본 리뷰 논문의 목적은 LED 광중합기에 대한 세대별 분류와 특징에 대한 정보를 주기 위함이다.

램프 가열 방식 LPCVD 장비의 설계 및 제작 (Design and Implementation of Lamp-Heated LPCVD System)

  • 하용민;김태성;김충기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.299-303
    • /
    • 1991
  • A lamp heated LPCVD equipment has been made. Wafer is heated by an array of fifteen tungsten halogen lamps above the front side of a wafer and pyrometer views the back side of the wafer through $CaF_2$ window. Reactor which consisits of a quartz window and a water cooled-stainless steel plate can be evacuated to $5{\times}10^{-3}$ torr with a rotary vane pump. By pyrolysis of $SiH_4$ at about $600^{\circ}C$, polysilicon has been formed on the silicon dioxide film. The measured results show that thickness nonuniformity is 15% and temperature nonuniformity is 1.1%. Because activation energy of pyrolysis of $SiH_4$ is very high, about 1.8eV, small temperature variation will induce large thickness nonuniformity. The main cause of temperature nonuniformity is unsymmetry of lamp power and an unbalanced cooling structure. Charls & Evans' SIMS result shows that the oxygen content in the deposited polysilicon is comparable to that of silicon substrate but carbon content is ten times higher.

  • PDF

Cahn Balance를 이용한 급속 가열방식의 석탄가스화 장치 소개 (An Introduction of an Apparatus for Rapid Heating Coal Gasification)

  • 이중기;이성호;임태훈
    • 공업화학
    • /
    • 제2권4호
    • /
    • pp.393-398
    • /
    • 1991
  • 실제 실험 시간에 따른 시료의 무게변화와 생성가스의 조성 측정을 동시에 진행할 수 있는 실험실 규모의 장치를 칸 발란스를 이용하여 제작하였다. 급속 가열이 가능하도록 텅스텐 할로겐 등을 이용한 복사가열 방식을 채택하였고 시료 접시는 복사열을 충분히 흡수하도록 흑연을 사용하였다. 석탄가스화 실험조건에서 이 흑연이 반응기체와 반응하는 것을 막기위하여 실리콘나이트로 코팅하였고, 시료접시 바로 밑에 위치한 열전쌍에도 같은 방식으로 제작된 흑연 모자를 씌워 복사열 흡수능력이 서로 다른 흑연(시료접시)과 금속체(열전쌍) 사이에서 생길 수 있는 온도 측정의 오차를 최소화 하도록 하였다. 이 장치를 사용한 결과 상온에서 섭씨 800도까지 3 분 이내에 온도상승이 가능하였으며 시료 접시의 무게변화없이 실험중 석탄 시료의 무게 변화와 가스조성을 동시에 측정할 수 있었다.

  • PDF

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

하이퍼 스펙트랄 반사광 및 형광 산란을 이용한 사과 품질 측정 (Apple Quality Measurement Using Hyperspectral Reflectance and Fluorescence Scattering)

  • 노현권
    • Journal of Biosystems Engineering
    • /
    • 제34권1호
    • /
    • pp.37-43
    • /
    • 2009
  • Hyperspectral reflectance and fluorescence scattering have been researched recently for measuring fruit post-harvest quality and condition. And they are promising for nondestructive detection of fruit quality. The objective of this research was to develop a model, which measure the quality of apple by using hyperspectral reflectance and fluorescence. A violet laser (408 nm) and a quartz tungsten halogen light were used as light sources for generating laser induced fluorescence and reflectance scattering in apples, respectively. The laser induced fluorescence and reflectance of 'Golden Delicious' apples were measured by using a hyperspectral imaging system. Fruit firmness, soluble solids and acid content were measured using standard destructive methods. Principal component analyses were performed to extract critical information from both hyperspectral reflectance and fluorescence data and this information was then related to fruit quality indexes. The fluorescence models had poorer predictions of the three quality indexes than the reflectance models. However, the prediction models of integrating fluorescence and reflectance performed consistently better than the individual models of either reflectance or fluorescence. The correlation coefficient for fruit firmness, soluble solid content, and tillable acidity from the integrated model was 0.86, 0.75, and 0.66 respectively. Also the standard errors were 6.97 N, 1.05%, and 0.07% respectively.

SLIP 현상 및 공정소모 POWER를 최소화하기 위한 RTA 제작 (RTA Development to Minimize SLIP and Process Power Consumption)

  • 권경섭;장현용;황호정
    • 대한전자공학회논문지
    • /
    • 제26권7호
    • /
    • pp.58-72
    • /
    • 1989
  • 본 연구에서는 텅스텐 할로겐 램프를 사용한 RTA(or RTP) 장치를 제작하여 웨이퍼 가장자리와 내부사이의 서로 다른 반사계수를 갖는 반사판을 사용하여 $1300^{\circ}C$에서 최소 2개까지 슬립 (${\2"}$ wafer) 발생억제 효과를 얻을 수 있었다. 뿐만 아니라 웨이퍼 주위에 흑연환을 씌워 경계에서 잃는 온도 보상효과를 주어 슬립 생성을 억제시킬 수 있었다. 또한 소모전력감소 및 슬립현장을 동시에 줄이기 위한 또 다른 방법으로 Two-channel heating을 제시하였다.

  • PDF