• Title/Summary/Keyword: Tubular structures

Search Result 374, Processing Time 0.024 seconds

Buckling resistance of axially loaded square concrete-filled double steel tubular columns

  • Ci, Junchang;Ahmed, Mizan;Tran, Viet-Linh;Jia, Hong;Chen, Shicai;Nguyen, Tan N.
    • Steel and Composite Structures
    • /
    • v.43 no.6
    • /
    • pp.689-706
    • /
    • 2022
  • Thin-walled square concrete-filled double steel tubular (CFDST) columns composed of the inner circular tube filled with concrete can be used to carry the large axial loads or strengthen existing CFST columns in composite constructions. This paper reports an experimental program carried out on short square CFDST columns loaded concentrically. The influences of important column parameters on the post-buckling performance of such columns are investigated. Test results exhibit that the inner circular tube significantly improves the ultimate loads and the ductility of such columns compared to conventional concrete-filled steel tubular (CFST) and double-skin CFST (DCFST) columns with an inner void. A mathematical model developed is used to simulate the ultimate strengths and load-strain curves of such columns loaded axially. Furthermore, the ultimate strengths of such columns are predicted using existing codified design models for conventional CFST columns as well as the formulas proposed by previous researchers and compared against a large database comprising 500 CFDST columns. Lastly, an accurate artificial neural network model is developed for the practical applications of such columns under axial loading.

Fabrication of micro carbon structures using laser-induced chemical vapor deposition and Raman spectroscopic analysis (레이저 국소증착에 의한 탄소 미세 구조물 제조 및 분광분석)

  • ;;J. Senthil Selvan
    • Laser Solutions
    • /
    • v.5 no.2
    • /
    • pp.17-22
    • /
    • 2002
  • Characteristics of micro carbon structures fabricated with laser-induced chemical vapor deposition (LCVD) are investigated. An argon ion laser (λ=514.5nm) and ethylene gas were utilized as the energy source and precursor, respectively. The laser beam was focused onto a graphite substrate to produce carbon deposit through thermal decomposition of the precursor. Average growth rate of a carbon rod increased for increasing laser power and pressure. Micro carbon rods with good surface quality were obtained at near the threshold condition. Micro carbon rods with aspect ratio of about 100 and micro tubular structures were fabricated to demonstrate the possible application of this method to the fabrication of three-dimensional microstructures. Laser Raman spectroscopic analysis of the micro carbon structures revealed that the carbon rods are consisting of amorphous carbon.

  • PDF

A Study on the Strength and Failure Mode of Co-cured Composite Joints (동시경화법으로 제조된 복합재료 조인트의 강도 및 파괴모드 연구)

  • Choi, Jin-Ho;Lee, Dae-Gil
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.3
    • /
    • pp.385-392
    • /
    • 1997
  • The joint design and manufacture of the composite structure have become an important research area because the structural efficiency of the composite structure is often determined by its joint not by its basic structure. The co-cured joint is an efficient joint technique because both curing and jointing for composite structures are achieved simultaneously. In this paper, the torque capacities of the co-cured tubular lap joint with and without knurling of the pyamid type were experimentally measure. From the experimental resuts, it was found that the excess resin played a role as an adhesive in the co-cured tubular lap joint whose steel adherends were not knurled. Also, it was found that the torque capacity of the co-cured joint was increased as the knurling size of the pyramid type on the surface of the steel adherend was increased.

Recycled aggregate concrete filled steel SHS beam-columns subjected to cyclic loading

  • Yang, You-Fu;Zhu, Lin-Tao
    • Steel and Composite Structures
    • /
    • v.9 no.1
    • /
    • pp.19-38
    • /
    • 2009
  • The present paper provides test data to evaluate the seismic performance of recycled aggregate concrete (RAC) filled steel square hollow section (SHS) beam-columns. Fifteen specimens, including 12 RAC filled steel tubular (RACFST) columns and 3 reference conventional concrete filled steel tubular (CFST) columns, were tested under reversed cyclic flexural loading while subjected to constant axially compressive load. The test parameters include: (1) axial load level (n), from 0.05 to 0.47; and (2) recycled coarse aggregate replacement ratio (r), from 0 to 50%. It was found that, generally, the seismic performance of RACFST columns was similar to that of the reference conventional CFST columns, and RACFST columns exhibited high levels of bearing capacity and ductility. Comparisons are made with predicted RACFST beam-column bearing capacities and flexural stiffness using current design codes. A theoretical model for conventional CFST beam-columns is employed in this paper for square RACFST beam-columns. The predicted load versus deformation hysteretic curves are found to exhibit satisfactory agreement with test results.

Effects of tendon damage on static and dynamic behavior of CFTA girder

  • Vu, Thuy Dung;Lee, Sang Yoon;Chaudhary, Sandeep;Kim, Dookie
    • Steel and Composite Structures
    • /
    • v.15 no.5
    • /
    • pp.567-583
    • /
    • 2013
  • Experimental studies and finite element analyses have been carried out to establish the effect of tendon damage on the structural behavior of concrete filled tubular tied arch girder (CFTA girder). The damage of tendon is considered in different stages by varying the number of damaged cables in the tendon. Static and dynamic structural parameters are observed at each stage. The results obtained from the experiments and numerical studies have been compared to validate the studies. The tendons whose damage can significantly affect the stiffness of the CFTA girder are identified by performing the sensitivity analysis. The locations in the girder which are sensitive to the tendon damage are also identified.

Composite action of notched circular CFT stub columns under axial compression

  • Ding, Fa-xing;Wen, Bing;Liu, Xue-mei;Wang, Hai-bo
    • Steel and Composite Structures
    • /
    • v.24 no.3
    • /
    • pp.309-322
    • /
    • 2017
  • This paper conducted both numerical and theoretical studies to investigate the composite action of notched circular concrete-filled steel tubular (CFT) stub columns under axial compression and established a theoretical method to predict their ultimate bearing capacity. 3D finite element (FE) analysis was conducted to simulate the composite action and the results were in good agreement with experimental results on circular CFT stub columns with differently oriented notches in steel tubes. Parametric study was conducted to understand the effects of different parameters on the mechanical behavior of circular CFT stub columns and also the composite action between the steel tube and the core concrete. Based on the results, a theoretical formula was proposed to calculate the ultimate bearing capacity of notched CFT stub columns under compression with consideration of the composite action between the steel tube and the core concrete.

Wind-induced fatigue loading of tubular steel lighting columns

  • Robertson, A.P.;Hoxey, R.P.;Short, J.L.;Burgess, L.R.;Smith, B.W.;Ko, R.H.Y.
    • Wind and Structures
    • /
    • v.4 no.2
    • /
    • pp.163-176
    • /
    • 2001
  • Two 12 m high tubular steel lighting columns have been instrumented to determine the wind-induced fatigue loading experienced by such columns. Each column supported a single luminaire mounted on a 0.5 m long bracket. One column was planted in soil, and the other bolted through a welded baseplate to a substantial concrete base. The columns were strain gauged just above the shoulder weld which connected the main shaft to the larger base tube. Forced vibration tests were undertaken to determine the natural frequencies and damping of the columns. Extensive recordings were made of response to winds with speeds from 4 m/s to 17 m/s. Selected records were analysed to obtain stress cycle counts and fatigue lives. Mean drag coefficients were also derived from the strain data to investigate experimentally the effect of Reynolds Number.

Study on rectangular concrete-filled steel tubes with unequal wall thickness

  • Zhang, Yang;Yu, Chen-Jiang;Fu, Guang-Yuan;Chen, Bing;Zhao, She-Xu;Li, Si-Ping
    • Steel and Composite Structures
    • /
    • v.22 no.5
    • /
    • pp.1073-1084
    • /
    • 2016
  • Rectangular concrete-filled steel tubular columns with unequal wall thickness were investigated in the paper. The physical centroid, the centroidal principal axes of inertia, and the section core were given. The generalized bending formula and the generalized eccentric compression formula were deduced, and the equation of the neutral axis was also provided. The two rectangular concrete-filled steel tubular stub specimens subjected to the compression load on the physical centroid and the geometric centroid respectively were tested to verify the theoretical formulas.

An Analytic study on the bond of the contact surface in CFT tubular column (중심축하중을 받는 CFT 합성기둥의 접촉면 부착에 관한 해석적 연구)

  • Ye, Sang-Min;Lee, Soo-Young;Kim, Yun-Tae;Park, Seoug-Moo
    • Proceeding of KASS Symposium
    • /
    • 2005.05a
    • /
    • pp.205-212
    • /
    • 2005
  • In order for utilization of the concrete filled tubular, It Is necessary to scrutinize interfacial characteristics between heterogeneous materials, and be performed to various analytical studies on the composite structure. In this paper, this analytic study is carried on using ABAQUS Package/ Version 5.8-1, and the variables aye the relations between the coefficient of friction and the contact pressure for analyzing the behavior on the contact surface, through modifying the analytic methods and improving some problems. It is used to subdivided analytical methods in this research which categorize into four regions and can obtain closer effect for the bond behavior. Four categories compose of the chemical bond and mechanical bond legions replaced the full-interaction before yielding, and the pure friction and moving-down regions after yielding.

  • PDF

Moment-curvature relationships to estimate deflections and second-order moments in wind-loaded RC chimneys and towers

  • Menon, Devdas
    • Wind and Structures
    • /
    • v.1 no.3
    • /
    • pp.255-269
    • /
    • 1998
  • Second-order moments of considerable magnitude arise in tall and slender RC chimneys and towers subject to along-wind loading, on account of eccentricities in the distributed self-weight of the tower in the deflected profile. An accurate solution to this problem of geometric nonlinearity is rendered difficult by the uncertainties in estimating the flexural rigidity of the tower, due to variable cracking of concrete and the 'tension stiffening' effect. This paper presents a rigorous procedure for estimating deflections and second-order moments in wind-loaded RC tubular towers. The procedure is essentially based on a generalised formulation of moment-curvature relationships for RC tubular towers, derived from the experimental and theoretical studies reported by Schlaich et al. 1979 and Menon 1994 respectively. The paper also demonstrates the application of the proposed procedure, and highlights those conditions wherein second-order moments become too significant to be overlooked in design.