• Title/Summary/Keyword: Tube Integrity Assessment

Search Result 38, Processing Time 0.019 seconds

High-Temperature Design of Sodium-to-Air Heat Exchanger in Sodium Test Loop (소듐 시험루프 내 소듐대 공기 열교환기의 고온 설계)

  • Lee, Hyeong-Yeon;Eoh, Jae-Hyuk;Lee, Yong-Bum
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.665-671
    • /
    • 2013
  • In a Korean Generation IV prototype sodium-cooled fast reactor (SFR), various types of high-temperature heat exchangers such as IHX (intermediate heat exchanger), DHX (decay heat exchanger), AHX (air heat exchanger), FHX (finned-tube sodium-to-air heat exchanger), and SG (steam generator) are to be designed and installed. In this study, the high-temperature design and integrity evaluation of the sodium-to-air heat exchanger AHX in the STELLA-1 (sodium integral effect test loop for safety simulation and assessment) test loop already installed at KAERI (Korea Atomic Energy Research Institute) and FHX in the SEFLA (sodium thermal-hydraulic experiment loop for finned-tube sodium-to-air heat exchanger) test loop to be installed at KAERI have been performed. Evaluations of creep-fatigue damage based on full 3D finite element analyses were conducted for the two heat exchangers according to the high-temperature design codes, and the integrity of the high-temperature design of the two heat exchangers was confirmed.

Evaluation of Nondestructive Evaluation Size Measurement for Integrity Assessment of Axial Outside Diameter Stress Corrosion Cracking in Steam Generator Tubes (증기발생기 전열관 외면 축균열 건전성 평가를 위한 비파괴검사 크기 측정 평가)

  • Joo, Kyung-Mun;Hong, Jun-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • Recently, the initiation of outside diameter stress corrosion cracking (ODSCC) at the tube support plate region of domestic steam generators (SG) with Alloy600 HTMA tubes has been increasing. As a result, SGs with Alloy600 HTMA tubes must be replaced early or are scheduled to be replaced prior to their designed lifetime. ODSCC is one of the biggest threats to the integrity of SG tubes. Therefore, the accurate evaluation of tube integrity to determine ODSCC is needed. Eddy current testing (ECT) is conducted periodically, and its results could be input as parameters for evaluating the integrity of SG tubes. The reliability of an ECT inspection system depends on the performance of the inspection technique and abilty of the analyst. The detection probability and ECT sizing error of degradation are considered to be the performance indices of a nondestructive evaluation (NDE) system. This paper introduces an optimized evaluation method for ECT, as well as the sizing error, including the analyst performance. This study was based on the results of a round robin program in which 10 inspection analysts from 5 different companies participated. The analysis of ECT sizing results was performed using a linear regression model relating the true defect size data to the measured ECT size data.

Development of an Integrity Evaluation System (WIES) for Fuel Channels in CANDU Reactors (중수로 연료관 건전성 평가시스템(WIES) 개발)

  • Choi, Sung-Nam;Kim, Hyung-Nam;Yoo, Hyun-Joo;Kwon, Dong-Kee;Hwang, Won-Gul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1273-1279
    • /
    • 2010
  • Pressure tubes at the CANada Deuterium Uranium (CANDU) nuclear power plants are periodically inspected in accordance with the CSA N285.4 code. If flaws that do not satisfy the criteria given in CSA N285.4 are detected, the code permits a fitness-for-service assessment to determine the acceptability of the flawed pressure tubes. In this paper, the Wolsong In-service Evaluation System (WIES) is introduced; this system has been developed for the assessment of the flawed pressure tubes and is based on CSA N285.8. Since the system evaluates the integrity of flawed pressure tubes exactly and promptly during an in-service inspection, it will help in operating the Wolsong nuclear power plants without prolonging the outage period.

Burst Pressure Evaluation for Through-Wall Cracked Tubes in the Steam Generator (관통균열이 존재하는 증기발생기 전열관의 파열압력 평가)

  • Kim, Hyun-Su;Kim, Jong-Sung;Jin, Tae-Eun;Kim, Hong-Deok;Chung, Han-Sup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.7
    • /
    • pp.1006-1013
    • /
    • 2004
  • Operating experience of steam generators shows that the tubes are degraded by stress corrosion cracking, fretting wear and so on. These defected tubes could stay in service if it is proved that the tubes have sufficient structural margin to preclude the risk of tube bursting. This paper provides detailed plastic limit pressure solutions for through-wall cracks in the steam generator tubes. These are developed based on three dimensional(3D) finite element analyses assuming elastic-perfectly plastic material behavior. Both axial and circumferential through-wall cracks in free span and in u-bend regions are considered. The resulting limit pressure solutions are given in a polynomial form, and thus can be simply used in practical integrity assessment of the steam generator tubes.

Burst Behavior of Wear Scar of Steam Generators Tubes (증기발생기 전열관 마모 파열 거동)

  • Kim, Hong-deok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • Nuclear steam generator tubes have experienced wear degradation at tube support structure. Morphology of wear scar was analyzed by using eddy current signal. A burst test facility for steam generator tubes was established and tubes with 3 types of defects were tested. The burst test results show that the depth of wear scar is the main factor influencing the burst pressure of tubes, meanwhile, both the longitudinal length and the angle also have effect on the burst pressure. Based on test results, the burst pressure equation for wear degradation was proposed.

  • PDF

Depth-Sizing Technique for Crack Indications in Steam Generator Tubing (증기발생기 전열관 균열깊이 평가기술)

  • Cho, Chan-Hee;Lee, Hee-Jong;Kim, Hong-Deok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.98-103
    • /
    • 2009
  • The nuclear power plants have been safely operated by plugging the steam generator tubes which have the crack indications. Tube rupture events can occur if analysts fail to detect crack indications during in-service inspection. There are various types of crack indication in steam generator tubes and they have been detected by the eddy current test. The integrity assessment should be performed using the crack-sizing results from eddy current data when the crack indication is detected. However, it is not easy to evaluate the crack-depth precisely and consistently due to the complexity of the methods. The current crack-sizing methods were reviewed in this paper and the suitable ones were selected through the laboratory tests. The retired steam generators of Kori Unit 1 were used for this study. The round robin tests by the domestic qualified analysts were carried out and the statistical models were introduced to establish the appropriate depth-sizing techniques. It is expected that the proposed techniques in this study can be utilized in the Steam Generator Management Program.

Application of Multiparametric Flow Cytometry (FCM) to Enumerate the Diagnosis of Pseudomonas aeruginosa and Escherichia coli

  • Hwang, Myoung-Goo;Oh, Jung-Woo;Katayama, Hiroyuki;Ohgaki, Shinichiro;Cho, Jin-Kyu
    • Environmental Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.35-39
    • /
    • 2012
  • In this study, multiparametric flow cytometry (FCM) was installed to enumerate the diagnosis of Pseudomonas aeruginosa ATCC 10145 and Escherichia coli K12 (IFO 3301). The nucleic acids (DNA/RNA) were double stained by a LIVE/DEAD bacLight viability kit, involving green SYTO 9 and red propidium iodide (PI), based on the permeability of two chemicals according to the integrity of plasma membrane. As the results showed, the gate for dead bacteria was defined as the range of $0.2{\times}10^0$ to $6.0{\times}10^1$ photo multiplier tube (PMT) 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $2.0{\times}10^2$ PMT 4 fluorescence (Y-axis), and the gate for live bacteria was defined as the range of $6.0{\times}10^0$ to $6.0{\times}10^2$ PMT 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $4.0{\times}10^2$ PMT 4 fluorescence (Y-axis). In the comparison of the number of the tested bacteria detected by FCM (viability assessment) and plate culture (cultivability assessment), the number of bacteria detected by FCM well represented the number of bacteria that was detected by the colony forming unit (CFU) counting method when bacteria were exposed to isopropyl alcohol and silver/copper cations. Consequently, it is concluded that the application of FCM to monitor the functional effect of disinfectants on the physiological status of target bacteria can offer more rapid and reliable data than the plate culture colony counting method.

A Study for the Present Conditions and the Service Satisfaction with Hospital Home Care Service (병원가정간호사업 운영 현황 및 서비스 만족도에 관한 연구)

  • Hong, Chun-Sil;Oh, Kyong-Ok;Park, Mi-Young;Sim, Hee-Sook;Cha, Young-Nam
    • Journal of Home Health Care Nursing
    • /
    • v.8 no.2
    • /
    • pp.121-134
    • /
    • 2001
  • The purpose of this study were to analyze the home care services and to evaluate the client's satisfaction with the home care services provided by home care service center in the C hospital. The data were collected by reviewing charts of 128 home care clients who were receiving home care services at C hospital from October 1997 to September 2000. The subjects for satisfaction of home care service were 20 clients from July 10 to September 30, 2000. The tool for measurement of present condition of home care service was developed by the researchers. The satisfactions of the home care services were measured by using the instrument developed by Im(997). The data were analyzed by using the SPSS/PC+. The results of this study were as followings : 1. Majority of the subjects was female(61.7%). The average of age was 63.5 years. The service has been used mostly by the elderly 60 years of age or older(71.1%). The economic level of most of subjects was in middle class(94.5%). 2. Majority of the subject had a cancer(55.4%), following stroke(25.0%). The average duration of disease for the subjects was 31 months. The average time of hospitalization for the subjects was 3.3 times. The duration of hospitalization was 10$\sim$30 days(26.6%), 30$\sim$60 days(23.4%) and above of the 210 days(9.4%). 3. Most of the subjects used his/her doctor (47.7%), as a consultant, following his/her nurse (28.1%), other patients or their family (21.9%). Most of reasons for a consultation were supportive management(Infusion or medication, 60.94%), following tube management(L-tube or T-tube, 25%), Foley catheter management (15.63%) etc. 4. 28 types of nursing diagnoses were used by the home care service. The nursing diagnosis altered nutrition: less than body requirement were used mostly by the home care service, following risk for infection, impaired skin integrity, impaired swallowing, ineffective airway clearance altered comfort: pain, impaired physical mobility. By the human-response pattern, exchanging(63.2%), moving(7.5%), feeling(10.4%), knowing(5.2%), communicating (2.6%), relating(0.5%) perceiving(0.4%) and choosing(0.3%). There were 42 nursing intervention types were performed by the home care service. By the NIC(nursing intervention classification. McCloskey. Bulech. 1996). physiologic: complex (30.3%) was the most, safety(28.3%), behavioral(20.0%), physiologic: basic(10.8%) and health system(1.7%). Observation or assessment was the most nursing intervention performed by the home care service. following IV infusion. vital sign observation. infusion management and fluid-electrolyte balance management. 5. The level of client's satisfaction with provided home care services showed considerably high(2.67/ 3).