• Title/Summary/Keyword: Treatment field

Search Result 4,520, Processing Time 0.032 seconds

The Field Modulation Effect of a Fluoride Plasma Treatment on the Blocking Characteristics of AlGaN/GaN High Electron Mobility Transistors

  • Kim, Young-Shil;Seok, O-Gyun;Han, Min-Koo;Ha, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.12 no.4
    • /
    • pp.148-151
    • /
    • 2011
  • We designed and fabricated aluminium gallium nitride (AlGaN)/GaN high electron mobility transistors (HEMTs) with stable reverse blocking characteristics established by employing a selective fluoride plasma treatment on the drainside gate edge region where the electric field is concentrated. Implanted fluoride ions caused a depolarization in the AlGaN layer and introduced an extra depletion region. The overall contour of the depletion region was expanded along the drift region. The expanded depletion region distributed the field more uniformly and reduced the field intensity peak. Through this field modulation, the leakage current was reduced to 9.3 nA and the breakdown voltage ($V_{BR}$) improved from 900 V to 1,400 V.

필터시스템을 이용한 비소처리흡착제의 성능비교분석

  • Bang Seon-Taek;Kim Ju-Yong;Kim Gyeong-Ung
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.13-16
    • /
    • 2005
  • Laboratory and field experiments were conducted to study the effectiveness of five adsorbents for the removal of arsenic. The adsorbents included activated alumina (AA), iron coated AA (ICAA), and granular ferric hydroxide (GFH), granular ferric oxide (GFO), and granular titanium dioxide (GTD). Laboratory experiments were conducted to investigate arsenic removal using challenge water prepared in accordance with NSF International Standards 53 (ANSl/NSF 53-2001). Field experiments were conducted using arsenic-contaminated groundwater In laboratory experiment, the treatment capacity decreased in the following order GTD > GFO > GFH. In contrast, the treatment capacity decreased in the following order GFO > GTD > GFH > ICAA > Ah in field experiments.

  • PDF

Study on dose comparison using X-Jaw split in VMAT treatment planning for left breast cancer including supraclavicular lymph nodes. (쇄골 상부 림프절을 포함하는 왼쪽 유방암의 VMAT 치료계획시 X-Jaw split을 이용한 선량비교에 관한 연구)

  • Kim, Hak Jun;Lee, Yang Hoon;Min, Jae Soon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.137-144
    • /
    • 2021
  • Purpose : The usability of X-Jaw split VMAT was evaluated by comparative analysis of the dose distribution between the treatment plan divided by X-Jaw and Full field VMAT treatment plan in left breast cancer treatment including supraclavicular lymph nodes. Materials and Methods : 10 patients with left breast cancer, including supraclavicular lymph nodes, were simulated using vacuum cushion, and 2 Full field Arc VMAT and 4 X-Jaw split Arc VMAT were planned The treatment plan was designed to include more than 95% of the Planning Target Volume (PTV) and to be minimally irradiated in the surrounding Organ at risk (OAR). Dose analysis of PTV and OAR was performed through dose volume histogram (DVH). Results : The Full field VMAT treatment plan and the X-Jaw split VMAT treatment plan of 10 patients were expressed as average values and compared. The difference between the two treatment plans was not large, with a Conformity index (CI) of 1.05±0.04, 1.04±0.03, and a Homogeneity index (HI) of 1.07±0.008, 1.07±0.009. For OAR, V5 in the left lung is 56.1±6.50%, 50.4±6.30%, and V20 is 20.0±4.15%, 13.52±3.61%. Compared to Full field VMAT, V5 decreased by 10.0% V20 by 32.6% in X-Jaw split VMAT. The V30 of the heart is 3.68±1.85%, 2.23±1.52%, and the Mean dose is 8.93±1.65 Gy, 7.67±1.52 Gy. In the X-Jaw split VMAT, V30 decreased by 39.3% and the Mean dose decreased by 14.1%. The left lung and heart, which are normal tissues, were found to have a statistical significance of that p-value is less than 0.05. Conclusion : In the case of left breast cancer treatment, which includes Supraclavicular lymph nodes with a large PTV volume and a length of X Jaw of 15 cm or more, the X-Jaw split VMAT shows improved dose distribution, which can reduce radiation dose of OAR such as lungs and heart, while maintaining similar PTV coverage with HI and CI equivalent to Full field VMAT. It is thought to be effective in reducing radiation complications.

Improvement of field emission character by surface treatment of carbon thin film (탄소계 박막의 표면 처리에 의한 전계전자방출 특성의 개선)

  • ;K.-Y. Lee;S.-I. Honda;M. Katayama;;K. Oura
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.147-150
    • /
    • 2002
  • The electron field emission properties of amorphous carbon (a-C) films deposited using a RF magnetron sputtering system have been improved by introducing a simple method of argon plasma treatment at room temperature. Surface morphologies and structural properties of the a-C films were investigated by scanning electron microscopy and Raman spectroscope, respectively. Structural properties and surface morphologies of the a-C films were changed by argon plasma treatment. The emission properties improved with the plasma treatment.

  • PDF

Application of Pulsed Electric Fields with Square Wave Pulse to Milk Inoculated with E. coli, P. fluorescens, and B. stearothermophilus

  • Shin, Jung-Kue;Jung, Kwan-Jae;Pyun, Yu-Ryang;Chun, Myong-Soo
    • Food Science and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.1082-1084
    • /
    • 2007
  • Ultra-high temperature (UHT) processed full fat milk inoculated with Escherichia coli, Pseudomonas fluorescens, and Bacillus stearothermophilus was exposed to 30-60 kV/cm square wave pulsed electric field (PEF) with $1\;{\mu}sec$ pulse width, and $26-210\;{\mu}sec$ treatment time in a continuous PEF treatment system. Eight log reduction was obtained for E. coli and P. fluorescens and 3 logs reduced for B. stearothermophilus under PEF treatment conditions of $210\;{\mu}sec$ treatment time, 60 kV/cm pulse intensity at $50^{\circ}$. There was no significant change in pH and titration acidity of milk after PEF treatment. The electrical energy required to achieve 8 log reduction for E. coli and P. fluorescens was estimated to be about 0.74 kJ/L.

Field Test for a Biological Nitrogen Treatment System with Low Temperature Solar Thermal Energy (저온 태양열을 이용한 생물학적 오수 처리 장치 실증 실험)

  • Chung, Mo;Lee, Dong-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.34-41
    • /
    • 2008
  • A low-temperature solar thermal system assisting a biological nitrogen treatment reservoir was designed and field-tested. A large tank whose temperature was maintained at about $25-30^{\circ}C$ to enhance the performance of a biological nitrogen treatment process was heated by an array of flat plate solar collectors. Test results revealed that the overall collector efficiency was above 50% for the most cases tested. This high efficiency was possible owing to the relatively low collector temperature that can be traced back to the reservoir temperature. A substantial enhancement in nitrogen treatment was observed as a result of maintaining the reservoir temperature higher.

The Role of Computer Simulation in Assessment and Treatment (근골격계 환자의 평가와 치료에 있어서 컴퓨터 시뮬레이션의 적용)

  • Shin, Sang-Hoon;Nam, Tong-Hyun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.2
    • /
    • pp.140-148
    • /
    • 2009
  • The primary market of acupuncture treatment is concentrated on disorders of the musculoskeletal system. This study researches the clinical use of the musculoskeletal system evaluation with a computer simulation. Two fields are examined - patient evaluation and patient treatment. In the field of evaluation, the simulation is used to evaluates the prognosis of medical treatment. In the field of treatment, the simulation is used to decide the most suitable way to perform surgery using the quantitative evaluation about various cases of surgical results.

  • PDF

Evaluation of the Breast plan using the TLD and Mosfet for the skin dose (열형광선량계(TLD)와 MOSFET을 이용한 유방암 방사선치료계획에 대한 피부선량 평가)

  • Kim, seon myeong;Kim, young bum;Bak, sang yun;Lee, sang rok;Jeong, se young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.107-113
    • /
    • 2015
  • Purpose : The measurement of skin dose is very important that treatment of breast cancer. On account of the cold or hot dose as compared with prescription dose, it is necessary to analyse the skin dose occurring during the various plan of the breast cancer treatment. At our hospital, we want to apply various analyses using a diversity of dosimeters to the breast cancer treatment. Subjectss and Methods : In the study, the anthropomorphic phantom is used to find out the dose difference of the skin(draining site), scar and others occurring from the tangential treatment plan of breast cancer. We took computed tomography scan of the anthropomorphic phantom and made plans for the treatment planing using open and wedge, Field-in-Field, Dose fluence. Using these, we made a comparative analysis of the dose date points by using the Eclipse. For the dose comparison, we place the anthropomorphic phantom in the treatment room and compared the measurement results by using the TLD and MOSFET on the dose data points. Results : On the central point of treatment planing basis, the upward and downward skin dose measured by the MOSFET was the highest when the fluence was used. The skin dose of inner and outer was distinguished from the figure(5.7% ~ 10.3%) when the measurements were fulfilled by using TLD and MOSFET. The other side of breast dose was the lowest in the open beam, on the other hand, is highest in the Dose fluence plan. In the different kinds of treatment, the dose deviation of inner and outer was the highest, and so this was the same with the TLD and MOSFET measurement case. The outer deviation was highest in the TLD, and the Inner'was highest in the MOSFET. Conclusion : Skin dose in relation to the treatment plan was the highest in the planing using the fluence technique in general and it was supposed that the high dose had been caused by the movement of the MLC. There's some differences among the all the treatment planning, but the sites such as IM node occurring the lack of dose, scar, drain site are needed pay close attention. Using the treatment planning of dose fluence is good to compensate the lack of dose, but It increases the dose of the selective range rather than the overall dose. Therefore, choosing the radiotherapy technique is desirable in the lights of the age and performance of the patient.

  • PDF

Application of Pulsed Electric Field Treatment for Scaling Prevention (스케일형성 방지를 위한 펄스 전기장 처리의 적용)

  • Choi, Seung-Pil;Kim, Jong-Oh
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.10
    • /
    • pp.51-56
    • /
    • 2011
  • This study was conducted to investigate the applicability of pulsed electric field (PEF) treatment for the prevention of scaling formation and membrane fouling reduction. To validate the effect of PEF and to identify the mechanism, some experiments with and without PEF treatment were carried out. PEF treatment affected the precipitation of $CaCO_3$ by which $CaCO_3$ particles were actively grown and sedimented. It was confirmed that the calcium ions were decreased as 78% and particle size was grown by PEF treatment. It was also verified that the crystalline structure of $CaCO_3$ was transformed by PEF treatment from Aragonite, which is formed at a high temperature and hard to be removed, to Calcite being stable at room temperature. In PEF treatment, permeate volume and permeation flux were greater than that of without PEF, case while Langelier Index(LI) decreased. From the experiment results, PEF treatment is believed to be an effective method to prevent scaling formation and to mitigate $CaCO_3$ fouling as the pretreatment of membrane filtration.

Study of Acute Myelocytic Leukemia Patient Treatment That Used Total Skin Electron Beam (Total Skin Electron Beam을 이용한 급성 골수성 백혈병 환자 치료에 대한 연구)

  • Lee, Sang-Ryul;Kang, Min-Kyu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.152-158
    • /
    • 2009
  • Total Skin Electron Beam Therapy (TSEBT) of linear accelerator has become use so as to be useful, 2~9 MeV of energy territories came to be used with mycosis fungoides and cutaneous lymphomas in the superficial lesion treatment which covers the major portion of the body. I treat a patient to Stanford technique in this study, and it is $60^{\circ}$ around the patients whom Stanford technique irradiated electronic beam to a linear accelerator in horizontal directions and there is a way a standard of TSEBT treat it to six located field (anterior, posterior, and four obliques) becoming. An each field does horizontally it and consist to beam of the two component which fitted the center to a suitable angle. a patient treats it to three dual field a day in order to make short treatment time. when a first day, we treat one dual field at anterior position and two dual field at posterior position. when the second day, treat one dual field at posterior position and two dual field at anterior position. Therefore, six dual field is finished in perfect periodic two days. we made cylindrical acrylic phantom, and I inserted a dosimeter film between phantom. in order to measure a dose distribution calculation before treat a patient, and a patient checked it in six field directions that got from a treatment. It is after that thermoluminescent dosimetry (TLD) as it uses Rando phantom and then measurement dose distribution in six field directions after attaching at chest, the right and left flank, a back after irradiation.

  • PDF