• 제목/요약/키워드: Tube-by-Tube Method

검색결과 1,977건 처리시간 0.031초

Effect of tube area on the behavior of concrete filled tubular columns

  • Gupta, P.K.;Verma, V.K.;Khaudhair, Ziyad A.;Singh, Heaven
    • Computers and Concrete
    • /
    • 제15권2호
    • /
    • pp.141-166
    • /
    • 2015
  • In the present study, a Finite Element Model has been developed and used to study the effect of diameter to wall thickness ratio (D/t) of steel tube filled with concrete under axial loading on its behavior and load carrying capacity. The model is verified by comparing its findings with available experimental results. Influence of thickness and area of steel tube on strength, ductility, confinement and failure mode shapes has been studied. Strength enhancement factors, load factor, confinement contribution, percentage of steel and ductility index are defined and introduced for the assessment. A parametric study by varying length and thickness of tube has been carried out. Diameter of tube kept constant and equals to 140 mm while thickness has been varied between 1 mm and 6 mm. Equations were developed to find out the ultimate load and confined concrete strength of concrete. Variation of lateral confining pressure along the length of concrete cylinder was obtained and found that it varies along the length. The increase in length of tubes has a minimal effect on strength of tube but it affects the failure mode shapes. The findings indicate that optimum use of materials can be achieved by deciding the thickness of steel tube. A better ductility index can be obtained with the use of higher thickness of tube.

핀-관 열교환기에서의 접촉열저항 평가에 관한 연구 (A Study on the Thermal Contact Resistance Evaluation for Fin-Tube Heat Exchangers)

  • 정진;김창녕;윤백;길성호;양진승
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.291-296
    • /
    • 2000
  • Usually the contact between fin collar and tube surface for fin-tube heat exchanger is secured by mechanical expansion of the tubes. The objective of the present study is to develop a method of measuring the thermal contact resistance between fin collar and tube surface for fin-tube heat exchanger. Also an experimental work has been performed to evaluate the thermal contact resistance, and a rigorous numerical analysis has been employed to calculate the contact resistance from the measured data. The experiments have been conducted fur the fin-tube heat exchangers with the tube of outer diameters 7 and 9.52 mm.

  • PDF

비원형 관출구로부터 방출되는 펄스파의 특성에 관한 연구 (Study on the Characteristics of Impulse Wave Discharged from the Tube Exit with Non-Circular Cross-Section)

  • 신현동;권용훈;이영기;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.550-555
    • /
    • 2003
  • When a shock wave arrives at an open end of tube, an impulse wave is discharged from the tube exit and complicated flow is formed near tube exit. The flow field is influenced by the cross-sectional geometry of tube exit, such as circular, square, rectangular, trapezoid and etc. In the current study, three-dimensional propagation characteristics of impulse wave discharged from the tube exit with non-circular cross section are numerically investigated using a CFD method. Total variation diminishing (TVD) scheme is used to solve the three-dimensional, unsteady, compressible Euler equations. Computations are performed for the Mach numbers of the incident shock wave $M_{s}$ below 1.5. The results obtained show that the peak pressure of the impulse wave and propagation directivity depends on the cross-sectional geometry of tube exit and the Mach number of incident shock wave.

  • PDF

삼차원 조도관의 압력손실 및 열전달 성능에 대한 실험적 연구 (An Experimental Study on the Pressure Drop and Heat Transfer Performance in Tubes with Three Dimensional Roughness)

  • 김내현
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.276-286
    • /
    • 1995
  • In this study, pressure drop and heat transfer coefficients were measured in tubes with three dimensional roughness. Dimples were made by rotating the saw-tooth shaped finning disc on the outer tube surface. Resultant dimple shape was oval. Friction and heat transfer tests were performed with a range of roughness variables-roughness height 'e', axial roughness pitch 'p', circumferential roughness pitch 'z'. Within the test range, tube with e=0.5mm, z=5mm, p=3mm performed best. The efficiency ratio(rati of the heat transfer improvement and the pressure drop increase) of the tube approached 1.0 at low Reynolds number, and it was higher than that of the two-dimensional roughess tube of the same roughness height. Test data were predicted by 'discrete element method'. Results show that discrete element method underpredicts the friction data by 2% to 32%, and overpredicts the heat transfer data by-12% to 113%.

  • PDF

냉매의 불균일한 분배가 증발기의 성능에 미치는 영향 (Effects on Refrigerant Maldistribution on the Performance of Evaporator)

  • 김창덕;이진호
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.230-240
    • /
    • 2004
  • An experimental investigation was conducted to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R22. A comparison was made between the predictions by previously proposed tube-by-tube method and experimental data for the heat transfer rate of evaporator. Experiments were carried out under the conditions of saturation temperature of 5$^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of 27$^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71㎧. Experiment show that air velocity increased by 85.2% is need for T-type distributor with four outlet branches than that of two outlet branches under the superheat of 5$^{\circ}C$, which resulted in air-side pressure drop increase of 130% for T-type distributor with four outlet branches as compared to two outlet branches.

A SIMPLIFIED METHOD TO PREDICT FRETTING-WEAR DAMAGE IN DOUBLE $90^{\circ}$ U-BEND TUBES

  • Choi, Seog-Nam;Yoon, Ki-Seok;Choi, Taek-Sang
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.616-621
    • /
    • 2003
  • Fluid-elastic instability is believed to be a cause of the large-amplitude vibration and resulting rapid wear of heat exchanger tubes when the flow velocity exceeds a critical value. For sub-critical flow velocities, the random turbulence excitation is the main mechanism to be considered in predicting the long-term wear of steam generator tubes. Since flow-induced interactions of the tubes with tube supports in the sub-critical flow velocity can cause a localized tube wear, tube movement in the clearance between the tube and tube support as well as the normal contact force on the tubes by fluid should be maintained as low as possible. A simplified method is used for predicting fretting-wear damage of the double $90^{\circ}$U-bend tubes. The approach employed is based on the straight single-span tube analytical model proposed by Connors, the linear structural dynamic theory of Appendix N-1300 to ASME Section III and the Archard's equation for adhesive wear. Results from the presented method show a similar trend compared with the field data. This method can be utilized to predict the fretting-wear of the double $90^{\circ}$U-bend tubes in steam generators.

  • PDF

Derivation of design charts based on the two-dimensional structural analysis of geotextile tubes

  • Kim, Hyeong-Joo;Won, Myoung-Soo;Park, Tae-Woong;Choi, Min-Jun;Jamin, Jay C.
    • Structural Engineering and Mechanics
    • /
    • 제55권2호
    • /
    • pp.349-364
    • /
    • 2015
  • Analytical solutions for modeling geotextile tubes during the filling process and approximation method to determine the densified tube shape are reviewed. The geotextile tube filling analysis is based on Plaut & Suherman's two-dimensional solution for geotextile tubes having a weightless and frictionless inextensible membrane resting on a rigid horizontal foundation subjected to internal and external hydrostatic pressures. The approximation for the densified tube shape developed by Leshchinsky et al. was adopted. A modified method for approximating the densified tube shape based on an areal-strain deformation analysis is introduced. Design diagrams useful for approximating geotextile tube measurements in the design process are provided.

Efficacy of an assistive guide tube for improved endoscopic access to gastrointestinal lesions: an in vivo study in a porcine model

  • Dong Seok Lee;Jeong-Sik Byeon;Sang Gyun Kim;Ji Won Kim;Kook Lae Lee;Ji Bong Jeong;Yong Jin Jung;Hyoun Woo Kang
    • Clinical Endoscopy
    • /
    • 제57권1호
    • /
    • pp.82-88
    • /
    • 2024
  • Background/Aims: Guide tube-assisted endoscopy for procedures that require repeated endoscopic access is safer and more effective than conventional endoscopy. However, its effectiveness has not been confirmed in animal studies. We assessed the usefulness of guide tube-assisted endoscopic procedures in an in vivo porcine model. Methods: Five different guide tube-assisted endoscopic procedures were performed by experienced endoscopists on a pig weighing 32 kg. To evaluate the efficacy of these procedures, we compared the endoscopic approach time when a guide tube was used to that when it was not. Additional endoscopic procedures using a guide tube were performed, including multiple foreign body extractions, multiple polypectomies, and multiple submucosal dissections. To evaluate safety, we compared the insertion force into the proximal esophagus between the guide tube and conventional overtube methods. Results: Using the endoscopic approach with a guide tube required a shorter average approach time to reach the three target lesions than when using the endoscopic approach without a guide tube (p<0.001). Compared to the conventional overtube method, the guide tube method produced a lower average resistance during insertion into the upper esophagus (p<0.001). Conclusions: Guide tube-assisted endoscopic procedures are effective and safe for repeated endoscopic access in an in vivo porcine model.

지하수의 CFCs(Chlorofluorocarbons) 조사를 위한 시료 채취 방법의 평가 (Evaluation of Ground-Water Sampling Techniques for Analysis of Chlorofluorocarbons)

  • 고동찬;이대하
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제8권2호
    • /
    • pp.1-8
    • /
    • 2003
  • Chlorofluorocarbons(CFCs) 조사를 위한 지하수 시료 채취 방법 중 cold-welded copper tube method(구리관법)과 flame-sealed borosilicate glass ampule method(유리앰퓰법)의 두 방법을 비교하고 검토하였다. 구리관법에 의해 채취된 시료의 CFCs 농도는 중복시료간에 재현성이 불량한 반면, 유리앰퓰법은 상대표준오차가 5% 이내로 좋은 재현성을 보여주었다. 이것은 구리관법을 적용할 때, 관정의 출수구와 구리관의 연결의 밀봉성이 좋지 않았기 때문인 것으로 추정된다. 또한 구리관법에 의한 CFCs 농도는 전체적으로 유리앰퓰에 의한 값보다 높았으며 이러한 특징은 CFC-11이 CFC-12보다 더 두드러졌다. 구리관법의 경우에 플라스틱 관이나 관정에 설치된 출수구에 포함된 고무 패킹 등이 시료를 CFCs로 오염시켰을 것으로 평가된다. 유리앰퓰법을 적용했을 때에는 이러한 가능성을 제거하기 위해 stainless steel과 nylon 재질만을 이용하고, 시료채취장비를 관정의 주배수관에 직접 연결하였다. 인위적인 공급원에 의한 CFCs가 없을 것으로 예상되는 시료에서 유리앰퓰법에 의해 매우 낮은 수준의 CFCs농도가 측정됨으로써 이 시료채취과정의 유효성이 검증되었다.

대구경 타원관을 적용한 건조기용 핀-관 열교환기의 성능특성 (Performance Characteristics of Fin-Tube Heat Exchanger having Large Diameter Oval Tube for Dryer)

  • 배경진;차동안;권오경
    • 설비공학논문집
    • /
    • 제27권1호
    • /
    • pp.8-13
    • /
    • 2015
  • The objective of this paper is to provide design data of fin-tube heat exchanger which have a large diameter oval tube for dryer application. In this study, the heat transfer and pressure drop performance characteristics of the fin-tube heat exchanger were compared with Dittus-Boelter and a new correlation equation using Wilson plot method. The simulation results based on section by section method were compared with experimental results. These results showed that a new correlation equation using Wilson plot method provided better prediction, about 3 to 12%, than the Dittus-Boelter equation, from the experiment comparison. Also, the pressure drop of simulation results showed much more deviation with the experimental results.