• Title/Summary/Keyword: Trigger current

Search Result 191, Processing Time 0.027 seconds

Development of the Crowbar System Using a Vacuum Switch (진공 스위치를 이용한 Crowbar 시스템의 개발)

  • 이태호;허창수;이홍식
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.12
    • /
    • pp.584-590
    • /
    • 2002
  • Crowbar system is usually applied to a pulsed power system in which a capacitor bank is discharged into a load. This provides a free wheeling path for the load current and prevents the capacitor from recharging due to a reverse voltage. Usually diodes have been used as a crowbar switch, but it is not a practical system because the cost of the diodes goes up enormously with increasing the system voltage and current. This paper presents a novel protection scheme of a charging and discharging system of a 300 kJ capacitor bank using a low-cost crowbar system which consists of a crowbar switch and resistors. Triggered vacuum switch(TVS) was used for a crowbar switch, and Rogowski coil was used to determine a trigger time of TVS. When this crowbar system is applied to our pulsed power system which consists of capacitor bank($123muF$), inductor() for forming a pulse, load resistor$(100 m\Omega)$, and a closing switch, instantaneous reversal voltage of capacitor bank could be limited less than 1.8 ㎸ until capacitor bank was charred to 17 ㎸.

Sudden Death and Ventricular Arrhythmias in Heart Failure With Preserved Ejection Fraction

  • Jae Hyung Cho
    • Korean Circulation Journal
    • /
    • v.52 no.4
    • /
    • pp.251-264
    • /
    • 2022
  • Heart failure with preserved ejection fraction (HFpEF) accounts for approximately half of all heart failure (HF) cases. The prevalence of HFpEF is increasing due to an aging population with hypertension, diabetes mellitus, and obesity. HFpEF remains a challenging clinical entity due to a lack of effective treatment options. Traditional HF medications have not been shown to reduce mortality of patients with HFpEF, and an implantable cardioverter-defibrillator is not indicated due to normal ejection fraction. Sudden death is the most common mode of death in patients with HFpEF; however, the underlying mechanisms of sudden death are not fully elucidated. Although ventricular arrhythmias are responsible for the majority of sudden deaths in general, their contribution to sudden deaths in HFpEF patients is likely less significant. The mechanisms of ventricular arrhythmias in HFpEF are 1) reduced conduction velocity due to ventricular hypertrophy, 2) delayed repolarization due to potassium current down-regulation, 3) calcium leakage due to altered excitation-contraction coupling, and 4) increased ventricular fibrosis caused by systemic inflammation. Hypertension and subsequent ventricular hypertrophy reduce the conduction velocity in HFpEF hearts via heterogeneous distribution of connexin 43. Delayed repolarization caused by potassium current down-regulation in HFpEF hearts provides a window for early afterdepolarization to trigger ventricular arrhythmias. Altered excitation-contraction coupling in HFpEF can cause calcium to leak and trigger delayed afterdepolarization. Increased systemic inflammation and subsequent ventricular fibrosis provide substrates for re-entry. Further research is warranted to investigate the detailed mechanisms of ventricular arrhythmias in HFpEF.

Clinical and laboratory factors associated with the presence of dysmorphic oocytes in intracytoplasmic sperm injection cycles

  • Tae Eun Kim;Hyun Kyung Lee;Byung Chul Jee
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.50 no.4
    • /
    • pp.270-276
    • /
    • 2023
  • Objective: This study investigated the clinical and laboratory factors associated with the presence of dysmorphic oocytes in intracytoplasmic sperm injection (ICSI) cycles. Methods: The study involved 200 ICSI cycles, performed from 2020 to 2021, that yielded at least one mature oocyte. Clinical characteristics and ovarian stimulation methods were compared between 68 cycles with at least one dysmorphic oocyte (the dysmorphic group) and 132 cycles with normal-form oocytes only (the non-dysmorphic group). Dysmorphic oocytes were characterized by dark cytoplasm, cytoplasmic granularity, cytoplasmic vacuoles, refractile bodies in the cytoplasm, smooth endoplasmic reticulum in the cytoplasm, an oval shape, an abnormal zona pellucida, a large perivitelline space, debris in the perivitelline space, or an abnormal polar body. Results: The ages of the women, indications for in vitro fertilization, serum anti-Müllerian hormone levels, and rates of current ovarian endometrioma were similar between the dysmorphic and non-dysmorphic groups. In both groups, the three ovarian stimulation regimens, two types of pituitary suppression, and total gonadotropin dose were employed similarly. However, the dual-trigger method was used more frequently in the dysmorphic group (67.6% vs. 50%, p=0.024). The dysmorphic group contained significantly more immature oocytes and exhibited significantly lower oocyte maturity (50% vs. 66.7%, p=0.001) than the non-dysmorphic cycles. Within the dysmorphic group, significantly lower oocyte maturity was found in the cycles using a dual-trigger, but not in those with a human chorionic gonadotropin trigger. Conclusion: ICSI cycles with dysmorphic oocytes are closely associated with reduced oocyte maturity. This association was observed exclusively in dual-trigger cycles.

Effect of inserting resistance's magnitude on OCR trip time in a short-circuit of distribution system (배전계통 사고시 투입저항 크기가 OCR트립 시간에 미치는 영향)

  • Ahn, Jae-Min;Kim, Jae-Chul;Lim, Sung-Hun;Kim, Jin-Seok;Moon, Jong-Fil
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.154-155
    • /
    • 2007
  • Increase of fault current due to larger power demand has increased the possibility of the breakdown of the power system. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. In this paper, the fault current limiter, which consists of a ideal switch as a trigger part and the limiter as the limiting part, has been applied into the distribution system. From the analysis for the fault current limiting operation of SFCL, the inserting resistance's magnitude has been confirmed to affect OCR trip time in a short-circuit of distribution system.

  • PDF

The Study on the Characteristics and Design Method of High-Tc Superconducting Persistent Current Switch (고온초전도 영구전류스위치의 특성 및 설계에 관한 연구)

  • 박상건;강형구;배덕권;윤용수;김태중;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.216-219
    • /
    • 2003
  • Persistent Current Switch (PCS) is used in many superconducting magnet system. To apply the high-Tc superconductor in superconducting machine such as motor, generator, MAGLEV, MRI and NMR, the study on the persistent current mode should be performed. Because persistent current mode provide best stability and homogeneous characteristics to the superconducting machine. To stabilize the superconductor system, it is important to estimate the length of PCS. If the proper length of PCS is too short, it cause serious injury to system in fault state. So we calculated the optimal length of PCS in this paper.

  • PDF

Design and Characterization of a Reactor for Matrix Type SFCLs Using Electromagnetic Field Analysis (전자장 해석을 통한 매트릭스형 한류기용 리액터 설계 및 특성해석)

  • Chung, Dong-Chul;Yun, Chang-Hun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.227-230
    • /
    • 2009
  • In this paper, we performed the optimum design of reactors for matrix-type superconducting-fault current limiters (SFCLs), using electromagnetic analysis tools. We decided a optimun position within a reactor for superconducting elements of current-limiting parts and trigger parts from the calculation of magnetic flux internsity for reactor structures. Also we decided effective distance length between two reactors through the analysis of the distribution of magnetic field, according to distance lengths between them. We designed and characterized matrix-type SFCLs, based on our optimum design of a reactor. We confirmed uniform distribution of a fault current, resulted from the improvement of simultaneous quench characteristics within our matrix-type SFCL.

Characteristic of Wave Tail According to Inductance values in 10/350 Impulse Circuit with Crowbar Switch (크로바 스위치를 적용한 10/350 임펄스 회로에서 인덕턴스에 따른 wave tail 특성)

  • Cho, Sung-Chul;Lee, Tae-Hyung;Kim, Ki-Bok;Eom, Ju-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1416_1417
    • /
    • 2009
  • This paper shows the characteristic of wave tail according to inductance values in 10/$350{\mu}s$ impulse circuit with crowbar switch. The PSpice was used to simulate the 10/$350{\mu}s$ current waveform and lightning current impulse generator was used to generate real current waveform. As a capacitor of condenser bank increases, a virtual front time increases and a time to half-value decreases. To get a perfect 10/$350{\mu}s$ current waveform, we should consider the combination of circuit values of the inductance, capacitance, time difference between trigger pulses and charged voltage of capacitor bank.

  • PDF

Characteristics Analysis of a Small Scale Persistent Current Switch System by using Coated Conductor (Coated Conductor를 이용한 소용량 영구전류스위치 시스템의 특성 해석)

  • Kim, Yeong-Sik;Yoon, Yong-Soo;Yang, Seong-Eun;Park, Dong-Keun;Ahn, Min-Cheol;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 2007
  • This paper presents characteristics analysis of persistent current switch(PCS) system on a small scale by using YBCO coated conductor(CC). A high temperature superconductor(HTS) PCS system mainly consists of a PCS, a HTS magnet load and a magnet power supply(MPS). To design the optimal heater triggering switch. the three-dimensional heat conduction model was analyzed by finite element method(FEM). The electrical equivalent model considering the n-value of CC was applied to analyze current decay during persistent current mode. In the experiment and simulation, the heater was applied with a current of 0.43A and the current was ramped up to 10A and 20A with 0.2A/s. Finally, experimental results of the HTS PCS system have been compared with the theoretical results. It has been concluded that flux creep can not influence the results because the operating current was 40% of critical current and optimal sequential operation of the PCS system is indispensable to enhance its performance.

Ultra Miniature Eddy Current Sensor with 3 Axes for On-Machine-Measurement (기상측정용 3축 구조의 초소형 와전류 센서 개발 및 평가)

  • Kim, Sun-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.3
    • /
    • pp.27-32
    • /
    • 2010
  • The OMM(On-Machine-Measurement) system has many advantages compare to conventional measurement in the way the time and cost. But, the sensor suitable to OMM system is restrictive use. Touch trigger probe sensor has long time for measurement and non-contact sensor has directional demerit. Because the long mechanical parts such as gear and lead screw for pump, injector and machine tools has big and heavy, unclamp and transferring for measurement in machining process is very difficult. This paper presents a development of ultra miniature eddy current displacement sensor with 3 axes for On-Machine-Measurement system. The accuracy of the sensor is experimentally proved in the grinding machine. In experimental results, the accuracy has under ${\pm}5\;{\mu}m$.