• 제목/요약/키워드: Tube-by-tube method

검색결과 1,977건 처리시간 0.033초

플라즈마 살균 효과 향상을 위한 공전형 전원 시스템 (Resonance Inverter Power System for Sterilization Effective Improvement of Plasma)

  • 김주용;문상필;정장근;이현우;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.397-401
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM) voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with 6.5[㎑], 1.8[㎾] inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

The Effect of Welding Method on the Electrochemical Behavior of Austenitic Stainless Steel Sheet

  • Kim, Young-Hune;Kim, Kyoo-Young
    • Corrosion Science and Technology
    • /
    • 제9권3호
    • /
    • pp.122-128
    • /
    • 2010
  • The corrosion of the flexible tube in the automobile exhaust system is caused by the ambient water and chloride ions. Since welding is one of the key processes for the flexible tube manufacturing, it is required to select a proper welding method to prevent the flexible tube corrosion and to increase its lifetime. There are many studies about the efficiency of the welding method, but no systematic study is performed for the effect of welding method on the corrosion property of the austenitic stainless weldment. The aim of the present study is to provide information on the effect of two different welding methods of TIGW (tungsten inert gas welding) and PAW (plasma arc welding) on the corrosion property of austenitic stainless steel weldment. Materials used in this study were two types of the commercial austenitic stainless steel, STS321 and XM15J1, which were used for flexible tube material for the automotive exhaust system. Microstructure was observed by using optical microscopy (OM) and scanning electron microscopy (SEM). To evaluate the corrosion behavior, potentiodynamic and potentiostatic tests were performed. The chemical state of the passive film was analyzed in terms of XPS depth profile. Metallurgical analysis show that the ferrite content in fusion zone of both STS321 and XM15J1 is higher when welded by PAW than by TIGW. The potentiodynamic and potentiostatic test results show that both STS321 and XM15J1 have higher transpassive potential and lower passive current density when welded by PAW than by TIGW. XPS analysis indicates that the stable $Cr_2O_3$ layer at the outermost layer of the passive film is formed when welded by PAW. The result recommends that PAW is more desirable than TIGW to secure corrosion resistance of the flex tube which is usually made of austenitic stainless steel.

CO2 가스쿨러용 콤팩트열교환기 개발에 관한 연구(2) - 열유량과 압력강하에 관한 실험 및 예측 - (Experimental Study on Compact type CO2 Gas Cooler(2) - Experiments and Predictions on Heat Flowrate and Pressure Drop -)

  • 오후규;손창효
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.259-266
    • /
    • 2010
  • 다중관식 헬리컬 코일형 가스냉각기내 $CO_2$의 열유량과 압력강하는 LMTD 방식을 이용하여 예측하였고 그 결과를 실험값과 비교하였다. $CO_2$와 냉각수의 유량은 각각 0.06~0.075 kg/s이고, 가스냉각기의 냉각압력은 8~10 MPa이다. 초임계 $CO_2$의 냉각시의 열유량과 압력강하는 LMTD 방식을 이용하여 예측하였고, 이때 냉매측 열전달과 압력강하식은 각각 Gnielinski와 Dittus-Boelter 식을 사용하였다. LMTD법으로 예측한 값과 실험값을 비교한 결과, $CO_2$의 열유량과 압력강하는 상대적으로 좋은 일치를 보였다.

재생기가 포함된 원관내 왕복유동에 의한 열전달 특성 (Heat transfer characteristics by an oscillating flow in a tube with a regenerator)

  • 이건태;강병하;이재헌
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.428-439
    • /
    • 1998
  • Fluid flow and heat transfer have been numerically investigated for an oscillating flow in a tube with a regenerator. The regenerator is placed between hot and cold spaces which are heated and cooled at uniform temperature. An oscillating flow is generated by the piston motion at both ends of a tube. The time dependent, two-dimensional Navier-Stokes equations and energy equation are solved by using the finite-volume and moving grid method. The regenerator is adopted as Brinkmann-Forchheimer extended Darcy model. Numerical results are obtained for the flow and temperature fields, and described the effects of the oscillating frequency and amplitude ratio by the piston motion as well as the aspect ratio. The numerical results obtained indicate that the heat transfer between the tube wall and oscillating flow is increased as the oscillating frequency, amplitude ratio and the aspect ratio are increased.

초음파 에너지로 제조한 유화연료의 관로 흐름 특성에 관한 연구 (A Study on the Flow Characteristics of Emulsified Fuel by the Ultrasonic Energy in Tube)

  • 고경한;이승진;이병오;류정인
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1248-1256
    • /
    • 2005
  • This study was undertaken to investigate the flow characteristics of emulsified fuel with the ultrasonic energy-adding system by using the chaotic method. Efffcts of water contents within emulsified fuel, flow rate and tube length with 5m in diameter from an emulsified chamber has been discussed on the strange attractor and power spectral density function. Five probe sensors were set up from 0.5 to 2.5m by length in 0.5m increments in the tube. In particular, the chaotic features of this system have been practically characterized in terms of chaotic statistics such as the power spectral density function and phase space portraits by resorting to the somewhat noble deterministic chaos theory. In the tube, the dominant frequency increased with increasing water contents and flow rate, but decreased a little with an increase in the length from the emulsified chamber.

유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교 (Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry)

  • 박태석;한준희;조승연;이은임;조규원;권대철
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

스트레인 게이지를 이용한 선박용 추진 축계의 베어링 반력 측정에 관한 연구 (A Study on the Measurement and Analysis of Bearing Reaction Forces of Marine Propulsion Shafting System using Strain-Gauge)

  • 김철우;이용진;조권회;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.33-41
    • /
    • 2008
  • Bearing damages by shaft misalignment have frequently been happened in marine ships. Specially. after stern tube bearing damage and failure for large crude oil carriers have been reported several times. However. the bearing reaction of the after stern tube bearing cannot be measured by jack-up test due to the hull structure condition. Therefore, when the jack-up test is used for the bearing reaction measurements, the bearing reaction for the after stern tube bearing obtained from the theoretical calculation method have to be used. In this paper, the shaft alignment on the large oil crude carrier is theoretically calculated and the differences between the calculated and actual installed bearing reaction values are compared. The bearing reactions for forward stern tube bearing and intermediate bearing are calculated by the simple formula using the strain gauge bending moments obtained from the measurements. Their reliability is confirmed by comparing the bearing reactions from jack-up test and the bearing reaction for after stern tube bearing is calculated by the same test. Also, the bearing reactions on the after stern tube bearing, forward stern tube bearing and intermediate shaft bearing under all operating conditions are calculated by using the bending moments obtained from the measurements and it is confirmed that the differences of the bearing reaction for all operating conditions are caused from hull deflection. The results of this study should prove useful for the future projects of the alignment calculation including the hull deflection effectiveness.

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF

포신 마모 예측의 정확도 향상을 위한 적합 근사식 유도(I) (Derivation of Fitting Approximate Formula to Enhance the Accuracy of Cannon Tube Erosion Rate)

  • 정동윤;오명호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.80-87
    • /
    • 2002
  • We predict the unknown cannon tube erosion rate by using observed values of the standard cannon, 155mm Howitzer Ml85. We know the standard cannon's ten erosion observation values each 400 rounds. An approximate formula fitting the erosion values of the standard cannon has been derived. Numerical simulation applying this formula to the Rauf Imam's erosion equations is presented.

  • PDF

Characterization of Nano-Tube Fibers Formed by Self-propagating High Temperature Synthesis

  • Choi, Y.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2003년도 international symposium on advanced powder metallurgy
    • /
    • pp.95-96
    • /
    • 2003
  • Titanium carbide nano-tube and fibers were synthesized by self-propagating high temperature synthesis (SHS) method. The average diameters of the nano-tubes and nano-fibers are about 100 and 20 nm in diameter, respectively. the non-stoichiometric numbers of the titanium carbide determined by neutron diffractometry were 0.87 and 0.94.

  • PDF