• Title/Summary/Keyword: Trip hammer

Search Result 3, Processing Time 0.015 seconds

Hammer Energy Level of SPT in Korea (표준관입시험의 해머에너지 수준)

  • 이호준;박용원
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.117-126
    • /
    • 1996
  • In spite of many advantages such as the simplicity in test procedure, Standard Penetration Test(SPT) results contain some errors caused by the variability of test equipment, instruments and test procedures. Especially, it is inevitable that the measured SPT hammer energy is different from the theoretical value because of energy loss. In this paper, the hammer energy level is measured during the performance of the field SPT in Korea by using a ultra-sonic system and PC.program. As the results of this study, the average hammer energy ratio of the R-P hammer and the Trip hammer is calculated at 64.2%, and at 75.0% respectively. The average energy ratio of the SPT for the R-P hammer is calculated at 46% and at 54% for the Trip hammer, by applying the rod energy ratio 0.72.

  • PDF

Rod Energy Ratio Measurement of SPT (표준관입시험의 동적효율 측정)

  • Lee, Ho-Chun;Kim, Byeong-Il;Park, Yong-Won
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.169-182
    • /
    • 1997
  • It is known that some amount of loss in impact energy takes place due to some limitations and problems during the performance of the field SPT. Actual energy level tractsferred to the rod should be measured to correct the SPT-N values tested in the field In this paper, the ratio of energy transferred to the rod through the anvil to impact energy is measured by using sharpy impact test equipment and also analysed by using GRL-WEAP This result is certified and compared with that of field SPT As the results of this study, the average rod energy ratio of the R-P hammer and the Trip hammer is calculated at 0.726 and 0.728 respectively, but it is suggested that 0.72 should be used. By using the hammer energy ratio 64.2% and 75.0% obtained from field measurement, the average energy ratio of the SPT for the R-P hammer is calculated at 46.7% and 54.5% for the Trip hammer.

  • PDF

The Hammer Energy Delivered to the Drilling Rod in the SPT 1 (표준관입시험시 롯드에 전달되는 해머의 낙하에너지 평가 1)

  • 조성민;정종홍;김동수;이우진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.469-476
    • /
    • 2001
  • The Ν-value in the standard penetration test(SPT) is affected by the magnitude of the rod penetration energy transmitted from the falling hammer as well as the geotechnical characteristics of the ground. Understanding of the striking energy efficiency in the SPT equipment is getting important for that reason. The energy efficiencies of the doughnut hammer with the hydraulic lift system and the automatic trip hammer system were investigated through field tests using the instrumented rod and wave-signal acquisition systems including the pile driving analyzer(PDA) . The rod energy ratio, ΕR$\_$r/ was defined as the ratio of the energy delivered to the drilling rod to the potential free-fall energy of the hammer. It appears that the type of the hammer and lift/drop system had a strong influence on the energy transfer mechanism and ΕR$\_$r/ also varies according to the energy instrumentation system and the analysis methods.

  • PDF