• Title/Summary/Keyword: Triple detectors

Search Result 4, Processing Time 0.018 seconds

A Study on Development of an Electromagnetic Inductive Sensor for Automatic Weld Seam Tracking (용접선 자동추적용 전자기유도센서의 개발에 관한 연구)

  • Bae Kang-Yul
    • Journal of Welding and Joining
    • /
    • v.23 no.4
    • /
    • pp.66-72
    • /
    • 2005
  • An electromagnetic inductive sensor consisted of one exciter and three separated (triple) detectors has been developed for both tracking the weld seam of a workpiece and controlling the sensor-to-workpiece distance (height) simultaneously. The left and right detectors are used to track the seam, while the fore and the other two detectors allow the sensor to determine the height and the gap width by being coupled their outputs together. A series of experiments with the proposed sensor located above a mild steel plate containing a weld seam of gap are carried out to examine the feasibility of the sensor. The results revealed that the proposed sensor could fairly well track the desired seam and also well control the height to be constant even when the gap width of the seam varied. The gap width can be also determined during the seam tracking by using the sensor outputs. As a consequence, these can provide the developed sensor with substantial improvement for industrial uses with respect to the previous electromagnetic sensors being used for the weld seam tracking.

A Novel Corner Detector using a Non-cornerness Measure

  • Park, Seokmok;Cho, Woon;Paik, Joonki
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.6 no.4
    • /
    • pp.253-261
    • /
    • 2017
  • In this paper, a corner detection method based on a new non-cornerness measure is presented. Rather than evaluating local gradients or surface curvatures, as done in previous approaches, a non-cornerness function is developed that can identify stable corners by testing an image region against a set of desirable corner criteria. The non-cornerness function is comprised of two steps: 1) eliminate any pixel located in a flat region and 2) remove any pixel that is positioned along an edge in any orientation. A pixel that passes the non-cornerness test is considered a reliable corner. The proposed method also adopts the idea of non-maximum suppression to remove multiple corners from the results of the non-cornerness function. The proposed method is compared with previous popular methods and is tested with an artificial test image covering several corner forms and three real-world images that are universally used by the community to evaluate the accuracy of corner detectors. The experimental results show that the proposed method outperforms previous corner detectors with respect to accuracy, and that it is suitable for real-time processing.

Kinetic Studies on Homopolymerization of $\alpha$-Methylstyrene and Sequential Block Copolymerization of Isobutylene with $\alpha$-Methylstyrene by Living/Controlled Cationic Polymerization (리빙/조절 양이온중합에 의한 알파메틸스티렌 호모중합 및 이소부틸렌과의 블록공중합에 대한 반응속도론 연구)

  • Wu, Yibo;Guo, Wenli;Li, Shuxin;Gong, Huiqing
    • Polymer(Korea)
    • /
    • v.32 no.4
    • /
    • pp.366-371
    • /
    • 2008
  • The controlled/living cationic polymerization of $\alpha$-methylstyrene (${\alpha}MeSt$) and sequential block copolymerization of isobutylene (IB) with ${\alpha}MeSt$ were achieved using 2-chloro-2,4,4-trimethylpentane (TMPCl)/titanium tetrachloride ($TiCl_4$)/titanium isopropoxide ($Ti(OiPr)_4$)/2,6-ditert-butylpyridine (DtBP) initiating system in $CH_3Cl$/hexane(50/50 v/v) solvent mixture at $-80^{\circ}C$. The polymerization rate decreased with increasing $[Ti(OiPr)_4]/[TiCl_4]$ ratio in the homopolymerization of ${\alpha}MeSt$. The effects of $[Ti(OiPr)_4]/[TiCl_4]$ ratios and $PIB^+$ molecular weight on the polymerization rate and blocking efficiency were also investigated. Well-defined poly(isobutylene-b-$\alpha$-methylstyrene)s were demonstrated by $^1H$-NMR and triple detection SEC; refractive index (RI), multiangle laser light scattering (MALLS) and ultraviolet (UV) detectors. Blocking efficiencies for the poly(isobutylene-b-$\alpha$-methylstyrene)s of almost 100% were obtained when ${\alpha}MeSt$ was induced by PIB's of $M_n\;{\geq}\;41000$ at $[Ti(OiPr)_4]/[TiCl_4]=1$. Differential scanning calorimetry (DSC) of the block copolymers showed two glass transition temperatures, thereby demonstrating microphase separation.

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.