• 제목/요약/키워드: Trip wire

검색결과 8건 처리시간 0.024초

자유류 난류와 표면 트립 와이어가 구 주위 유동에 미치는 영향 (Effects of the Free-Stream Turbulence and Surface Trip Wire on the Flow past a Sphere)

  • 손광민;최진;전우평;최해천
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.187-190
    • /
    • 2006
  • In the present study, effects of tree-stream turbulence and surface trip wire on the flow past a sphere at $Re\;=\;0.4\;{\times}\;10^5\;{\sim}\;2.8\;{\times}\;10^5$ are investigated through wind tunnel experiments. Various types of grids are installed upstream of the sphere in order to change the tree-stream turbulence intensity. In the case of surface trip wire, 0.5mm and 2mm trip wires are attached from $20^{\circ}\;{\sim}\;90^{\circ}$ at $10^{\circ}$ interval along the streamwise direction. To investigate the flow around a sphere, drag measurement using a load cell, surface-pressure measurement, surface visualization using oil-flow pattern and near-wall velocity measurement using an I-type hot-wire probe are conducted. In the variation of free-stream turbulence, the critical Reynolds number decreases and drag crisis occurs earlier with increasing turbulence intensity. With increasing Reynolds number, the laminar separation point moves downstream, but the reattachment point after laminar separation and the main separation point are fixed, resulting in constant drag coefficient at each free-stream turbulence intensity. At the supercritical regime, as Reynolds number is further increased, the separation bubble is regressed but the reattachment and the main separation points are fixed. In the case of surface trip wire directly disturbing the boundary layer flow, the critical Reynolds number decreases further with trip wire located more downstream. However, the drag coefficient after drag crisis remains constant irrespective of the trip location.

  • PDF

마이크로 방전가공에서 Round Trip Method를 이용한 전극마모 보정 (Tool Electrode Wear Compensation using Round Trip Method for Machining Cavities in Micro EDM Process)

  • 박성준;김영태;민병권;이상조
    • 한국정밀공학회지
    • /
    • 제21권10호
    • /
    • pp.42-49
    • /
    • 2004
  • Electrical discharge machining (EDM) is one of the most extensively used non-conventional material removal process. The recent trend in reducing the size of product has given micro EDM a significant amount of research attention. Micro EDM is capable of machining not only micro holes and micro shafts as small as a few micrometers in diameter but also complex three dimensional micro cavities. But, longitudinal tool wear by electrical discharge is indispensable and this affects the machining accuracy in micro EDM process. Therefore, newly developed tool wear compensation strategy called round trip method is suggested and verified by experiment. In this method, machining depth of cut, overlap effect and critical travel length are also considered.

4극 저압차단기 N상 Trip장치를 사용한 영상고조파 안전성 개선방안 (Safely Improving Method to Zero-Harmonics Current with 4-Pole Low Voltage Circuit Breaker Equipped N-phase Trip Device)

  • 기채옥;김주철;최창규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.458-461
    • /
    • 2009
  • 3상 4선식 배전방식에서 비선형 부하증가로 인한 제 3고조파 전류발생은 선로의 중성선 및 기기를 과열시키는 원인으로 작용하고 있다. 따라서 고조파에 의한 역률저하 및 기기, 선로 등을 안전하게 보호할 필요가 있다. 본 논문에서는 제 3고조파 전류로 인한 사고사례를 조사하고 고조파 분석 및 부하 불평형 등을 분석하였다. 이를 통해 가장 경제적인 4극 저압차단기를 사용하여 중성선의 과전류로부터 선로 및 기기를 보호하는 방법을 제시하였다.

  • PDF

무선통신시스템 활용을 위한 원자력발전소 EMC 확보방안에 관한 연구 (A Study on the EMC for Application of Wireless Communication System in Nuclear Power Plants)

  • 고도영;배병환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.500-502
    • /
    • 2006
  • Recently, nuclear power plants have been testing for application of wireless communication system to improve communication easier. Improving the availability of communication in NPPs, plant operation ability and good communication have contributed to the lower reactior trip frequency. In these regards, the possibilities of improvement in communication systems are reviewed detail. Especially, we reviewed the wire communication system, facility effect, regulation and new technologies. In this paper, we described the application of wireless in NPPs by studying EMI/RFI, EMC effect.

  • PDF

옥내 배선계통에서 직렬 아크의 검출과 판별 (Detection and Identification of the Series Arc in an Indoor Wiring System)

  • 김우현;왕국명;길경석;지홍근
    • 한국전기전자재료학회논문지
    • /
    • 제31권6호
    • /
    • pp.412-416
    • /
    • 2018
  • Most series arcs lead to electrical fires that cannot be interrupted by circuit breakers, because the arc's current is outside the breaker's operating range. In this paper, experiments were conducted on the detection and identification of series arcs to prevent electrical fires. Plugs and outlets specified in KS C 8305 were deteriorated to replicate arc faults commonly found in fields. The characteristics of series arcs resulting from various types of loose connections were determined by analyzing the frequency spectra and phase distributions of detected arc pulses. The results showed that the simulated arc defects used in this study were more similar to actual arc phenomena than the existing arc generator specified in UL 1699. In addition, loose connections, such as wire-wire, terminal-wire, and outlet-plug, can be identified by phases of $0^{\circ}$, $180^{\circ}$ and $360^{\circ}$, respectively. These phases can be detected by a band pass filter with a frequency range of 5~10 MHz, which can be used as the trip signal for circuit breakers.

Performance Issues with General Packet Radio Service

  • Chakravorty, Rajiv;Pratt, Ian
    • Journal of Communications and Networks
    • /
    • 제4권4호
    • /
    • pp.266-281
    • /
    • 2002
  • The General Packet Radio Service (GPRS) is being deployed by GSM network operators world-wide, and promises to provide users with “always-on” data access at bandwidths comparable to that of conventional fixed-wire telephone modems. However, many users have found the reality to be rather different, experiencing very disappointing performance when, for example, browsing the web over GPRS. In this paper, we examine the causes, and show how unfortunate interactions between the GPRS link characteristics and TCP/IP protocols lead to poor performance. A performance characterization of the GPRS link-layer is presented, determined through extensive measurements taken over production networks. We present measurements of packet loss rates, bandwidth availability, link stability, and round-trip time. The effect these characteristics have on TCP behavior are examined, demonstrating how they can result in poor link utilization, excessive packet queueing, and slow recovery from packet losses. Further, we show that the HTTP protocol can compound these issues, leading to dire WWW performance. We go on to show how the use of a transparent proxy interposed near the wired-wireless border can be used to alleviate many of these performance issues without requiring changes to either client or server end systems.

Evaluation of Critical Current Density of FeAs-based Superconductors

  • Otabe, Edmund S.;Kiuchi, Masaru;Matsushita, Teruo;Ni, Baorong;Qi, Yanpeng;Wang, Lei;Gao, Zhaoshun;Wang, Dongliang;Zhang, Xianping;Ma, Yanwei;Nakajima, Yasuyuki;Tamegai, Tsuyoshi
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권2호
    • /
    • pp.1-7
    • /
    • 2012
  • In this review paper, we report the characteristics of the critical current density in FeAs based superconductors which is newly discovered by Hosono group of Tokyo Institute of Technology on 2008. Since the many specimens in present stage are not single crystals, there are two kinds of critical current density observed in the specimens which are so-called local and global critical current densities. Therefore, it is necessary to evaluate both kinds of critical current densities. The history effect in which the global critical current density shows different values in increasing and decreasing magnetic field is also observed when the specimens have the local and the global critical current densities. The wire which critical current is 180 A is successfully developed with using the knowledge of abovementioned characteristics of two kinds of critical current densities and the history effect.

Dynamic PIV를 이용한 난류경계층 내부 와구조 거동의 실험적 분석 (Experimental analysis of vortical structures in a turbulent layer using a dynamic PIV technique)

  • 최용석;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.193-196
    • /
    • 2008
  • The vortical structures in a turbulent boundary layer (TBL) developed over a flat plate have been investigated experimentally. The flow conditions tested in this study were Re$_{\theta}$ = 3700, Re$_{\delta}$ = 11${\times}$105 and the shape factor H = 1.3. Instantaneous velocity fields in the streamwise-wall-normal planes were measured by using a dynamic PIV system. A trip-wire and sandpapers were placed behind the leading edge to promote the turbulent transition. 1000 velocity fields were obtained consecutively with a time interval of 1 millisecond. Streamwise u-velocity components were temporally averaged in the measuring plane. In addition, 2000 velocity fields were obtained randomly and ensemble-averaged to get the fully-developed turbulent characteristics. Profiles of the normalized u-component, turbulent intensities and Reynolds shear stress were evaluated. The structures of spanwise vortices were extracted from the instantaneous velocity fields by determining the swirling strength, ${\lambda}_{ci}$. The wall-normalized locations of vortices were temporally averaged in the measuring plane with respect to their rotational direction. The correlations between the temporally averaged u and the temporally averaged $y^+$ of vortices were evaluated. For the case of positive vortices, the correlation is not significant. However, the negative vortices show a strong negative correlation. The y-location of negative vortices tends to increase, as the averaged u decreases and vice versa. These findings indicate that the number of negative vortices in the outer layer increases during the outward bursting events.

  • PDF