• Title/Summary/Keyword: Tripping characteristics

Search Result 41, Processing Time 0.02 seconds

Study on the Ground Fault Protection in 6.6KV Ungrounded Power System SGR Malfunction or Non-Tripping (선택지락보호계전기 오.부동작에 관한 연구)

  • Kim, Byung-Tae;Lee, Dal-Woo;Jeon, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.296-301
    • /
    • 2008
  • This paper presents a study on the ground fault protection in 6.6KV ungrounded power system relay(SGR) malfunction or non-tripping. Ground test had made on 6.6KV HV(high voltage) system, Some of domestic and oversea's SGR products are different from their own specific characteristics. This study on the ground protection relay 6.6KV power supply system is focused to protect human.

Characteristics Related to Domestic Accidents of the Elderly (노인의 주택내 사고발생에 영향을 미치는 요인에 관한 연구)

  • Kwak, In-Suk
    • Journal of Families and Better Life
    • /
    • v.27 no.4
    • /
    • pp.55-66
    • /
    • 2009
  • Nearly a half of the accidents the old people had take place in home. Home safety will be more important than ever in rapidly increasing old aged in Korea. The purpose of this paper is to search the general characteristics of domestic accidents related to living environment of the old people experienced. The number of 248 respondents who had experienced of housing related accidents since recent 10 years were selected from 500 interviews with 65 years old and over during April 4th-26th, 2008. About a half of respondents had experienced home accidents. The entrance is the most common places the home accidents occurred, followed by bathrooms and stairs. flooring materials and raised floors are the most dangerous spots. Both places and dangerous objects are related each other. The place is also related to the type of dwelling. Slipping and tripping over most frequently happen in home accidents. It is related to the place like slipping in a bathroom or stairs, and tripping over in entrances. Mostly, legs and arms are injured by the home accidents. A safe home facilitates the old to live healthy and independent in their own places. A safe home for the old is a kind of new issues in Korea. Related policies and researches are about to sprout.

Cause Analysis and Improvement Suggestion for Flood Accident in Dorimcheon - Focused on the Tripping and Isolation Accidents (도림천에서 발생한 고립 및 실족사고의 원인분석을 통한 개선방안 도출에 관한 연구)

  • Lee, Kyung-Su;Jeon, Jong-Hyeong;Kim, Tai-Hoon;Kim, Hyunju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.25-36
    • /
    • 2021
  • This study analyzed the causes of flood accidents, such as isolation and lost footing accidents in Dorimcheon, to provide legal and institutional improvements. For cause analysis, Field Investigation, Stakeholder Interview, Report, manual, Law et al. Review, Analysis of water level change characteristics, automatic alarm issuance standard level analysis, and evacuation time according to river control were evaluated. Dorimcheon has the characteristics of a typical urban river, which is disadvantageous in terms of water control. In addition, the risk of flood accidents is high because the section where fatal accidents occur forms sharply curved channels. Tripping and isolation accidents occur in the floodplain watch and evacuation stage, which is the stage before the flood watch and warning is issued. Because floodplain evacuation is issued only when the water level rises to the floodplain, an immediate response according to the rainfall forecast is essential. Furthermore, considering that the rate of water level rise is up to 2.62 cm/min in Sillimgyo 3 and Gwanakdorimgyo, sufficient evacuation time is not secured after the floodplain watch is issued. Considering that fatal accidents occurred 0.46 m below the standard water level for the flood watch, complete control is very important, such as blocking the entry of rivers to prevent accidents. Based on these results, four improvement measures were suggested, and it is expected to contribute to the prevention of Tripping and Isolation Accidents occurring in rivers.

Operating Characteristics of Molded Case Circuit Breakers by Harmonic Currents (고조파 전류에 의한 배선용 차단기 동작 특성)

  • Jeon, Jeong-Chay;Yoo, Jae-Geun;Lee, Sang-Ick
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.68-74
    • /
    • 2006
  • Malfunction and nuisance tripping of molded case circuit breaker(MCCB) caused by harmonic currents have been reported. But no data is available on the behavior of MCCB under harmonic currents. This paper tested the effects of harmonic currents on four common types of MCCB(thermal, thermal magnetic, magnetic and electronic types). Results of experiment detected no nuisance tripping with any of the breakers tested under test currents, included harmonic current, below rated currents. Additionally it was found that varying harmonic loading conditions did not affect manufacturer specified trip times for thermal only and thermal magnetic circuit breakers. However, under overloaded conditions, trip times of the magnetic only circuit breakers were gradually slowed according to increasing of harmonic currents, and it could cause hazardous overheating of cables. So, the use of magnetic only circuit breakers in the place harmonic currents we serious must be avoided.

A Simplified Approach to the Analysis of the Ultimate Compressive Strength of Welded Stiffened Plates (용접된 보강판의 압축 최종 강도의 간이 해석법)

  • C.D. Jang;Seung-Il Seo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.2
    • /
    • pp.141-154
    • /
    • 1993
  • In this paper, a method to calculate the ultimate compressive strength of welded one-sided stiffened plates simply supported along all edges is proposed. At first initial imperfections such as distortions and residual stresses due to welding are predicted by using simplified methods. Then, the collapse modes of the stiffened plate are assumed and collapse loads for each mode are calculated. Among these loads, the lowest value is selected as the ultimate strength of the plate. Collapse modes are assumed as follows ; (1) Overall buckling of the stiffened plate$\rightarrow$Overall collapse due to stiffener bending (2) Local buckling of the plate part$\rightarrow$Local collapse of the plate part$\rightarrow$Overall collapse due to stiffener yielding (3) Local buckling of the plate part$\rightarrow$Overall collapse due to stiffener berthing (4) Local buckling of the plate part$\rightarrow$Local collapse of the plate part$\rightarrow$Overall collapse due to stiffener tripping. The elastic large deflection analysis based on the Rayleigh-Ritz method is carried out, and plastic analysis assuming hinge lines is also carried out. Collapse load is defined as the cross point of the two analysis curves. This method enables the utimate strength to be calculated with small computing time and a good accuracy. Using the present method, characteristics of the stiffener including torsional rigidity, bending and tripping can also be clarified.

  • PDF

Reynolds Stress Distribution on Boundary Layer Flow Conditions in the Near-Wake of a Flat Plate (평판 근접 후류에서 경계층의 유동조건에 따른 레이놀즈 응력분포)

  • Kim, Dong-Ha;Chang, Jo-Won
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.53-66
    • /
    • 2004
  • An experimental study was carried out in order to investigate the influence of flow conditions on a boundary layer in the near-wake of a flat plate. The flow conditions in the vicinity of the trailing edge that is influenced by upstream condition history are an essential factor that determines the physical characteristics of a near-wake. Tripping wires attached at various positions were selected to change flow conditions of a boundary layer. The flows such as laminar, transitional, and turbulent boundary layer at 0.98C from the leading edge are imposed in order to investigate the evolution of symmetric and asymmetric wake. An x-type hot-wire probe(55P61) is employed to measure at 8 stations in the near-wake. Test results show that the near-wake for the case of a turbulent boundary layer is relatively insensitive to instability after separating at the trailing edge, and Reynolds shear stress in the near-wake for the case of a turbulent boundary layer collapses due to turbulent kinetic energy.

  • PDF

Analysis and Countermeasures for False-Tripping of Earth Leakage Breaker Due to Lightning Surge (누전차단기의 뇌써지 동작특성 분석 및 오동작 대책)

  • Lee, Jae-Bok;Myeong, Seong-Ho;Jo, Yeon-Gyu;Jang, Seok-Hun;Kim, Jeom-Sik
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.479-484
    • /
    • 2002
  • Recently it is reported that many a malfunction of ELB which is represented by non-operated type ELB for an impulse wave, is caused by lightning impulse and transient ground potential rise due to nearby lightning strokes. In order to examine the cause of malfunction, 5 samples were investigated experimentally in this study. As each ELB has a different leakage current detecting circuit and wiring method, various characteristics were measured. As a result, all of them brought about malfunctions under the lightning impulse voltage less than 7 kV and the surge current less than 3 kA. Also the different aspects were measured with a polarity of injected surge and a position of MOV to protect the inner circuit of ELB. The Position and effects of protecting devices were suggested as a remedy.

A Study on the Operating Characteristics of the Aged ELCB according to the Overcurrent (노후화된 누전차단기의 과전류 동작 특성에 관한 연구)

  • Ye Jin Park;Sin Dong Kang;Jae-Ho Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.5
    • /
    • pp.1-7
    • /
    • 2023
  • This study analyzes the operational characteristics of 311 aged and non-aged residual current circuit breakers (RCCBs) in low-voltage consumer contexts. It investigates the influence of external temperature and harmonics based on the rated current multiples. To simulate temperature variations, a convectional oven was used around the circuit breakers. Additionally, the generation of harmonic reference signals and data measurement for overcurrent experiments were conducted using NI SCXI, myDAQ, and LabVIEW. An observation revealed that as the ambient temperature increased, the operating time of RCCBs decreased in the time delay region. This was attributed to the faster response or bending of the bimetal, which is the tripping element. However, aged RCCBs encountered challenges with tripping outside the protective curve. The operating time of the circuit breakers exhibited an acceleration influenced by the order and content of harmonic currents, potentially leading to malfunctions. Aged RCCBs demonstrated faster operating times than their non-aged counterparts. However, the difference in operating time varied based on the manufacturer's and operating environment of the RCCBs. Frequent malfunctions of RCCBs can result in power outages. In cases where these circuit breakers fail to operate, they can lead to secondary damages, including electrical fires and shocks. Consequently, it is imperative to consider the operating environment of RCCBs and provide appropriate replacement cycles to mitigate these risks.

SOME MECHANICAL FACTORS AFFECTING MACHINE MILKING CHARACTERISTICS UNDER SEMI-ARID CONDITION

  • Ali, A.K.A.;Farah, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.5 no.3
    • /
    • pp.475-480
    • /
    • 1992
  • The effect of mechanical factors and season of the year on milking characteristics (milk yield, time of milking, rate of milk flow, stripping time and tripping milk) were studied on 26 Holstein Friesian cows, raised under Saudi Arabia environmental conditions. Cows were in the third and fourth lactation and reached the peak. Cows milked twice a day with equal intervals. Three vacuum levels (34, 38 and 42 cfm) and two pulsation ratios were used to form six vacuum-pulsation combinations. The study was carried during two seasons Autumn-Winter (S1) and Spring-Summer (S2). After absorbing the cow equations least square analysis was used to analyze the data. Vacuum level 38 cfm and pulsation ratio 70:30 was the best among all combinations of vacuum level-pulsation ratio. No significant effect (p < .01) for season, up to the seventh half minute, on the rate of milk flow. However, season of the year has a significant effect on total milk yield, stripping time and stripping milk.

The Gender Difference in the Occupational Hazards and Injuries of Cleaning Workers and Janitors

  • Choi, Chang Lyul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.411-420
    • /
    • 2017
  • Objective: The purpose of this study is to analyze the accident characteristics according to the gender of the injured workers in building cleaning and to reflect them in the Industrial Accident Prevention Policy. Background: An analysis of industrial accidents is an essential process for establishing systematic industrial accident prevention measures. In order to establish industrial accident prevention measures for workers effectively, it is necessary to analyze accident characteristics by job type for workers who do the same work. Method: In this study, we analyzed the accident characteristics of 1,645 janitors who were approved of work-related injuries in 2015. We also analyzed the characteristics according to gender by dividing them into worker-related factors and accident-related factors. Results: The accidents caused to the janitors showed different characteristics according to gender, age, work experience, agency of accident, and distribution of original cause materials. In other words, 70.2% occurred to workers over 60 years old and 56.2% occurred to unskilled workers with less than a year of work experience. In the case of accident pattern, 79.1% occurred in tripping (slip) hazards, and 68.2% of accidents occurred on the floor (including the ground) and the stairs, indicating that the accident occurred most frequently during cleaning work on the floor or stairs. Conclusion and Application: The results of the study on the accident characteristics of the janitors can be used as basic data for systematic preventive measures against accidents occurring to the elderly female workers in the service industry.