• Title/Summary/Keyword: Triple-Mode

Search Result 108, Processing Time 0.03 seconds

A CMOS Rail-to-Rail Current Conveyer and Its Applications to Current-Mode Filters

  • Kurashina, Takashi;Ogawa, Satomi;Watanabe, Kenzo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.755-758
    • /
    • 2002
  • This paper presents a second-generation CMOS current conveyor (CCII) consisting of a rail-to-rail complementary N- and P-channel differential input stage for the voltage input, a class AB push-pull stage for the current input, and current mirrors far the current outputs. The CCII was implemented using a double-poly triple-metal 0.6 ${\mu}$m n-well CMOS process, to confirm its operation experimentally. A prototype chip achieves a rail-to-rail swing ${\pm}$2.4 V under ${\pm}$2.5 V power supplies and shows the exact voltage and current following performances up to 100 MHz. Because of its high performances, the CCII proposed herein is quite useful for a building block of current-mode circuits. The applications of the proposed CCII to current-mode filters are also described.

  • PDF

Torsional Vibration Analysis of Multiple Steped Gear System Using Transfer Matrix Method (전달행렬법을 이용한 다단 치차계의 비틀림 진동 해석)

  • 이형우;박노길
    • Journal of KSNVE
    • /
    • v.8 no.3
    • /
    • pp.504-512
    • /
    • 1998
  • For analyzing the torsional vibration of a multiple stepped gear system containing a pair of triple gears, a transfer matrix model based on Hibner's branch method is developed and the natural properties of the branched rotor system are calculated with using the $\lambda$-matrix formulation. A Campbell diagram, in which the excitation sources caused by the mass unbalances of the rotors and the transmitted errors of thegearings are considered, shows that, at the neighborhood of the operating speed, there are the four critical speeds amplifying the first mode and the fifth mode. For the surpression of the gear box vibration, two ways are suggested by referring the mode shapes.

  • PDF

Design of a 10 bit Low-power current-mode CMOS A/D converter with Current predictors (전류예측기를 이용한 10비트 저전력 전류구동 CMOS A/D 변환기 설계)

  • 심성훈;권용복;윤광섭
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.22-29
    • /
    • 1998
  • In this paper, an 10 bit current-mode CMOS A/D converter with a current predictor is designed with a CMOS process to be integrated into a portable image signal processing system. A current predictor let the number of comparator reduce to 70 percent compared with the two step flash architecture. The current magnitude of current reference is reduced to 68 percent with a modular current reference. The designed 10 bit Low-power current-mode CMOS A/D converter with a current predictor is simulated with HSPICE using 0.6$\mu\textrm{m}$ N-well single-poly triple-metal CMOS process parameters. It results in a conversion rate of 10MSamples/s. A power consumption is measured to be 94.4mW at single +5V supply voltage. The 10 bit A/D converter fabricated using the same process occupies the chip area of 1.8mm x 2.4mm.

  • PDF

Seamless Mode Transfer of Utility Interactive Inverters Based on Indirect Current Control

  • Lim, Kyungbae;Song, Injong;Choi, Jaeho;Yoo, Hyeong-Jun;Kim, Hak-Man
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.254-264
    • /
    • 2019
  • This paper proposes an indirect current control technique based on a proportional resonant (PR) approach for the seamless mode transfer of utility interactive inverters. Direct-current and voltage hybrid control methods have been used for inverter control under grid-connected and islanded modes. A large bandwidth can be selected due to the structure of single-loop control. However, this results in poor dynamic transients due to sudden changes of the controller during mode changes. Therefore, inverter control based on indirect current is proposed to improve the dynamic transients by consistently controlling the output voltage under all of the operation modes. A PR-based indirect current control topology is used in this study to maintain the load voltage quality under all of the modes. The design processes of the PR-based triple loop are analyzed in detail while considering the system stability and dynamic transients. The mode transfer techniques are described in detail for both sudden unintentional islanding and islanded mode voltage quality improvements. In addition, they are described using the proposed indirect control structure. The proposed method is verified by the PSiM simulations and laboratory-scale VDER-HILS experiments.

Simultaneous determination and difference evaluation of 14 ginsenosides in Panax ginseng roots cultivated in different areas and ages by high-performance liquid chromatography coupled with triple quadrupole mass spectrometer in the multiple reaction-monitoring mode combined with multivariate statistical analysis

  • Xiu, Yang;Li, Xue;Sun, Xiuli;Xiao, Dan;Miao, Rui;Zhao, Huanxi;Liu, Shuying
    • Journal of Ginseng Research
    • /
    • v.43 no.4
    • /
    • pp.508-516
    • /
    • 2019
  • Background: Ginsenosides are not only the principal bioactive components but also the important indexes to the quality assessment of Panax ginseng Meyer. Their contents in cultivated ginseng vary with the growth environment and age. The present study aimed at evaluating the significant difference between 36 cultivated ginseng of different cultivation areas and ages based on the simultaneously determined contents of 14 ginsenosides. Methods: A high-performance liquid chromatography (HPLC) coupled with triple quadrupole mass spectrometer (MS) method was developed and used in the multiple reaction-monitoring (MRM) mode (HPLC-MRM/MS) for the quantitative analysis of ginsenosides. Multivariate statistical analysis, such as principal component analysis and partial least squares-discriminant analysis, was applied to discriminate ginseng samples of various cultivation areas and ages and to discover the differentially accumulated ginsenoside markers. Results: The developed HPLC-MRM/MS method was validated to be precise, accurate, stable, sensitive, and repeatable for the simultaneous determination of 14 ginsenosides. It was found that the 3- and 5-yr-old ginseng samples were differentiated distinctly by all means of multivariate statistical analysis, whereas the 4-yr-old samples exhibited similarity to either 3- or 5-yr-old samples in the contents of ginsenosides. Among the 14 detected ginsenosides, Rg1, Rb1, Rb2, Rc, 20(S)-Rf, 20(S)-Rh1, and Rb3 were identified as potential markers for the differentiation of cultivation ages. In addition, the 5-yr-old samples were able to be classified in cultivation area based on the contents of ginsenosides, whereas the 3- and 4-yr-old samples showed little differences in cultivation area. Conclusion: This study demonstrated that the HPLC-MRM/MS method combined with multivariate statistical analysis provides deep insight into the accumulation characteristics of ginsenosides and could be used to differentiate ginseng that are cultivated in different areas and ages.

Design of a Tripple-Mode DC-DC Buck Converter (3중 모드 DC-DC 벅 변환기 설계)

  • Yu, Seong-Mok;Park, Joon-Ho;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.134-142
    • /
    • 2011
  • This paper describes a tripple-mode high-efficiency DC-DC buck converter. The DC-DC buck converter operate in PWM(Pulse Width Modulation) mode at moderate to heavy loads(100mA~500mA), in PFM(Pulse Frequency Modulation)at light loads(1mA~100mA), and in LDO(Low Drop Out) mode at the sleep mode(<1mA). In PFM mode DPSS(Dynamic Partial Shutdown Strategy) is also employed to increase the efficiency at light loads. The triple-mode converter can thus achieve high efficiencies over wide load current range. The proposed DC-DC converter is designed in a CMOS 0.18um technology. It has a maximum power efficiency of 96.4% and maximum output current of 500mA. The input and output voltages are 3.3V and 2.5V, respectively. The chip size is 1.15mm ${\times}$ 1.10mm including pads.

An Efficient Hardware Architecture of Intra Prediction and TQ/IQIT Module for H.264 Encoder

  • Suh, Ki-Bum;Park, Seong-Mo;Cho, Han-Jin
    • ETRI Journal
    • /
    • v.27 no.5
    • /
    • pp.511-524
    • /
    • 2005
  • In this paper, we propose a novel hardware architecture for an intra-prediction, integer transform, quantization, inverse integer transform, inverse quantization, and mode decision module for the macroblock engine of a new video coding standard, H.264. To reduce the cycle of intra prediction, transform/quantization, and inverse quantization/inverse transform of H.264, a reduction method for cycle overhead in the case of I16MB mode is proposed. This method can process one macroblock for 927 cycles for all cases of macroblock type by processing $4{\times}4$ Hadamard transform and quantization during $16{\times}16$ prediction. This module was designed using Verilog Hardware Description Language (HDL) and operates with a 54 MHz clock using the Hynix $0.35 {\mu}m$ TLM (triple layer metal) library.

  • PDF

Finite element modeling of the vibrational behavior of multi-walled nested silicon-carbide and carbon nanotubes

  • Nikkar, Abed;Rouhi, Saeed;Ansari, Reza
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.329-337
    • /
    • 2017
  • This study concerns the vibrational behavior of multi-walled nested silicon-carbide and carbon nanotubes using the finite element method. The beam elements are used to model the carbon-carbon and silicon-carbon bonds. Besides, spring elements are employed to simulate the van der Waals interactions between walls. The effects of nanotube arrangement, number of walls, geometrical parameters and boundary conditions on the frequencies of nested silicon-carbide and carbon nanotubes are investigated. It is shown that the double-walled nanotubes have larger frequencies than triple-walled nanotubes. Besides, replacing silicon carbide layers with carbon layers leads to increasing the frequencies of nested silicon-carbide and carbon nanotubes. Comparing the first ten mode shapes of nested nanotubes, it is observed that the mode shapes of armchair and zigzag nanotubes are almost the same.

Vibration of mitred and smooth pipe bends and their components

  • Redekop, D.;Chang, D.
    • Structural Engineering and Mechanics
    • /
    • v.33 no.6
    • /
    • pp.747-763
    • /
    • 2009
  • In this work, the linear vibration characteristics of $90^{\circ}$ pipe bends and their cylindrical and toroidal shell components are studied. The finite element method, based on shear-deformation shell elements, is used to carry out a vibration analysis of metallic multiple $90^{\circ}$ mitred pipe bends. Single, double, and triple mitred bends are considered, as well as a smooth bend. Sample natural frequencies and mode shapes are given. To validate the procedure, comparison of the natural frequencies is made with existing results for cylindrical and toroidal shells. The influence of the multiplicity of the bend, the boundary conditions, and the various geometric parameters on the natural frequency is described. The differential quadrature method, based on classical shell theory, is used to study the vibration of components of these bends. Regression formulas are derived for cylindrical shells (straight pipes) with one or two oblique edges, and for sectorial toroidal shells (curved pipes, pipe elbows). Two types of support are considered for each case. The results given provide information about the vibration characteristics of pipe bends over a wide range of the geometric parameters.

Vibration performance of composite steel-bar truss slab with steel girder

  • Liu, Jiepeng;Cao, Liang;Chen, Y. Frank
    • Steel and Composite Structures
    • /
    • v.30 no.6
    • /
    • pp.577-589
    • /
    • 2019
  • In this study, on-site testing was carried out to investigate the vibration performance of a composite steel-bar truss slab with steel girder system. Ambient vibration was performed to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes). The composite floor possesses low frequency (< 10 Hz) and damping (< 2%). Based on experimental, theoretical, and numerical analyses on natural frequencies and mode shapes, the boundary condition of SCSC (i.e., two opposite edges simply-supported and the other two edges clamped) is deemed more reasonable for the composite floor. Walking excitations by one person (single excitation), two persons (dual excitation), and three persons (triple excitation) were considered to evaluate the vibration serviceability of the composite floor. The measured acceleration results show a satisfactory vibration perceptibility. For design convenience and safety, a crest factor ${\beta}_{rp}$ describing the ratio of peak acceleration to root-mean-square acceleration induced from the walking excitations is proposed. The comparisons of the modal parameters determined by ambient vibration and walking tests reveal the interaction effect between the human excitation and the composite floor.