• Title/Summary/Keyword: Trip Line

검색결과 117건 처리시간 0.024초

Modified Transmission Line Protection Scheme in the Presence of SCC

  • Naeini, Ehsan Mostaghimi;Vaseghi, Behrouz;Mahdavian, Mehdi
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.533-540
    • /
    • 2017
  • Distance relay identifies the type and location of fault by measuring the transmission line impedance. However any other factors that cause miss calculating the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of the important factors which directly changes the measured impedance by the relay is series capacitive compensation (SCC). Another factor that changes the calculated impedance by distance relay is fault resistance. This paper provides a method based on the combination of distance and differential protection. At first, faulty transmission line is detected according to the current data of buses. After that the fault location is calculated using the proposed algorithm on the transmission line. This algorithm is based on active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. This method measures the voltage across SCC by phasor measurement units (PMUs) and transmits them to the relay location via communication channels. The transmitted signals are utilized to modify the voltage signal which is measured by the relay. Different operating modes of SCC and as well as different faults such as phase-to-phase and phase-to-ground faults are examined by simulations.

뇌사고율 저감을 위한 154 kV 송전선의 차등절연 적용 방안 연구 (A study on the Unbalanced Insulation of the Double Circuit 154 kV Transmission Lines to Reduce Lightning Failure Rate)

  • 곽주식;강연욱;우정욱;심응보;김우겸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.151-159
    • /
    • 2003
  • According to the records, approximately 50 percent of power failure were caused by lightning. Conventional fault preventive measures against lightning include reduction of the footing resistance of the tower, multiplication of overhead ground wires and unbalanced insulation of the double circuit transmission tower. In addition to these, transmission line arresters have been recently appeared as an alternatives. In this paper an unbalanced insulation method with transmission line arrester was assumed as another countermeasure against simultaneous double circuit trip of 154 kV transmission line by lightning strike. The lightning performance of line arrester was compared with conventional insulation concept using different numbers of porcelain and glass insulator. Larger numbers of insulator simply increase flashover current level by lightning but the lightning performance doesn't proportional to it. EMTP simulation and predictive calculation of lightning failure rate were carried out to evaluate the performance.

  • PDF

Phenomena Identification and Ranking Table for the APR-1400 Main Steam Line Break

  • Song, J.H.;Chung, B.D.;Jeong, J.J.;Baek, W.P.;Lee, S.Y.;Choi, C.J.;Lee, C.S.;Lee, S.J.;Um, K.S.;Kim, H.G.;Bang, Y.S.
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.388-402
    • /
    • 2004
  • A phenomena identification and ranking table(PIRT) was developed for a main steam line break (MSLB) event for the Advanced Power Reactor-1400 (APR-1400). The selectee event was a double-ended steam line break at full power, with the reactor coolant pump running. The developmental panel selected the fuel performance as the primary safety criterion during the ranking process. The plant design data, the results of the APR-1400 safety analysis, and the results of an additional best-estimate analysis by the MARS computer code were used in the development of the PIRT. The period of the transient was composed of three phases: pre-trip, rapid cool-down, and safety injection. Based on the relative importance to the primary evaluation criterion, the ranking of each system, component, and phenomenon/process was performed for each time phase. Finally, the knowledge-level for each important process for certain components was ranked in terms of existing knowledge. The PIRT can be used as a guide for planning cost-effective experimental programs and for code development efforts, especially for the quantification of those processes and/or phenomena that are highly important, but not well understood.

ISO 2631-1을 이용한 국내 고속철도차량의 인체진동 노출량 평가 (Evaluation of Human Exposure to Vibration on Domestic High-speed Train using ISO 2631-1)

  • 김지만;박진한;안세진;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제25권4호
    • /
    • pp.266-274
    • /
    • 2015
  • Vibration exposure of domestic high speed trains(KTX and ITX-saemaeulho) to passenger traveling on the Gyung-Bu line was measured to evaluate health effect which is based on ISO 2631-1. The vibration exposure was compared with the frequency weighted root mean square(r.m.s.) and vibration dose value(VDV) of the two trains’ vibration. It is concluded that vibration exposure of the two train during round trip of Busan-Seoul in single day is evaluated to be safe for the passenger’s health according to the health guidance caution defined on ISO 2631-1. Futhermore KTX’s vibration exposure is found to be significantly lower than ITX-saemaeulho thanks to lower vibration magnitude as well as shorter trip time.

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

용접 판재의 U 드로오 벤딩에서 스프링백 예측을 위한 이론적 단순화 (A Simplified Approach for Predicting Springback in U-Draw Bending of Sheet Metals)

  • 장성호;서대교
    • 소성∙가공
    • /
    • 제13권8호
    • /
    • pp.678-688
    • /
    • 2004
  • The U-draw bending operation is known as a representative test method for springback evaluation of sheet metals since the sheet in U-draw bending operation undergoes stretching, bending and unbending deformations occurred at the stamping process. In this study, a simplified approach was proposed for predicting springback and side-wall curls of tailor-welded blank in U-draw bending operations, using moment-curvature relationships derived for sheets undergoing stretching, bending and unbending deformation. Two different welded strips were adopted to compare the effects of weld-line locations on the springback. One (type A) was welded along the centerline of the strip-width and the other (type B) was welded along the centerline of the strip-length. To investigate the effect of different thickness combination on the springback, the tailor-welded strips were joined by the laser welding process and consisted of three types of thickness combinations of sheets, SCP1 0.8t * SCP1 1.2t, SCP1 0.8t * SCP1 1.6t and SCP1 0.8t * TRIP 1.0t. Some calculated results by the simplified formula were compared with experimental results.

TRIP강에서 박막 깊이의 Mg 함량의 변화에 따른 밀착력에 관한 연구 (Improved Adhesion Strength of the Gradient Zn-Mg Coating on TRIP Steel)

  • 송면규;김회근;이상율
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.136-136
    • /
    • 2018
  • 듀얼 페이즈(DP) 강철과 같은 고강도강(HSS), TRIP강, TWIP강은 무게를 줄이고 자동차의 안전을 향상시키기 위해서 자동차 산업에서 광범위하게 쓰이고 있다. HSS강의 내부식성을 향상시키기 위해서, 향상된 박막 재료와 기존의 아연도금 공정을 대체하는 공정 방법이 필요하다. Zn-Mg 박막은 강의 부식 방지에 대한 강력한 후보이며, 물리적 기상 증착 공정(PVD)은 강의 Zn-Mg 박막의 증착을 위한 유망한 공정이다. 그러나 이전 연구에서 보고 된 바와 같이 Zn-Mg 박막은 Zn-Mg 박막의 높은 취성으로 인하여 Zn 박막에 비하여 접착력이 매우 불충분하였다. 따라서 본 연구에서는 Zn-Mg 박막의 첩착력을 향상시키기 위해 TRIP강 기판 위에 증발 증착법을 활용하여 Zn-Mg/Zn 이중층 박막을 합성하고 진공에서 열처리를 실시하여 박막의 깊이에 따른 Mg의 함량 변화를 유도하였다. Zn-Mg/Zn 박막 합성 시 EMH-PVD를 활용하여 증착하였으며, Zn 중간층을 모재와 Zn-Mg 층 사이에 증착하고 진공중에서 열처리를 실시하여 박막 내에서 Mg 함량의 기울기 변화가 박막의 밀착력에 주는 영향을 평가하였다. 증착된 박막은 FE-SEM을 통하여 미세조직과 박막의 두께를 분석하였고 line-EDS를 통하여 깊이에 따른 Zn와 Mg의 변화를 분석하였으며 XRD를 사용하여 합금상을 분석하였다. Lap shear test를 활용하여 박막의 밀착력을 정략적으로 분석하였다. FE-SEM 및 EDS 분석 결과 Zn-Mg/Zn 박막을 진공에서 열처리를 실시한 후 FE-SEM으로 분석한 결과 미세조직의 큰 차이는 보이지 않았으나, line-EDS 결과 Mg이 확산되는 것을 확인 할 수 있었다. XRD 분석 결과 확산한 Mg에 의해서 Zn상은 감소하고 $Mg_2Zn_{11}$, $MgZn_2$와 같은 합금상은 증가하는 것을 확인하였다. Lap shear test 결과 $200^{\circ}C$에서 열처리한 Zn-15wt.%Mg/Zn 박막의 경우 밀착력이 19 MPa로 열처리를 하지 않았을 경우(11 MPa)보다 향상되는 것을 확인하였다. 이러한 결과는 통하여 Zn-Mg 박막의 두께의 Mg의 함량 변화에 의해서 박막의 밀착력이 변화되는 것을 알 수 있다.

  • PDF

IGCC 온라인 성능계산 모듈 (On-line Performance Calculation Module of IGCC Power Plant)

  • 주용진;김시문;이민철;정재화
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.364-367
    • /
    • 2008
  • This present paper describes concepts of the real-time operation monitoring system as a tool for enhancing the reliability and raising the availability of the first Korea IGCC (Integrated Gasification Combined Cycle) power plant. This system consists of five (5) modules : (1) Data Validation Module, (2) Performance Calculation Module (3) Performance Diagnostic Module, (4) Trip Information Module, and (5) Statistics Analysis Module. Among these modules, Performance Calculation Module is explained in more detail. The objective of this module is to continuously evaluate the degradation (decrease in performance) of the IGCC plant and its equipment in order to provide plant operators additional information to help them identify problems, improve performance.

  • PDF

Study on Characteristics of Subchannel Analysis Code at Low Flow Steam Line Break Condition

  • Kwon, Hyuk-Sung;Lim, Jong-Seon;Hwang, Dae-Hyun;Chun, Tae-Hyun;Park, Jong-Ryul
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.403-408
    • /
    • 1996
  • The subchannel analysis was performed to verify the behavior of hot channel characteristics and obtain the information to support the core thermal-hydraulic behavior at post-trip steam line break with low flow condition. During this postulated accident, buoyancy-induced cross flow occurs, and the coupled nuclear and thermal-hydraulic interactions become important. The code predictions with TORC are in good agreement with the test data. Under such conditions, the mass flow increase in the hot channel by buoyancy-induced cross flow depends on the parameter $GR^{*}\;/\;Re^2$, and buoyancy effect becomes more noticeable as $GR^{*}\;/\;Re^2$ increases.

  • PDF

철도 부분의 장소 마케팅 도입 가능성 검토 (A Study on the Possibility of Place Marketing in Railway)

  • 이원희
    • 한국철도학회논문집
    • /
    • 제12권6호
    • /
    • pp.915-920
    • /
    • 2009
  • 장소 마케팅이란 특정 장소를 하나의 상품으로 인식하도록 기업과 주민, 관광객이 선호하는 이미지와 제도, 시설 등을 통해 장소의 상품가치를 제고하는 것이다. 이러한 개념을 철도에 적용하여 새로운 지역발전의 전략을 모색할 수 있다. 폐지선과 영업 정지 역을 활용하여 새로운 지역 개발의 기회로 삼는 사례들이 이러한 맥락이다. 나아가 관광, 여가 문화, 지역축제를 철도와 연계할 필요가 있다. 이를 위해서는 지방자치단체와의 협력이 필요하다.