• Title/Summary/Keyword: Tube Arrangement

Search Result 100, Processing Time 0.019 seconds

Heat transfer with geometric shape of micro-fin tubes (I) - Condensing heat transfer - (마이크로핀 관의 기하학적 형상변화에 대한 열전달 특성 (I) - 응축 열전달 -)

  • Kwak, Kyung-Min;Jang, Jae-Sik;Bae, Chul-Ho;Jung, Mo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.774-788
    • /
    • 1999
  • To examine the enhancement mechanism of condensing heat transfer through microfin tube, the condensation experiments with refrigerant HCFC 22 are performed using 4 and 6 kinds of microfin tubes with outer diameter of 9.52mm and 7.0mm, respectively. Used microfin tubes have different shape and number of fins with each other The main heat transfer enhancement mechanism is known to be the enlargement of heat transfer area and turbulence promotion. Together with these main factors, we can find other enhancement factors by the experimental data, which are the overflow of the refrigerant over the microfin and microfin arrangement. The overflow of the refrigerant over the microfin can be analyzed by the geometric shape of the microfin. Microfin tubes having a shape which can give much overflow over the microfin show large condensing heat transfer coefficients. The effect of microfin arrangement is related to the heat transfer resistance of liquid film of refrigerant. The condensing heat transfer coefficients are high for the microfin tube with even distribution of liquid film.

  • PDF

A Numerical Study of 3-D Flows in Spiral Tubes with Square Cross-Section (Spiral Tube 내에서의 3차원 유동 해석)

  • Hur Nahmkeon;Kim Seongwon
    • Journal of computational fluids engineering
    • /
    • v.4 no.1
    • /
    • pp.27-33
    • /
    • 1999
  • Spiral tube heat exchangers can find numerous applications in many engineering fields. Flow in spiral tubes is interest to engineers due to occurrence of secondary flow which enhances the cross-sectional mixing and the heat transfer rate. In the present study, an incompressible viscous 3-D flow in spiral tubes with rectangular cross-section of various torsion rate and Reynolds number is studied by using a finite volume method. It is shown that the axial velocity profile is affected by the secondary flow motion. Because there is some difference from correlation proposed by Hur et al., a lot of analysis and arrangement of experimental results are needed. This study showed the results of variation of hydrodynamic entry length for torsion and Re numbers.

  • PDF

Parametric Study on the $LiBr-H_{2}O$ Absorption Process on Horizontal Tubes Using Wavier-Stokes Equations (Navier-Stokes 방정식을 사용한 수평원관상의 $LiBr-H_{2}O$ 흡수특성에 대한 연구)

  • Min J. K.;Choi D. H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.213-218
    • /
    • 1999
  • The $LiBr-H_{2}O$ absorption process on a horizontal tube has been analyzed using the numerical method which incorporates the fully elliptic Navier-Stokes equations for the momentum equations, the energy and mass-diffusion equations. On a staggered grid, the SIMPLER algorithm with the QUICK scheme is used to solve these equations along with the MAC method for the free surface tracking. With the assumption that the absorbent is linear, calculations have been made for various inlet temperature and flow-rate conditions. The detailed results of the parametric study, such as the temperature, concentration, absorption mass flux and wall heat flux distributions are presented. The self-sustained feature of the absorption process is clearly elaborated. The analyses have also been carried out for multiple tube arrangement and the results show that the absorption rate converges after a few tube rows.

  • PDF

A study on the single-phase heat transfer in a counter-flow double-pipe heat exchanger by Wilson plot technique (Wilson plot기법을 이용한 2중관식 대향류 열교환기의 단상 열전달에 관한 연구)

  • Ohm, Ki-Chan
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.93-100
    • /
    • 2006
  • An experimental study of a counterflow heat exchanger was performed. The heat exchanger had an effective heat transfer length of 1000mm and was operated in a counterflow arrangement with hot water($30{\pm}0.5^{\circ}C$, $Re_i=3500{\sim}20000$) in the inner tube(copper tube, $d_0=9.52mm$) and cold water($15{\pm}0.5^{\circ}C$, $Re_{DH}=10700{\sim}39000$) in the annulus(copper tube, $D_0=19.05mm$). Overall heat transfer coefficients were calculated and heat transfer coefficients in the inner tube and the annulus were determined using Wilson plots. The inner Nusselt number was compared with that of Gnielinski's correlation and they agreed within ${\pm}10%$ error. The trends were typical for a fluid-to-fluid heat exchanger with the overall heat transfer coefficient increasing with both inner and annulus flow rates. In the range of this experiment, Nusselt numbers for the inner tube flow were almost identical with those of the annulus flow at the same Reynolds number.

Effects on Refrigerant Maldistribution on the Performance of Evaporator

  • Lee, Jin-Ho;Kim, Chang-Duk;Byun, Ju-Suk;Jang, Tae-Sa
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.2
    • /
    • pp.107-118
    • /
    • 2005
  • An experimental investigation was made to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R-22. Experiments were carried out under the conditions of saturation temperature of $5^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of $27^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71m/s. A comparison was made between the predictions from the previously proposed tube-by-tube method and the present experimental data for the heat transfer rate of evaporator. Results show that $82.5\%$ increase of air velocity is needed for T-type distributor with four outlet branches than that of two outlet branches under the superheat of $5^{\circ}C$, which resulted in increasing of air-side pressure drop of $130\%$ for the former as compared to the latter.

An Experimental Study of Fouling Effect on the Heat Transfer Around a Tube in Staggered Tube Banks (엇갈림 관군에서 원관 주위의 열전달에 미치는 파울링 영향에 관한 실험적 연구)

  • Kim, Min-Su;Baek, Byeong-Jun;Park, Bok-Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.11
    • /
    • pp.1478-1485
    • /
    • 2000
  • An experimental study has been performed to investigated the forced convection heat transfer characteristics of 6 circular cylinders in staggered arrangement in a cross flow of air. The water scale deposited on condenser wall of power plant was used to investigate the effect of roughness of scaled surfaces. The relative roughness*average diameter of scale/cylinder diameter) was in a range of k/d=0.0066, 0.0111, 0.0167, 0.0222 and 0.0278. The cylinder spacings(L/d) varies from 1.5 to 4.0 where L denote the cylinder spacings along and normal to the upstream uniform flow direction. The Reynolds number was varied in a range of 10, 000$\leq$ Re $\leq$ 50,000. The local and mean Nusselt numbers were investigated as a function of scale roughness, the cylinder spacing and Reynolds number. The results are compared with those of clean cylinder and inline tube bank, subsequently the mean fouling resistance over the entire circumference was estimated from those results as a function of scale roughness, the cylinder spacing and Reynolds number.

Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR (소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계)

  • Kim, Nak Hyun;Lee, Sa Yong;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

Forced Convection Heat Transfer for Two Circular Tube Arrays with Annular Fins (환형휜이 부착된 두 개의 원형관 배열에 대한 강제대류 열전달)

  • Kim, Seung-iI;Park, Sang-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.1093-1101
    • /
    • 2020
  • This study was carried out numerically to investigate the air flow and thermal performance around single and parallel fin-tube heat exchangers and the cooling performance of the fluid inside the heat exchangers. In this study, the air velocity(1~7m/s), the pitch of fin(4, 6.1, 8, 11.3, 18.3, 44mm) and the diameter of fin(31, 33, 35, 37, 39mm) were varied. The flow rate of the water at the fin-tube heat exchanger inlet is 89cc/min and the water temperature is 353K. The air temperature at the upstream region of the heat exchanger is 300K. flow rate of the water at the fin-tube heat exchanger inlet is 80cc/min and the water temperature is 353K. It was found that the air pressure drop around single and parallel fin-tube heat exchangers was highly dependent on the air velocity and the fin pitch, but was independent of the fin diameter. Also, it was shown that pressure drop increased more the parallel arrangements than in single heat exchanger. The temperature difference of water at the inlet and outlet of the heat exchanger depended on the air velocity, the fin pitch and the fin diameter, and it was found that the parallel arrangement method further reduced the temperature of water. It was shown that the Nusselt number increased as the Reynolds number and the fin pitch increased, and decreased as the fin diameter increased.

A numerical study of turbulent flows with adverse pressure gradient (역압력 구배가 있는 난류유동에 대한 수치적 연구)

  • 김형수;정태선;최영기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.668-676
    • /
    • 1991
  • Turbulent flows around tube banks and in the diffuser were studied using a non-orthogonal boundary fitted coordinate system and the modified K-.epsilon. turbulence model. In these cases, many problems emerge which stem from the geometrical complexity of the flow domain and the physical complexity of turbulent flow itself. To treat the complex geometry, governing equations were reformulated in a non-orthogonal coordinate system with Cartesian velocity components and discretised by the finite volume method with a non-staggered variable arrangement. The modified K-.epsilon. model of Hanjalic and Launer was applied to solve above two cases under the condition of strong and mild pressure gradient. The results using the modified K-.epsilon. model results in both test cases.

A Study on the Space Composition and Furniture Arrangement of Preschooler's Library (유아도서관의 공간구성과 가구배치 유형 계획을 위한 연구)

  • 박지민;윤정숙
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.127-136
    • /
    • 2003
  • The purpose of this study is to establish concept about a plan direction of preschooler's library, and provide a design type of preschooler's library. As a result, the following findings were obtained: 1) For the preschooler's reading area, it should be segregated between schooler and preschooler. Because there is a difference between a library use action and a development characteristic, it needs to be segregated to avoid conflict using library for both of those groups. 2) The space composition of preschooler's library stands up, and of a tube considers a traffic line of a user according to the function and systematizes a child, and to cause an interest of preschoolers. 3) Furnitures and equipment of preschooler's library must arrange in consideration of human body size of a user in a tube.