• Title/Summary/Keyword: Tricuspid valve stenosis

Search Result 46, Processing Time 0.02 seconds

Surgical Experience of Congenital Tricuspid Stenosis - A Report of Case - (선천성 삼첨판 협착증의 수술치험 1례)

  • Kim, Jhin-gook;Ahn, Hyuk;Oh, Byung-Hee
    • Journal of Chest Surgery
    • /
    • v.21 no.4
    • /
    • pp.700-705
    • /
    • 1988
  • A case of congenital tricuspid stenosis in 24 year old male patient is presented. The lesion was successfully corrected with prosthetic valve replacement and closure of atrial and ventricular septal defects. Especially, this is the first reported case of successful large prosthetic valve replacement to a small annulus in tricuspid valve.

  • PDF

Echocardiographic Diagnosis of Mitral Valve Dysplasia Concurrent with Mitral Stenosis and Tricuspid Valve Dysplasia in a Dog (개에서 승모판 이형성증과 병발한 승모판 협착증 및 삼첨판 이형성증의 심초음파적 특징 1례)

  • Choi, Soo-Young;Lee, Jung-Woo;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.101-104
    • /
    • 2015
  • A 4-years-old, intact male Golden retriever dog was presented with abdominal distension and dyspnea. Physical examination revealed arrhythmia and cardiac murmur. Generalized cardiomegaly, pleural effusion and ascites were shown on thoracic and abdominal radiographs. Two-dimensional echocardiography revealed abnormal mitral and tricuspid valve motion, mitral and tricuspid regurgitation, left ventricular eccentric hypertrophy and left atrial dilation. Color-flow Doppler imaging revealed turbulent flow extending into the left ventricle during diastole from the mitral valve orifice, and into the left atrium during systole. Spectral Doppler recordings revealed highly increased early diastolic mitral valve inflow and prolonged pressure half-time of mitral inflow. Based on the echocardiographic examination, the diagnosis was made as the mitral valve dysplasia concurrent with mitral valve stenosis and tricuspid valve dysplasia.

Tricuspid Valve Insufficiency due to Intracardiac Migration of a Stent Inserted into Rt. Subclavian Vein to the Right Ventricle after the Treatment of Central Venous Stenosis (중심정맥 협착 환자에서 우측 쇄골하정맥에 삽입한 스텐트의 우심실 이동으로 인한 삼첨판막 폐쇄부전 치험)

  • Cho, Seong-Ho;Cho, Sung-Rae;Park, Eok-Sung;Kim, Jong-In
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.739-742
    • /
    • 2010
  • Two stents were placed across the right subclavian vein due to stenosis of the right subclavian vein in a 40-year-old patient with chronic renal failure on hemodialysis. During the follow up period, one of stents migrated into the right ventricle inducing tricuspid valve insufficiency. Percutaneous stent removal had failed and the stent was removed by open heart surgery with Tricuspid valve repair with a good result, and then we report the case.

Transposition of great arteries with pulmonary stenosis and remote muscular inlet ventricular septal defect (원거리근육입구형심실중격결손과 폐동맥협착이 동반된 대혈관전위)

  • 김웅한;이택연;김수철;전홍주;한미영;김수진;이창하;정철현;오삼세
    • Journal of Chest Surgery
    • /
    • v.33 no.3
    • /
    • pp.262-264
    • /
    • 2000
  • We report a successful biventricular repair of D-transposition of great arteries, pulmonary stenosis and remote muscular inlet ventricular septal defect, after modifie Blalock-Taussing shunt early in infant. A long left ventricle-to-aorta intraventricular rerouting tunnel was created without stenosis by transferring the medial papillary muscle of the tricuspid valve to the tunnel, obliterating the trabeculation of right ventricle in the course of tunnel and excising the secondary chordae of the tricuspid valve.

  • PDF

Intractable Hemoptysis due to Valvular Heart Disease Treated by Emergency Redo DVR: 1 case report (판막부전증에 의한 대량객혈의 응급 이중판막 재치환술: 1례 보고)

  • 이재훈;전양빈
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.423-427
    • /
    • 1997
  • Hemoptysis occurs quite frequently as a consequence of mitral stenosis, but massive, lirE threatening pulmonary hemorrhage is distinctly unusual. We report a 30 year old female who underwent cmcrgcncy rcdo double valve replacement for intractable pulmonary hemorrhage. she underwent mitral valve replacement (lonescu Shirley 27 mm) due to rheumatic valvular heart disease in 1984 and tricuspid valve annuloplasty (Carpentier's rlng 30mm) two years later She was admitted for massive hcmoptysis and dyspnea on the 26th of December, 1995. Medical treatment including transarterial embolization was given but was not satisfactory. Emergency valve replacement (Mitral valve , 51. Judc 29mm and tricuspid valve ; 51. Jude 33mm) was performed and hemoptysis was controlled dramatically 24 hours after surgery.

  • PDF

Clinical Study of Multiple Cardiac Valve Replacement : A Report of 63 Cases (중복심장판막이식의 임상적 고찰 63예 보고)

  • Suh, Kyung-Pill;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.405-413
    • /
    • 1980
  • A total of 63 patients [42 males and 21 females] underwent multiple valve replacement with artificial valves between January 1975 and August 1980 at Seoul National University Hospital. There were 38 patients with aortic and mitral valve replacement, 22 with mitral and tricuspid, and 3 with aortic, mitral and tricuspid valve replacement. The valve lesions varied from trivial to severe and most aortic and mitral valves had mixed stenosis and insufficiency, while tricuspid valves had only insufficiency. The patients were severely symptomatic in majority of the cases, and belonged to the Classes III and IV [III:45, IV:16] of the NYHA functional criteria. Hemodynamic studies were performed on all the patients. The mean pulmonary wedge pressure was remarkably increased to 19.8 mmHg in aortic and mitral valve lesions and 18.0 mmHg in mitral and tricuspid valve lesions. The mean pulmonary arterial pressure was also increased, while the cardiac index was reduced. In 1977, the average perfusion time was 245.5 minutes for aortic and mitral valve replacement and 181.6 minutes for mitral and tricuspid valve replacement. It has progressively declined to 169.2 minutes for aortic and mitral valve replacement and 123 minutes for mitral and tricuspid valve replacement in 1980. The average period of aortic occlusion also declined after the use of cardioplegic solution. Twenty deaths occurred among the 63 patients operated upon, an overall mortality rate of 30.8%. The operative mortality has declined with successive year from a level of 66.7% before 1977 to 21.1% in 1980. Fourteen patients suffered from a list of postoperative complications, which eventually resolved with adequate treatment. All the survivors were enjoying the levels of daily life activities greater than those existing before the operation.

  • PDF

4D flow MRI based flow visualization and quantification of bicuspid valvular flow using ex-vivo porcine model (4차원 자기공명영상을 활용한 돼지 심장 ex-vivo 이첨판 모델 유동 가시화 및 유동 특성 분석)

  • Minseong Kwon;Sungho Park;Hyungkyu Huh
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.1
    • /
    • pp.12-17
    • /
    • 2023
  • Aortic valve stenosis is a heart valve disease caused by the accumulation of calcium in the valve, which can divide into tricuspid aortic valve (TAV) stenosis and bicuspid aortic valve (BAV) stenosis depending on the shape of natural valve. In this study, pig heart-based TAV and BAV ex vivo models were fabricated, and the flow characteristics behind a valve were analyzed using 4D flow MRI. Flow behind normal TAV was uniformly distributed, while BAV asymmetrically opened with an eccentric strong jet. Especially, BAV ex vivo model exhibited a secondary flow in the region where the valve closed. In addition, BAV had a 26% higher peak velocity while maintaining similar stroke volume compared with normal TAV. This study would be helpful for understanding the flow characteristics for BAV AS patients.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Cardiac Surgery : A report of 1640 cases (심장질환의 외과적 치료 -1640 수술예 보고-)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.92-99
    • /
    • 1980
  • From 1958 up to the end of April 1980, during the period of 12 years 1640 cardiac surgery cases including 1069 open heart surgery and 304 valve replacement cases, were operated in this Department. There were 1070 congenital anomaly and 570 acquired disease cases. In 1070 congenital anomaly cases 673 acyanotic and 397 cyanotic anomaly patients were noted. In acquired diseases 94 pericardial and 456 valvular cases were found. Among 456 valve cases 189 mitral stenosis, 133 mitral insufficiency, 30 aortic valve lesion, 97 double valve, and 7 triple valve lesion patients were noted. Among 304 valve replacement cases 209 mitral, 34 aortic, 5 tricuspid, 34 aortic with mitral, 20 mitral with tricuspid, and 2 triple valves were replaced. Annual increase `of open heart surgery cases and decrease of operative deaths were remarkable in recent years. In recent years Shiley** oxygenator in pump-oxygenator set up and Ionescu** bovine pericardial xenograft bioprosthesis were used for valve replacement mainly.

  • PDF

Univentricular heart: a report of 2 cases (단심실증의 수술치험 2)

  • 박이태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.625-631
    • /
    • 1984
  • A modified Fontan procedure was performed on two patients with Univentricular heart. The first patient had UVH of right ventricular type with trabecular pouch and had various associated anomalies, such as common atrium, common atrioventricular valve and combined pulmonary stenosis. The second patient had UVH of left ventricular type with outlet chamber and the associated anomalies were atrial septal defect, tricuspid stenosis and combined pulmonary stenosis. Postoperative hemodynamic insufficiency, fluid retention and renal insufficiency were occurred in the first patient, but relieved with the aid of inotropics and vasodilators. We thought that the good postoperative course and surgical result were gained from the widely patent atriopulmonary anastomosis.

  • PDF