• Title/Summary/Keyword: Tumor therapy

Search Result 2,203, Processing Time 0.035 seconds

The Results of Intraoperative Radiotherapy for Stomach Cancer (위암의 수술 중 방사선치료의 결과)

  • Choi, Ji-Hoon;Kang, Min-Kyu;Kim, Myung-Se;Kim, Sung-Kyu;Yun, Sang-Mo;Kim, Sung-Hoon
    • Radiation Oncology Journal
    • /
    • v.28 no.2
    • /
    • pp.79-84
    • /
    • 2010
  • Purpose: We retrospectively analyzed the long-term results of radical surgery and intraoperative radiation therapy (IORT) in patients with stomach cancer. Materials and Methods: From 1988 to 1994, 51 patients were treated with curative surgery and IORT. Postoperative external beam radiotherapy (EBRT) was administered to 30 patients, while adjuvant chemotherapy was administered to 35 patients. A dose of 15 Gy was irradiated with a 9 MeV electron beam as the IORT and a median dose of EBRT was 43.2 Gy (range, 7.2 to 45 Gy). The follow-up period ranged from 1~254 months, with a median follow-up period of 64 months. Results: The median age of all the patients was 58 years (range, 30 to 71 years). The distribution of pathologic stage (American Joint Committee on Cancer [AJCC] 2002 tumor-note-metastasis [TNM]) was as follows: 13 stage I (25.5%), 10 stage II (19.6%), 25 stage III (49.0%), and 3 stage IV (5.9%). Distant metastases occurred in 11 patients (10 in the peritoneum and 1 in bone), including one patient with concurrent local recurrence (anastomosis site). The 5-year locoregional control, disease free survival and overall survival rates were 94.7%, 66.5%, and 51.7%, respectively. For the multivariate analysis, age, TNM stage, and EBRT were significant prognostic factors for overall survival, and only TNM stage for disease free survival. Conclusion: We could have achieved a high loco-regional control rate in patients with locally advanced stomach cancer by adding IORT to radical surgery. However, the benefit of IORT on survival remains to be elucidated.

Clinical characteristics and courses of congenital muscular torticollis (선천성 근육성 사경의 임상적 특징과 경과)

  • Choi, Kyong Eun;Lee, Hee Chul;Youn, So Young;Chun, Jung Mi;Shin, Son Moon;Han, Byung Hee;Lee, Yong Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.11
    • /
    • pp.1273-1278
    • /
    • 2009
  • Purpose:Congenital muscular torticollis (CMT), a common musculoskeletal disorder in infants, is characterized by the rotation and flexion deformity of the neck caused by sternocleidomastoid muscle shortening. We investigated the clinical courses and perinatal risk factors of CMT. Methods:Less than 6-month-old patients (98; M:F = 60:38) diagnosed with CMT between February 2007 and August 2008 were classified into 2 clinical subgroups, namely, SMT (sternocleidomastoid tumor) and POST (postural torticollis). All the patients were physically and neurologically examined prospectively and their cervical X-rays and ultrasonographies were obtained. Their medical histories about perinatal problems were recorded. Of the 98 patients, 45 with normal range of motion were taught passive physical exercises and 43 were referred to the Department of Rehabilitation for undergoing manual stretching therapy. Results:The mean age at initial assessment was 2.2 months (SMT: $1.4{\pm}1.0$, POST: $2.7{\pm}1.6$). SMT presented earlier than POST. All ophthalmologic examinations and cervical X-rays were normal. SMT was associated with higher incidence of caput succedaneum and cephalhematoma. POST was highly associated with plagiocephaly. Mean duration of rehabilitative physical therapy was 3.7 months (SMT: $4.6{\pm}2.5$, POST: $2.6{\pm}1.9$). POST resolved earlier than SMT. Of the 88 patients with follow-up, 87 had total resolution and only 1 had residual torticollis. Conclusion:All the patients received early treatment with passive stretching exercises. CMT was associated with perinatal problems and had various risk factors such as obstetrical problems.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF

Comparison of $Na^+/I^-$ Symporter Expression Rate in Malignant and Benign Thyroid Diseases: Immunohistochemical Study (악성 및 양성 갑상선 질환의 조직에서 면역조직학적 검사법에 의한 $Na^+/I^-$ symporter의 발현율 비교)

  • Kang, Do-Young;Jeong, Young-Jin;Lee, Kyung-Eun;Park, Heon-Soo;Yoo, Young-Hyun;Roh, Mee-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2006
  • Purpose: Previous studies have not showed consistent results for the level of expression of sodium/iodide symporter (NIS) in thyroid diseases, especially malignant tumor. We undertook this study to evaluate the distribution of NIS expression in malignant thyroid diseases and compare with that in benign thyroid disease. Materials and Methods: Total patients were 119 cases (Men 15, $48{\pm}13$ yrs). Total number of samples were 205 pieces. In malignant thyroid disease, there were 153 samples: 90 in papillary carcinoma, 4 in follicular carcinoma, 2 in medullary carcinoma and 57 in metastatic lymph node. In benign thyroid disease, there were 52 samples: 36 in goiter/cyst, 11 in thyroiditis and 5 in follicular adenoma. Using immunohistochemical methods, we probed 205 samples with monoclonal anti-NIS Ab. Grading of staining was stored as 0 (negative or absent), 1 (weakly positive), 2 (moderately positive) or 3 (strongly positive). Expression rate (ER) of NIS positivity in individual disease entity was expressed as percentage of total number divided by number in 2 plus 3 grade. Results: ERs of malignant thyroid diseases were 63% in papillary carcinoma, 81% in metastatic lymph node, 71% in follicular carcinoma and 100% in medullary carcinoma. ERs of benign thyroid disease were 53% in goiter/cyst, 64% in thyroiditis and 40% in follicular adenoma. ER of malignant thyroid diseases was higher than benign thyroid diseases (71% vs 54%). Grading of NIS expression in papillary carcinoma or goiter/cyst was heterogeneously distributed in considerable cases. Normal tissue also showed heterogeneous distribution of NIS expression, which was not correlated with that of primary lesion. Conclusion: In papillary thyroid carcinoma, distribution of NIS expression was heterogeneous and increased, and not different compared with that of benign thyroid disease.

Evaluation of Xerostomia Following 3 Dimensional Conformal Radiotherapy for Nasopharyngeal Cancer Patients (3차원 입체조형 방사선치료를 시행받은 코인두암 환자에서의 구강건조증 분석)

  • Park Young-Je;Park Won;Ju Sang-Gyu;Nam Hee-Rim;Oh Dong-Ryul;Park Hee-Chul;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purose: This study is to evaluate the xerostomia following 3-dimensional conformal radiation therapy (3D CRT) in nasopharynx cancer patients using the xerostomia questionnaire score (XQS). Materials and Methods: Questionnaire study was done on 51 patients with nasopharynx cancer who received 3D CRT from Dec. 2000 to Aug. 2005. 3D CRT technique is based on 'serial shrinking field' concept by 3 times of computed tomography (CT) simulation. Total target dose to the primary tumor was 72 Gy with 1.8 Gy daily fractions. Xerostomia was assessed with 4-questions XQS, and the associations between XQS and time elapsed after RT, age, sex, stage, concurrent chemotherapy, and parotid dose were analyzed. Results: Concurrent chemotherapy was given to 40 patients and RT alone was given to 11 patients. The median time elapsed after 3D CRT was 20 ($1{\sim}58$) months and the mean XQS of all 51 patients was $8.4{\pm}1.9\;(6{\sim}14)$. XQS continuously and significantly decreased over time after 3D CRT ($X^2$=-0.484, p<0.05). There was no significant difference in XQS according to sex, age, and stag. However, XQS of concurrent chemotherapy patients was significantly higher than RT alone patients (P=0.001). XQS of patients receiving total mean parotid dose ${\ge}35 Gy$ was significantly higher than <35 Gy (p=0.05). Decreasing tendency of XQS over time after 3D CRT was observed. Concurrent chemotherapy and total mean parotid dose ${\ge}35 Gy$ were suggested to adversely affect radiation-induced xerostomia.

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Postoperative Adjuvant MVP Chemotherapy and Radiotherapy for Non-Small Cell Lung Cancer (비소세포성폐암의 수술후 MVP복합화학요법과 방사선병용치료 결과)

  • Kim, Jong-Hoon;Choi, Eun-Kyung;Chang, Hyesook;Kim, Sang-Wee;Suh, Chul-won;Lee, Kyoo-Hyung;Lee, Jung, Shin;Kim, Sang-Hee;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Park, Seung-Il;Sohn, Kwang-Hyun
    • Radiation Oncology Journal
    • /
    • v.13 no.2
    • /
    • pp.149-156
    • /
    • 1995
  • Purpose : Since February 1991 a Prospective study for non-small cell lung cancer patients who underwent radical resection and had a risk factor of positive resection margin or regional lymph node metastasis has been conducted to evaluate the effect of MVP chemotherapy and radiotherapy on the pattern of failure, disease free and overall survival. and tolerance of combined treatment. Materials and Methods: Twenty nine patients were registered to this study until Sep. 1993; of these 26 received planned therapy Within 3 weeks after radical resection, two cycles of MVP(Mitomycin C $6mg/m^2,$ Vinblastin $6mg/m^2,$ Cisplatin $60mg/m^2$) chemotherapy was given with 4 weeks intervals. Radiotherapy (5040cGy tumor bed dose and 900cGy boost to high risk area) was started 3 to 4 weeks after chemotherapy. Results: One and two year overall survival rates were $76.5\%\;and\;58.6\%$ respectively. Locoregional failure developed in 6 patients$(23.1\%)$ and distant failure in 9 patients$(34.6\%)$ Number of involved lymph nodes, resection margin positivity showed some correlation with failure pattern but T-stage and N-stage showed no statistical significance. The group of patients who received chemotherapy within 2 weeks postoperatively and radiotherapy within 70 days showed lower incidence of distant metastasis. Postoperative combined therapy were well tolerated without definite increase of complication rate, and compliance rate in this study was $90\%$. Conclusion: 1) MVP chemotherapy showed no effect on locoregional recurrence, but appeared to decrease the distant metastasis rate and 2) combined treatments were well tolerated in all patients. 3) The group of patients who received chemotherapy within 2 weeks postoperatively and radiotherapy within 70days showed lower incidence of distant metastasis. 4) Addition of chemotherapy to radiotherapy failed to increase the overall or disease free survival.

  • PDF

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF