• Title/Summary/Keyword: Trigger mechanism

Search Result 129, Processing Time 0.027 seconds

Optimization ova Mechanism for Power Transfer Breakers (전력변환차단기의 트리거 기구 최적화)

  • 조두현;김권희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.735-739
    • /
    • 2002
  • PTB(Power Transfer Breaker) is a device which incorporate the functions of ACB(Air Circuit Breaker) and ATS(Automatic Transfer Switch). ACB is a circuit breaker against overload and ATS is a switching device to transfer the load between two electric power sources. An existing PTB design based upon the 5 bar & cam mechanism has been regarded to be too complex and thus a simpler 4 bar mechanism with trigger lock is proposed. Experimentation and optimization of the trigger lock is presented.

  • PDF

Design of an power transfer breaker by Taguchi method (다구찌 법을 이용한 전력전환차단기의 설계)

  • Kim, Kyung-Sun;Kim, Kwon-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.810-814
    • /
    • 2001
  • power transfer breaker is a device used to transfer the load from the electricity power line to the emergency generators. In case of overload, it also functions as a circuit breaker. In this work, a new mechanism for the device is suggested. Among the various design challenges, optimization of the trigger mechanism is identified as of central importance. Optimal design decisions are made with the use of Taguchi method.

  • PDF

A Study on Gate Trigger Current of SCR (SCR 게이트 전류의 변화특성에 관한 연구)

  • Seong, Houng-Su;Won, Hak-Jai;Han, Seung-Mun;Ha, Jeong-Hoon;Park, Ho-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1333-1335
    • /
    • 2000
  • In order to turn on the SCR gate, trigger signal source have to provide appropriate gate current and voltage under the gate rating based on the characteristic of SCR, the nature of load and power. It will be essential design factors such as trigger source impedance, trigger signal occurring, signal time width and turn off conditions. Also minimum gate trigger current is changed with the deterioration of SCR. SCR, which is needed large gate trigger current absolutely, is very important for SCR characteristic test because it causes unstable output in the misfile or makes a trouble to pulse trigger circuits. This paper shows scheme to test the performance of SCR with the precision analyzing mechanism and the changing trend of minimum gate current under the trigger conditions.

  • PDF

Axial crush and energy absorption characteristics of Aluminum/GERP hybrid square tube (알루미늄/GFRP 혼성 사각튜브의 정적 압축 붕괴 및 에너지 흡수 특성)

  • 김구현;이정주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.168-171
    • /
    • 1999
  • For the axial crushing tests of various shape of tubes, it was reported that composite tubes need trigger mechanism to avoid brittle failure. In this study, static axial crush tests were performed with the new aluminum/GFRP hybrid tubes. Glass/Epoxy prepregs were wrapped around aluminum tube and co-cured. The failure of hybrid tube was stable and progressive without trigger mechanism, and specific energy absorption was increased to maximum 34% in comparison with aluminum tube. Effective energy absorption is possible for inner aluminum tube because wrapped composite tube constrain the deflection of aluminum tube and reduce the folding length. The failure of hybrid composite tube was stable without trigger mechanism because inner aluminum tube could play the role of crack initiator and controller. Aluminum/Glass-Epoxy hybrid tube is suitable for the vehicle front structure due to effective energy absorption capability, easy production, and simple application for RTM process.

  • PDF

Design of an Automatic Target Sensing and Triggering System (적외선 감지 자동격발장치의 설계)

  • Hong S.H.;Kim K.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1719-1723
    • /
    • 2005
  • An automatic target sensing and triggering system for small fire arms is proposed. The system consists of an optical collector, an infrared ray sensor responsive to human body temperature, an electric actuator and a trigger mechanism. TRIZ methodologies are used to develop solutions to several contradictory problems. Experimental results on the system performance is compared with predictions.

  • PDF

The Effect of Tienchu Acupoint Block, Occipital Nerve Block, and Trigger Point Injection for Treatment of Tension Type Headache (긴장형 두통 환자에서 천주점, 후두신경차단 및 통증유발점주사의 치료효과)

  • Lee, Yong-Woo
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.75-80
    • /
    • 1999
  • Background: Despite tension type headache is popular, the exact mechanism and method of treatment are not certain yet. So, we supposed the basic mechanism of tension type headache is myogenic, and did Tienchu acupoint block, occipital nerve block, and trigger point injection in tension type headache patients. Methods: Fifty-seven tension type headache patients were treated with local anesthetics and small dose of steroid. The intensity of pain and effect of every treatment was evaluated as Verbal Rating Score (VRS; 0~10) before and after every treatment. Evaluation of treatment was based on the time of treatment (1,2 times, 3 times, 4,5 times). Goal of treatment was VRS reaching below two point and it was considered as treated state. Results: Symptom improvement rates of each treatment were 90% (1, 2 times), 91% (3 times), 70% (4, 5 times) respectively. VRS reduction more than 50% rates were 60%, 64%, 60% respectively. Treated state (VRS<2) rates were 33%, 27%, 30% respectively. Conclusion: Tienchu acupoint block, occipital nerve block, trigger point injection were sorts of most effective and simply applicable modalities of treatment in tension type headache.

  • PDF

Axial Crush and Energy Absorption Characteristics of Aluminum/GFRP Hybird Square Tubes (알루미늄/GFRP 혼성 사각튜브의 정적 압축 붕괴 및 에너지 흡수 특성)

  • 김구현;이정주;신금철
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.208-219
    • /
    • 2000
  • In this study, static axial crush tests were performed with the new aluminum/GFRP hybrid tube. Glass/Epoxy prepregs were wrapped around an aluminum tube and co-cured. The failure of the hybrid tube was stable and progressive without trigger mechanism, and specific energy absorption was increased to the maximum of 33% in comparison with the aluminum tube. Effective energy absorption is possible for an inner aluminum tube because a wrapped composite tube constrains the deflection of an aluminum tube. The failure of a hybrid composite tube was stable without trigger mechanism because the inner aluminum tube could play the role of the crack initiator and controller. Mean crushing load could be calculated by modifying the plastic hinge collapse model for hybrid materials. The predicted results by this analytical model showed good agreement with the experimental results. It can be said that Aluminum/Glass-Epoxy hybrid tube is suitable for the vehicle front structure because this hybrid tube shows effective energy absorption, easy production, and simple application capability for RTM process.

  • PDF

A Case Study of Myofascial Trigger Point Syndrome (근막 동통증후군 환자의 4례 -증례보고-)

  • Chung, Nack-Su
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.1
    • /
    • pp.413-422
    • /
    • 1995
  • The trigger point phenomenon is an extremely common syndrome in physical therapy room. The symptoms created by these syndromes may be interpreted as originating in discogneic disease, nerve entrapment syndromes, viscerosomatic pain, and certain myalgic pain of unknown etiology. Injuries, viral or bacterial infections, immobilization, psychogenic stress, and other environment factors can preciptate and perpetuate these syndromes, which may occur in any of the voluntary muscles of the human body and thus lead to a multitude of myofascial pain syndromes. Obviously symptomatic treatment can meet with only partial success. Knowledge of the trigger point phenomenon will aid the diagnostician in understanding otherwise in explicable symptom. The trigger point are $2{\sim}5mm$ in diameter, hyperirritable palpable taut in a tissue, when compressed, is locally tender, if sufficiently hypersensitive, give rise to referred pain and tenderness, and sometimes to referred automatic phenomena and distortion of proprioception. The treatment of myofascial trigger point pain syndrome is not difficult once the source of the problem has been determined. Where as many modalities may be used, two of the most effective are spray-and stretch and TP injection. These can be followed by deep massage, specific, manual resistive exercise, and an exercise program which the patient can follow at home. The goal of management is to inactivate the TPs and to restore shortened and stretch resistent muscles to their full range of motion. The purpose of this case study was to know about the pathophysiologic mechanism of the trigger point and will enable to physical therapist to direct his treatment to the real source of trouble.

  • PDF

Touch-Trigger Probe Error Compensation in a Machining Center (공작기계용 접촉식 측정 프로브의 프로빙 오차 보상에 관한 연구)

  • Lee, Chan-Ho;Lee, Eung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.661-667
    • /
    • 2011
  • Kinematic contact trigger probes are widely used for feature inspection and measurement on coordinate measurement machines (CMMs) and computer numerically controlled (CNC) machine tools. Recently, the probing accuracy has become one of the most important factors in the improvement of product quality, as the accuracy of such machining centers and measuring machines is increasing. Although high-accuracy probes using strain gauge can achieve this requirement, in this paper we study the universal economic kinematic contact probe to prove its probing mechanism and errors, and to try to make the best use of its performance. Stylus-ball-radius and center-alignment errors are proved, and the probing error mechanism on the 3D measuring coordinate is analyzed using numerical expressions. Macro algorithms are developed for the compensation of these errors, and actual tests and verifications are performed with a kinematic contact trigger probe and reference sphere on a CNC machine tool.

Fast Handover Scheme for MIPv6 Based on IEEE 802.16e (IEEE 802.16e 기반 MIPv6망에서의 고속 핸드오버 기법)

  • Lim, Chi-Hun;Oh, Ryong;Dong, Jeong-Sik;Lee, Hyong-Woo;Cho, Choong-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.8A
    • /
    • pp.802-812
    • /
    • 2007
  • A Fast handover protocols for Mobile IPv6 networks can support seamless service by reducing handover latency to mobile nodes. To gain advantage derived from the fast handover in IEEE 802.16e networks, we propose a new fast handover protocol using a multiple simultaneous binding mechanism and a handover protocol based on trigger event for IEEE 802.21 in order to integrate IEEE 802.16e handover protocol and FMIPv6 handover protocol using link layer trigger. Through the numerical analysis, we compare performance of the proposed protocol and FMIPv6 protocol.