• Title/Summary/Keyword: Tube Arrangement

Search Result 99, Processing Time 0.024 seconds

Numerical Study of Liquid Film Flow on Heat Exchanger Tube Arrangement and Configuration of Multi Effect Distillation (증발식 다중효용 담수기에서 열교환기 튜브 배열 및 형상에 따른 액막 유동에 관한 수치해석)

  • Jung, Il-Young;Yun, Sang-Kook;Joo, Hong-Jin;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.68-73
    • /
    • 2011
  • This study was performed numerical analysis in order to analyze liquid film flow of heat exchanger tube arrangement and configuration of evaporative multi effect distillation system using medium-temperature. Simulation was accomplished the two-dimensional calculations using commercial analyses program FLUENT based on the FVM(finite volume method). Fresh water generator of this study used Shell & Tubes heat exchanger with Cu_Ni tube, configuration of tube used bare tube and corrugated tube, and arrangement of tube used in-line array and staggered array. Performance of heat exchanger through the formation of liquid film was compared and analyzed. Liquid film flow occurred that falling on heat exchanger tube wall. Result of simulation showed that liquid film thickness of in-line arrangement was found 0.57mm with bare tube and 0.67mm with corrugated tube, respectively. And liquid film thickness of staggered arrangement was found 0.39mm with bare tubes and 0.62mm with corrugated tubes, respectively. Liquid film thickness of corrugated tube showed thicker than bare tube, but heat transfer rates of corrugated tube showed higher than bare tube. The reason was considered that surface area of corrugated tube was wider than bare tube. And liquid film thickness of staggered arrangement showed thinner than in-line arrangement, so thermal performance of staggered arrangement showed higher than in-line arrangement.

  • PDF

${\Alpha} - Al_2O_3$ tube shaped single crystal growth by the EFG method (EFG법에 의한 ${\Alpha} - Al_2O_3$ tube 단결정 성장)

  • 박한수;한종원;전병식;오근호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.5 no.1
    • /
    • pp.11-18
    • /
    • 1995
  • Abstract ${\Alpha} - Al_2O_3$ tube shaped single crystals were grown by the EFG method. By using two different heating arrangement, tube shaped single crystals were grown. Comparing the grown tube shaped single crystals, tube crystal growth conditions were established.

  • PDF

Heat Transfer Characteristics according to the Tube Arrangement of Bundle Type Plastic Oil Cooler (플라스틱 관다발 타입 오일쿨러의 튜브 배열에 따른 열전달 특성)

  • Heo, Hyung-Seok;Bae, Suk-Jung;Kim, Hyun-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • It has been argued that the use of plastics can cause problems during design and manufacture owing to their low strength, relatively poor thermal conductivity and large thermal expansion. However, the advantages of plastics e.g., corrosion resistance, low cost, curtailment of weight, design flexibility etc., can compensate abundantly for the disadvantages. This study analyzes and compares the heat transfer performance characteristics of automotive compact oil cooler composed of plastic tube bundle with conventional metal oil cooler on the same core area basis as diameter, tube thickness, number of tube or tube arrangement varies. The performance analyses are accomplished by use of computational fluid dynamics program Fluent 6.2, which is verified and compared with the results of performance tests. The result of analyses is coincided with that of experiments. Flow pattern at air side according to tube arrangement is dominant factor which affects heat dissipation in case of similar total heat transfer surface area.

The Visualization of the Flowfield through Tube Banks with In-line and Staggered Arrangements Using the PIV (PIV를 이용한 정렬 및 엇갈림 배열을 가진 관군을 지나는 유동장의 가시화)

  • Ro, Ki-Deok;Park, Ji-Tae;Byun, Yong-Sue
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.44-51
    • /
    • 2009
  • The Characteristics of the flowfield through tube banks with in-line and staggered arrangements were investigated by PIV. Strouhal numbers, velocity vectors and velocity profiles around the cylinders with in-line and staggered arrangements were observed at the pitch ratio Pt/D=2.0 and Reynolds number of Re=$Re=4.0{\times}10^3$. As the results The flow patterns through tube banks were almost a straight line in case of the in-line arrangement while it was almost 八 type in case of the staggered arrangement in the direction of the wake. The average velocity in the rear region of the tube banks with the staggered arrangement was far smaller than that with the in-line arrangement. The Strouhal number in the last rank was far smaller than that in the front ranks in both of the in-line and staggered arrangements. The wake of each cylinder changed with time and with the position of the cylinder.

The Visualization of the Flow through Tube Banks in Various Arrangements (다양한 배열 상태에 놓인 관군을 지나는 흐름의 가시화)

  • Ro, Ki-Deok;Gong, Tae-Hee;Jeoi, Jeong-Gi;Kim, Seong-Jae;Kim, Tae-Kyeung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2530-2535
    • /
    • 2008
  • The Visualizations of the flowfield through tube banks with in-line and staggered arrangements were investigated by PIV. Strouhal numbers, velocity vectors and velocity profiles around the cylinders with in-line and staggered arrangements were observed at the pitch ratio $P_t/D=2.0$ and Reynolds number of $Re=4.0{\times}10^3$. As the results The flow patterns through tube banks were almost a straight line in case of the in-line arrangement while it was almost 八 type in case of the staggered arrangement in the direction of the wake. The average velocity in the rear region of the tube banks with the staggered arrangement was far smaller than that with the in-line arrangement. The Strouhal number in the last rank was far smaller than that in the front ranks in both of the in-line and staggered arrangements. The wake of each cylinder changed with time and with the position of the cylinder.

  • PDF

The Convective Heat Transfer for the Flow Perpendicular to the Tube Array (튜브배열 방향과 수직한 유동에 의한 관외 대류 열전달)

  • Jeon Yong-Han;Kim Jong-Yoon;Kim Nam-Jin;Kim Chong-Bo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.656-663
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the flow has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mean Nusselt number of the former was greater than that of the latter. It is verified that the results obtained by using the simulation show the same tendency with those of experiment.

A Study on the Performance of a Cross-Flow Beat Exchanger by Tube Array Change (튜브배열 변화에 따른 직교류형 열교환기의 성능에 관한 연구)

  • Jeon Yong-Han;Kim Nam-Jin;Kim Chong-Bo
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.28-34
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the Hour has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mom Nusselt number of the former was greater thu that of the latter.

Effect of Arrangement of Heat Transfer tube on the Thermal Performance for the High Temperature Generator (전열관 배열에 의한 고온재생기 열적 성능 변화)

  • Lee, In-Song;Cho, Keum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.266-271
    • /
    • 2009
  • The present study numerically investigated the effect of the geometry of the flattened tube on the thermal performance of a high temperature generator (HTG) of a double effect LiBr-water absorption system. The heat transfer tubes of the HTG were arranged behind a metal fiber burner. The heat transfer of the tubes of HTG were consisted with a set of circular and flattened tubes in series. FLUENT, as a commercial code, was applied for estimating the thermal performance of the HTG. Key parameters were the tube arrangement in the HTG. Temperature and velocity profiles in the HTG were calculated to estimate the thermal performance of the HTG. The heat transfer rate of a HTG tube was increased, and the gas temperature around the flattened tube was decreased as the pitch ratio was increased. The heat transfer rate for the circular tube bundle with the pitch ratio of 2.48 were larger by 10% respectively than that of 2.10 and the heat transfer rate for the flattened tube bundle with the pitch ratio of 1.88 were larger by 36% respectively than that of 1.63.

  • PDF

The Effects of Tube Arrangement and Inclination on the Pressure Drop in Tube Bundles of Intermediate Beat Exchanger in Liquid Meta Reactor (액체금속로 중간열교환기 관다발에서의 튜브배열과 경사각도가 압력강하에 미치는 영향)

  • Nam Ho Yun;Kim Jong Man;Choi Jong Hyeun
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.659-662
    • /
    • 2002
  • The present paper presents the experimental results for pressure drop in inclined tube bundles located in a rectangular duct. Measurements are made for pressure drop in triangular and rotated triangular tube arrays having P/d ratio of 1.6 and inclination angles of 30,45,60 and 90 degrees. The Reynolds number based on the free stream velocity and tube diameter ranges from $8{\times}10^2\;to\;6.3{\times}10^{4}$. The experimental results show that the magnitude of dimensionless pressure drop decreases significantly when the inclined angle is less than 45 degree. The measured data are compared with two existing correlations available in the literatures. The ESDU correlation agrees well with the present data far the triangular arrays. But some discrepancies are observed for the rotated triangular arrays when the inclined angles are 30 and 45 degrees. The Idel'chik correlation generally agrees well with the measured data for the rotated triangular arrays except for the inclined angle of 30 degree. The Idel'chik correlation needs modification for the triangular arrays. The modified Idel'chik correlation agrees well with the measured data within $10{\%}$. It is found that the present measured data can be applied to the evaluation and modification of previous correlations.

  • PDF

Numerical Simulation of Heat Transfer Characteristics of Tube Banks with Non-conventional Arrangement (튜브뱅크 배열특성에 따른 전열특성변화 수치모사)

  • Jun, Yong-Du;Nam, Myong-Hwan;Koo, Byeong-Soo;Lee, Kum-Bae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1129-1134
    • /
    • 2009
  • A numerical study has been conducted to investigate the effect of tube arrangement on the heat transfer and the pressure loss for cross flow heat exchangers. By defining a transverse deviation factor, ${\varepsilon}_t=l_T/S_T$, the flow pattern and the heat transfer characteristics are compared for selected ${\varepsilon}_t$ values of 0.0(in-lined), 0.1, 0.2, 0.3, 0.4, 0.5(staggered) by using a commercial software. Computational domain includes 1 pitch in the transverse direction and 5 pitches in the flow direction with due periodic boundary conditions.

  • PDF