• Title/Summary/Keyword: Trendline

Search Result 7, Processing Time 0.018 seconds

Standard Curve Validation using Trendlines in Excel (Excel의 추세선을 이용한 표준곡선 검증)

  • Lee, Kyung-Hwa;Park, Hyung-Ki;Shin, Young-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.69-74
    • /
    • 2016
  • Purpose Using a regression formula of the trendline near the coefficient of determination (R2) "1" by substituting the dependent variable of the standard curve to calculate the values of the independent variable. To determine the suitability of a regression equation by comparing the difference between the independent variables of the standard curve and the predicted independent variables. Materials and Methods Perkin Elmer Gamma-Counter machine was used for Standard curve of regression methods. TSH. TG-Ag (Thyroglobulin Antigen), Insulin that used materials and method test to compare the result from the Excel trendline of the regression formula. Results Each of the value of coefficient of determination ($R^2$) and Trendline $R^2=1$, Polynomial Trendline for TSH, $R^2=1$, Polynomial Trendline for TG-Ag, $R^2=0.9994$, Polynomial Trendline for Insulin. Conclusion We confirmed that IRMA immune method is found to the nearest trends elected a standard curve using polynomial trendline. The independent variables to predict the trend by using a polynomial trendline formula containing the error was a limitation.

  • PDF

Analysis on the Interference Effects of Radio-Relay Stations into HAPS System (무선중계국이 HAPS 시스템에 미치는 간섭 영향 분석)

  • Kim, Bong-Seok;Park, Sang-Jun;Ham, Hyung-Il;Kang, Young-Heung
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.1
    • /
    • pp.10-16
    • /
    • 2002
  • High altitude platform station(HAPS) is being developed actively in some countries as well as Korea. At the same time Resolution 734 was adopted in WRC-2000 to study the sharing of HAPS into the existing fixed services in the bands above 3GHz. As one of the sharing studies, interferences between HAPS and radio-relay stations should be analyzed by dividing into two cases, the one is the interference effects of HAPS system into radio-relay stations and on the contrary, the other that of radio-relay stations into HAPS system. Since the former case had been already studied, only the latter case will be focused on this paper. Analysis result shows that the coordination distance must be needed above 100 km when the trendline of radio-relay is located vertical to HAPS service area and the transmitting power is -50 dBW/MHz.

  • PDF

Requirement Analysis and Drag Prediction for the Aerodynamic Configuration of a Bearingless Rotor Hub (무베어링 로터 허브 형상에 대한 요구도 분석 및 항력 예측)

  • Kang, Hee-Jung
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • The requirement for the aerodynamic hub drag, allocated from the system requirement of development of a bearingless rotor hub, was analyzed and embodied to be substantiated by the methodology assigned from the requirement. Drag prediction for the initial hub configuration was carried out by hand calculation using aerodynamic drag coefficients and the design change about the sectional shape of torque tube was suggested to satisfy the requirement. Finally, drag prediction was performed for the changed hub configuration by using unstructured overset mesh technique and parallel computation and the calculated result satisfied the requirement of the aerodynamic hub drag. It was found that the drag of final hub configuration was also within the range of drag inferred from the trendline of developed helicopter.

Development of Endurance Estimation Method for Multicopters Using Propeller Database (프로펠러 성능 시험 데이터베이스를 활용한 멀티콥터 체공시간 예측방법 개발)

  • Choi, Inseo;Han, Cheolhuei
    • Journal of Institute of Convergence Technology
    • /
    • v.11 no.1
    • /
    • pp.33-37
    • /
    • 2021
  • The application of multicopters using a battery is limited by the short endurance due to the low energy density. A propeller is one of crucial components that determine the performance of the multicopter. In the present study, a systematic method for predicting the endurance of multicopters is described. Propeller performance database are constructed using the data from UIUC Propeller Data Site. Using the 'trendline' function of MS Excel software, the performance of the commercial propellers are represented as a function of polynomials. The multicopter's endurance is computed iteratively using Peukert's Law and considering the voltage drop effect. We evaluated the endurance of multicopters that use commercial propellers. The endurance of the multicopter was within the range of 28 min. to 36 min. It is expected that the present method can be utilized for optimal propeller selection for the given multicopters.

A study on the sharing between NGSO/MSS service link and existing fixed-service microwave system (NGSO / MSS 서비스링크와 기존 고정서비스 마이크로웨이브 시스템간의 주파수 공유에 관한 연구)

  • 이성수;조삼모;김혁제
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.1
    • /
    • pp.115-125
    • /
    • 1998
  • This paper examined the feasibility of adding a new NGSO/MSS(Non-Geostationary orbit/Mobile satellite service) service link to a frequency band which is already allocated to fixed-service microwave(M/W) system. To achieve this goal, the NGSO/MSS handset performance under the influence of the M/W multiple stations and the influence of handsets on the M/W station were both analyzed. Sharing criterions were also obtained by means of coordination contour in the former case, and handset capacity in the latter case. As the results, it was proven that sharing was feasible only when the vertical distance between handset and trendline was above 4 km except front and back points of M/W antenna bore sight under influence of 9 hops(the distance between hops = 50 km) M/W system on the NGSO/MSS handset, and only when the capacity of handset was below $7.0\times10^{-14}$ handsets/ $m^{2}$ under influence of handsets on the M/W station.

  • PDF

Detecting Research Trends in Korean Information Science Research, 2000-2011 (국내 정보학분야 연구동향 분석, 2000-2011)

  • Seo, Eun-Gyoung;Yu, So-Young
    • Journal of the Korean Society for information Management
    • /
    • v.30 no.4
    • /
    • pp.215-239
    • /
    • 2013
  • Even though the overall scholarly community has recognized a dramatic growth and changes in the Information Science research in Korea over the last few decades, there are still only few studies that have identified the changes in terms of long-term and dynamic point of view. We have analyzed 1,007 IS-research articles from leading Korean journals in KCI (Korea Citation Index), published between 2000 and 2011. To discern the trendline of changes in research interests over time, we conducted a time-series analysis by developing grounded subject scheme from the article set and checking the growth rate of the number of published articles and title keywords. A comparative analysis was also conducted by constructing and comparing co-word maps over time to discover visible changes in research topics over this 12-year period of the IS-research in Korea. As a result, we identified some developments and transformations in major subject areas and knowledge structure of the IS-research in Korea over time. The major trend we discovered is that IS-studies over the 12-year period evolved from system-oriented research to library-application research. The changes are especially observed in knowledge management, Web-based system evaluation, and information retrieval areas. When compared to the results of other studies, the result of our study may serve as an evidence of the localization of Korean IS-studies in the first decade of the $21^{st}$ century.

Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment (진단용엑스선촬영장치의 간접 선량 계산법 개발)

  • Kim, Jung-Su;Kim, Sung-Hwan;Jeon, Min-Cheol;Ju, Won-Ha;Jeong, Min-Gyu;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.