• Title/Summary/Keyword: Treatment resistance

Search Result 3,629, Processing Time 0.033 seconds

An Electrochemical Evaluation on the Corrosion Resistance of Welding Zone due to Kinds of Repair Welding Filler Metals and Post Weld Heat Treatment (보수용접봉의 종류와 용접후 열처리가 용접금속부의 내식성에 미치는 영향에 관한 전기화학적 평가)

  • Shin, Jae-Hyun;Moon, Kyung-Man
    • Corrosion Science and Technology
    • /
    • v.9 no.6
    • /
    • pp.310-316
    • /
    • 2010
  • Recently a fuel oil of the diesel engine of the marine ship is being changed with heavy oil of low quality as the oil price is higher more and more. Therefore the wear and corrosion in all parts of the engine such as cylinder liner, piston crown, spindle and seat ring of exhaust valves are predominantly increased. In particular the degree of wear and corrosion of piston crown is more seriously compared to the other parts of the engine due to operating in severe environment such as the high temperature of exhaust gas and repeating impact. Thus the repair weldment of the piston crown is a unique method to prolong the its life in a economical point of view. In this case, filler metals having a high corrosion and wear resistance such as stellite 6, Inconel 625 and Inconel 718 are mainly being used for repair welding. However it has been often happened that piston crown on the ship,s job site is being actually inevitably welded with mild filler metals. Therefore in this study, filler metals such as E4301, E4313 and E4316 were welded at SS401 steel as the base metal, and corrosion property of their weld metals in the case of post weld heat treatment or not was investigated with some electrochemical methods such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram and polarization resistance etc. in 0.1% $H_2SO_4$ solution. Corrosion resistance of the weld metal of E4301 was better than the other weld metals in the case of no heat treatment, however, its resistance was considerably decreased with post weld heat treatment(annealing:$625^{\circ}C$, 2 hr) compared to other weld metals. The weld metals of E4313 and E4316 showed a relatively good corrosion resistance by post weld heat treatment.

Characteristics of Micro-hardness and Corrosion of Electroless Nickel-Phosphorus Plating depending on Heat Treatment

  • Jung Seung-Jun;Park Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.4
    • /
    • pp.196-199
    • /
    • 2000
  • Electroless plating is the desirable surface treatment method which is being widely used to all kinds of material such as requiring corrosion resistance, wear resistance and conductivity, especially plating of nonconductive material. Electroless nickel deposit has particular characteristics including non-magnetic property, amorphous structure, wear resistance, corrosion protection and thermal stability. In this study, electroless nickel plating was studied with an change in hardness and corrosion resistance of electroless nickel-phosphorus deposit depending on heat treatment. The highest hardness value was obtained by heat treatment at $500^{\circ}C$ Corrosion resistance of deposit, which had been heated at $300^{\circ}C$, was excellent when it was immersed in 1M $H_2SO_4$ solution for 60 hrs.

The Development of the Hydrophobic - Low Viscosity Filling Material for the Surface Treatment for Pavement Preventive Maintenance (예방적 유지보수를 위한 소수성 저점도 AP 표면처리재 개발)

  • Choi, Jun Seong;Kim, Jo Sun
    • International Journal of Highway Engineering
    • /
    • v.16 no.2
    • /
    • pp.35-41
    • /
    • 2014
  • PURPOSES : Surface treatment is a favorable method in the pavement preventive maintenance. This study (Part I) aimed to develop the low viscosity filling material for waterproof characteristics and high penetrable and weather resistance, and a series of companion study (Part II) presents the coating characteristics and performance analysis using field and lab tests. METHODS : Hydrophobic characteristics of the advanced surface treatment material are observed and measured the filling depth and the permeability for sand and asphalt pavement specimen using the water absorption test and permeability test, X-RAY CT test. Color difference for the weather resistance using ultraviolet ray accelerated weathering test is compared with asphalt pavement specimens. RESULTS : The developed material shows the decreased water absorption and increased impermeable effect because of the hydrophobic characteristics. It is found that the filling depth is about 6mm and weather resistance is better than asphalt pavement specimen. CONCLUSIONS : The advanced hydrophobic - low viscosity filling treatment material is developed in this study (Part I) to improve the waterproof characteristics and high filling capacity and weather resistance for the pavement preventive maintenance.

Effect of Self Resistance Exercise in Women with Frozen Shoulder (동결견을 가진 여성에 대한 탄력밴드 저항운동의 영향)

  • Nam, Kun-Woo;Ha, Mi-Sook
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.2
    • /
    • pp.35-42
    • /
    • 2012
  • Background : This study was conducted to know the effect of resistance exercise using thera-band in parallel with conservative therapy in patients with frozen shoulder. Methods : We analyze subjective pain scale, ROM and shoulder functional scale 24 patients diagnosed with adhesive capsulitis were included for study. Among them, 12 patients(experiment group) were managed by resistance exercise as well as conservative physical therapy, another 12 patients(control group) were only treated by conservative therapy alone. All the patients were treated three times a week for 4 weeks, and after, and after each treatment subjective pain scale, ROM, shoulder functional score(SFI) were measured. Results : The VAS were significant reduced between experimental group and control group according to pre-treatment and post-treatment. In experimental group, the ROM and SFI has increased than control group according to pre-treatment and post-treatment. Conclusion : According to the results, we concluded that both conservative therapy and self resistance exercise using thera-band technique are more effective for increasing ROM especially flexion, abduction, internal rotation and SFI than conservative therapy alone.

  • PDF

Electrical Characteristics of Carbon Nanotubes by Plasma and Microwave Surface Treatments

  • Cho, Sang-Jin;Shrestha, Shankar Prasad;Lee, Soon-Bo;Boo, Jin-Hyo
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.905-907
    • /
    • 2014
  • The plasma and microwave surface treatments of carbon nanotubes that loaded on plastic substrates were carried out with expecting a change of carbon nanotube dispersion by increasing treatment time. The microwave treatment process was undergone by commercial microwave oven (800 W). The electrical property was measured by hall measurement and resistance was increased by increasing $O_2$ flow rate of plasma, suggesting an improvement of carbon nanotube dispersion and a possibility of controlling the resistances of carbon nanotubes by plasma surface treatment. The resistance was increased in both polyethylene terephthalate and polyimide substrates by increasing $O_2$ flow rate. Resistance changes only slightly with different $O_2$ flow treatment in measure rho for all polyimide samples. Sheet resistance is lowest in polyimide substrate not due to high carbon nanotube loading but due to tendency to remain in elongated structure. $O_2$ or $N_2$ plasma treatments on both polyethylene terephthalate and polyimide substrates lead to increase in sheet resistance.

Enhancement of Wear Resistance by Low Heat Treatment and the Plasma Source Ion Implantation of Tungsten Carbide Tool (초경 엔드밀의 플라즈마 이온 주입과 저온 열처리를 통한 내마멸성 향상)

  • Kang, Seong-Ki;Wang, Duck-Hyun;Kim, Won-Il
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.2
    • /
    • pp.162-168
    • /
    • 2011
  • In this research, nitrogen plasma source ion implantation(PSII) of non-coated tungsten carbide endmill tools was conducted with low heat treatment for increasing wear resistance. After the low heat treatment of PSIIed tools to give a homogeneity of wear resistance, the surface modification of tools was analyzed by hardness test, surface roughness and cutting forces. As for the resultant cutting forces, low heat treatment in temperature of $400^{\circ}C$ and $500^{\circ}C$ is stable because of low cutting resistance. The 20-minutes heat treated tool at spindle speed 25000rpm has superiority of surface roughness, Ra of $0.420{\mu}m$ and was found to have good wear resistance. The higher hardness value was obtained by increasing temperature from $300^{\circ}C$ to $600^{\circ}C$ for PSIIed tools with low heat treatment. As the PSIIed tools under 10minutes at temperature of $600^{\circ}C$ have the highest hardness as Hv of 2349.8, It was analyzed that temperature processing give much influences on hardness.

Effect of Cryogenic Treatment on Wear Resistance of STD 11 Steel (STD 11강 마모특성에 미치는 서브제로처리의 영향)

  • Hong, Young Hwan;Song, Keun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.3
    • /
    • pp.134-140
    • /
    • 2003
  • Effects of cryogenic treatment and tempering temperature on the amount of retained austenite, hardness and wear properties has been investigated using alloy tool steel, STD 11. Cryogenic treatments were performed at the temperatures of $-100^{\circ}C$, $-150^{\circ}C$ and $-196^{\circ}C$, and tempering were performed at $200^{\circ}C$ and $530^{\circ}C$. It was shown that lower hardness value was obtained on high temperature ($530^{\circ}C$) tempering even after cryogenic treatment. And retained austenite was not entirely transformed to martensite after cryogenic treatment even at $-196^{\circ}C$, which was not consistent with the belief that $-80^{\circ}C$ was sufficient to entirely transform any austenite retained in the quenched microstructure. Austenite retained in cryogenic treated condition was completely transformed to martensite only after tempering at $530^{\circ}C$. As far as wear test conditions in this investigation, it was found that cryogenic treatments improved the sliding wear resistance, but improvement of wear resistance was not directly related with retained austenite contents. And it was found that predominent wear mechanisms of STD 11 steel were oxidation wear and adhesive wear In sliding wear conditions.

The effect of Ar plasma treatment on Al-doped ZnO (Ar 플라즈마 처리에 따른 Al-doped ZnO 박막특성변화)

  • Jin, Sun-Moon;Ahn, Chul-Woo;Cho, Nam-In;Nam, Hyoung-Gin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.43-46
    • /
    • 2011
  • In this study, we investigated the effects of the post Ar plasma treatment at different RF powers for various durations on electrical, structural, and optical properties of relatively thin Al-doped zinc oxide films. The sheet resistance was observed to decrease rapidly for the first 5min, beyond which the resistance apparently saturated. As the RF power increased, the grain size and the interplanar distance of (002) planes also increased. The observed decrease in sheet resistance was stated to be a consequence of Al and/or Zn interstitials as well as grain growth. It was also found that Ar plasma treatment increased the transmittance of Al-doped zinc oxide films in most of the visible light range below the blue light.

Pseudo-Resistant Schizophrenia: Non-Adherence to Treatment (치료 위저항성 조현병: 치료 비순응을 중심으로)

  • Kim, Hyerim;Lee, Seung Jae
    • Korean Journal of Schizophrenia Research
    • /
    • v.23 no.2
    • /
    • pp.51-57
    • /
    • 2020
  • Treatment-resistant schizophrenia (TRS) has been defined as the persistence of positive symptoms despite two or more trials of antipsychotic medication of adequate dose and duration. TRS is a serious clinical problem and occurs in approximately 30% of patients with schizophrenia. It is important that patients who do not adequately respond to antipsychotics be reevaluated to exclude or address causes other than non-responsiveness to medication, that is, the possibility of pseudo-resistance. In particular, non-adherence to oral antipsychotic treatment should be monitored to rule out pseudo-resistant cases of TRS. Moreover, patients with TRS who take their medication as required may have subtherapeutic antipsychotic plasma levels, secondary to pharmacokinetic factors. In this paper, we review the concept and exclusion of pseudo-resistance, especially owing to non-adherence or pharmacokinetic factors, and present methods to enhance drug adherence.

Effects of Heat Treatment on Corrosion Resistance Properties of Gas Nitrided Stainless Steels (스테인레스강의 가스질화 후 내식특성에 미치는 열처리조건의 영향)

  • Kim, H.G.;Kim, Y.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.5
    • /
    • pp.298-306
    • /
    • 2009
  • Gas nitriding and post oxidation were performed on stainless steels and SACM 645 steel. With increasing gas nitriding time, the increasing rate of nitrided layer was most rapid on SACM 645 steel and the nitriding depth of nitrided layer was most narrow on STS 304 steel among three steels. Corrosion resistance was increased with post oxidation on stainless steels and with increasing time the effect of corrosion resistance was decreased to compare with relatively short gas nitriding time. An improvement effect of corrosion resistance was consisted of predominantly on austenitic stainless steel by post oxidation after gas nitriding among three steels and it was relatively less influenced on martensitic stainless steel.