• 제목/요약/키워드: Treatment environment

검색결과 5,732건 처리시간 0.031초

Comparison of Brood Productions in the Cold-Treated Pairing vs. Not Cold-Treated Pairing in a Stenochronous Spider

  • Kim, Kil-Won
    • Journal of Ecology and Environment
    • /
    • 제32권3호
    • /
    • pp.145-148
    • /
    • 2009
  • To understand whether experience of cold season in reproductive behaviors in the adults of Amaurobius ferox, the paired adults of a female and a male were exposed under 'cold-treated environment' and 'not cold-treated environment', respectively. I investigated effects of the cold treatment on the brood production of A. ferox. In not cold treatment in which male-female pairs were formed in October at a temperature of $20^{\circ}C$ (${\pm}2^{\circ}C$) and continuously kept under not cold-treated environment, only 3 of 50 pairs successfully reproduced (reproduction was defined as the emergence of spiderlings). In cold treatment where individuals were kept in cold conditions for 3 months prior to pair formation, 57 out of 60 couples succeeded in reproducing. Females which did not experience the low temperature displayed strong aggressiveness toward males. This behavioral inhibition might the primary barrier to copulation of A. ferox that decrease following a period of low temperature. The reproductive inhibition might help the females to allocate the maximum amount of energy in a given environment to reaching the adult stage and to delay reproduction in unfavorable wintering conditions.

회귀분석을 이용한 반월 공단배수의 생태독성 원인물질 조사 (Investigation of Eco-toxicological Substances in Banwol Industrial Drainages using the Regression Analysis)

  • 김요용;우정식;황선민;김문정
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.467-472
    • /
    • 2012
  • In this study, water quality and acute toxicity using Daphnia magna were analyzed to investigate the eco-toxicological substances identified as statistical analysis and propose a management plan for the effluent of Banwol industrial complex, Ansan, Gyeonggi-do. Cu, Zn, F, Mn concentrations in the effluent far exceeded the US standards to protect the aquatic ecosystem and eco-toxicity values were 5 ~ 22 TU. However, concentrations of heavy metals significantly decreased after Ansan public wastewater treatment plant operating a biological treatment and toxicity values were 0 TU. Zn, Cr, F and Cu in the effluent showed very strong and strong positive correlations with eco-toxicity values, respectively. Regression analysis resulted in an equation between toxicity and Zn, TU = $4.884{\times}Zn$ (mg/L) -0.391 showing Zn concentration should be managed less than 0.285 mg/L to keep the eco-toxicity (TU) less than 1.

Pilot scale membrane separation of plating wastewater by nanofiltration and reverse osmosis

  • Jung, Jaehyun;Shin, Bora;Lee, Jae Woo;Park, Ki Young;Won, Seyeon;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • 제10권3호
    • /
    • pp.239-244
    • /
    • 2019
  • Plating wastewater containing various heavy metals can be produced by several industries. Specifically, we focused on the removal of copper (Cu2+) and nickel (Ni+) ions from the plating wastewater because all these ions are strictly regulated when discharged into watershed in Korea. The application of both nanofiltration (NF) and reverse osmosis (RO) technologies for the treatment of wastewater containing copper and nickel ions to reduce fresh water consumption and environmental degradation was investigated. In this work, the removal of copper (Cu2+) and nickel (Ni+) ions from synthetic water was studied on pilot scale remove by before using two commercial nanofiltration (NF) and reverse osmosis(RO) spiral-wound membrane modules (NE2521-90 and RE2521-FEN by Toray Chemical). The influence of main operating parameters such as feed concentration on the heavy metals rejection and permeate flux of both membranes, was investigated. Synthetic plating wastewater samples containing copper ($Cu^{2+}$) and nickel ($Ni^{2+}$) ions at various concentrations(1, 20, 100, 400 mg/L) were prepared and subjected to treatment by NF and RO in the pilot plant. The results showed that NF, RO process, with 98% and 99% removal for copper and nickel, respectively, could achieve high removal efficiency of the heavy metals.

Fouling behaviours of two stages microalgae/membrane filtration system applied to palm oil mill effluent treatment

  • Teow, Yeit Haan;Wong, Zhong Huo;Takriff, Mohd Sobri;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.373-383
    • /
    • 2018
  • Fouling by solids and microorganisms is the major obstacle limiting the efficient use of membrane wastewater treatment. In our previous study, two stages microalgae/membrane filtration system was proposed to treat anaerobic digested palm oil mill effluent (AnPOME). This two stages microalgae/membrane filtration system had showed great potential for the treatment of AnPOME with high removal of COD, $NH_3-N$, $PO_4{^{3-}}$, TSS, turbidity, and colour. However, fouling behavior of the membrane in this two stages microalgae/membrane filtration system was still unknown. In this study, empirical models that describe permeate flux decline for dead-end filtration (pore blocking - complete, intermediate, and standard; and cake layer formation) presented by Hermia were used to fit the experimental results in identifying the fouling mechanism under different experimental conditions. Both centrifuged and non-centrifuged samples were taken from the medium with 3 days RT intervals, from day 0 to day 12 to study their influence on fouling mechanisms described by Hermia for ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) filtration mode. Besides, a more detailed study on the use of resistance-in-series model for deadend filtration was done to investigate the fouling mechanisms involved in membrane filtration of AnPOME collected after microalgae treatment. The results showed that fouling of UF and NF membrane was mainly caused by cake layer formation and it was also supported by the analysis for resistance-in-series model. Whereas, fouling of RO membrane was dominated by concentration polarization.

A study on membrane technology for surface water treatment: Synthesis, characterization and performance test

  • Haan, Teow Yeit;Shah, Mubassir;Chun, Ho Kah;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.69-77
    • /
    • 2018
  • The use of membrane as an innovative technology for water treatment process has now widely been accepted and adopted to replace the conventional water treatment process in increasing fresh water production for various domestic and industrial purposes. In this study, ultrafiltration (UF) membranes with different formulation were fabricated via phase inversion method. The membranes were fabricated by varying the polymer concentration (16 wt%, 18 wt%, 20 wt%, and 21 wt%). A series of tests, such as field emission scanning electron microscope (FESEM), pore size and porosity, contact angle, and zeta potential were performed to characterize the membranes. The membrane performance in terms of permeation flux and rejection were evaluated using a laboratory bench-scale test unit with mine water, lake water and tube well as model feed solution. Long hour filtration study of the membranes provides the information on its fouling property. Few pore blocking mechanism models were proposed to examine the behaviour of flux reduction and to estimate the fouling parameters based on different degree of fouling. 21 wt% PVDF membrane with smaller membrane pore size showed an excellent performance for surface water treatment in which the treated water complied with NWQS class II standard.

파일럿 플랜트 규모에서 일체형 침전부상공정 (SeDAF)의 설계인자 및 운전특성에 대한 실증적 평가 (Empirical evaluation for design parameters and operating characteristics of the integrated sedimentation and dissolved air flotation (SeDAF) process at the pilot-scale plant)

  • 장여주;정진홍;임현만;김원재
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.1-14
    • /
    • 2021
  • Eutrophication and algal blooms can lead to increase of taste and odor compounds and health problems by cyanobacterial toxins. To cope with these eco-social issues, Ministry of Environment in Korea has been reinforcing the effluent standards of wastewater treatment facilities. As a result, various advanced phosphorus removal processes have been adopted in each wastewater treatment plant nation-widely. However, a lot of existing advanced wastewater treatment processes have been facing the problems of expensive cost in operation and excessive sludge production caused by high dosage of coagulant. In this study, the sedimentation and dissolved air flotation (SeDAF) process integrated with sedimentation and flotation has been developed for enhanced phosphorus removal in wastewater treatment facilities. Design and operating parameters of the SeDAF process with the capacity of 100 ㎥/d were determined, and a demonstration plant has been installed and operated at I wastewater treatment facility (located in Gyeonggi-do) for the verification of field applicability. Several empirical evaluations for the SeDAF process were performed at demonstration-plant scale, and the results showed clearly that T-P and turbidity values of treated water were to satisfy the highest effluent standards below 0.2 mg/L and 2.0 NTU stably for all of operation cases.

전기화학적 기법을 통한 시멘트페이스트의 수중노출에 따른 알칼리이온 침출저감 효과: Part 2- 미세구조 분석 (The Effect of Electrochemical Treatment in Lowering Alkali Leaching from Cement Paste to an Aquatic Environment: Part 2- Microscopic Observation)

  • 윤범희;안기용
    • 한국건설순환자원학회논문집
    • /
    • 제11권2호
    • /
    • pp.145-152
    • /
    • 2023
  • 본 연구에서는 알칼리 이온의 침출을 완화하기 위해 전기화학적 처리로 100일 동안 수중 환경에 침지된 시멘트 페이스트의 표면을 현미경으로 관찰하였다. 계면 영역에서의 미수화물 입자와 공극률을 정량적으로 평가하기 위하여 주사 전자 현미경을 통해 후방 산란 전자(BSE) 이미지를 얻었다. 그 결과, 전기화학적 처리에 의해 표면부의 공극률이 크게 감소한 반면, 전하 상태에서 제한된 수화반응에 의해 미수화 입자는 다소 증가한 것으로 나타났다. 전기화학적 처리에서, C-S-H 겔에 존재하는 Ca2+ 이온은 공극수 내의 OH- 이온과 Ca(OH)2 형태로 침전되어 C-S-H 겔을 낮추면서 동시에 Ca(OH)2를 증대시킬 수 있다. 실질적으로 알칼리 침출에 대한 위험성은 전기화학적인 처리 하에서 제한된 이온화 매트릭스에 의해 감소될 수 있다.

항균성 천연물질의 도포방법에 따른 에어필터 여재의 항균 특성 비교 (Comparison of Antibacterial Ability of Air Filter Media Treated with a Natural Antibacterial Agent by Three Treatment Methods)

  • 박선영;정재희;황기병;배귀남;김용표;노주원
    • 한국대기환경학회지
    • /
    • 제29권2호
    • /
    • pp.125-134
    • /
    • 2013
  • Various antimicrobial technologies have been developed to inactivate bioaerosols in indoor environments. In this study, air filter media were treated with a natural antibacterial agent of Sophora flavescens in order to inactivate the bacteria collected on the air filter. Three treatment methods were applied to manufacture the test antibacterial air filter media: electrospray, nebulization and dip-coating methods. In case of electrospray and nebulization processes, the size distribution of aerosolized natural antibacterial agent was measured using a scanning mobility particle sizer. Staphylococcus epidermidis bacteria were aerosolized to test inactivation of the filter media treated with a natural antibacterial agent. The pressure drop and the antibacterial efficiency of the filter media increased with increasing the mass loading of natural antibacterial agent in each treatment method. The antibacterial efficiency per loaded antibacterial agent mass by the electrospray method was the highest and the filter treated by the dip-coating method was the lowest among three treatment methods.

다단토양층을 이용한 하수처리에 관한 연구 (Study of Sewage Treatment using Multi-soil-layering System)

  • 손대희;정윤철;신정훈;정진영;안대희
    • 한국물환경학회지
    • /
    • 제20권3호
    • /
    • pp.215-222
    • /
    • 2004
  • The sewages produced from small villages, rural community, drinking water reservation area and park which doesn't have sewage piping system can be caused a serious water pollution at the restricted areas. The objective of this research was to suggest an economical and effective sewage treatment method by investigating the removal of the organics, nitrogen, and phosphorus in the multi-soil-layering reactor. Soil, natural zeolite, and iron slag were used as a supporting media of multi-soil-layering in this research. The purpose of natural zeolite addition was to maintain the consistent ammonium exchange capacity by providing a sequential environment, and that of iron slag addition was to remove phosphorus by adsorption. Continuous experiment of lab-scale single-soil-layering (S-1), multi-soil-layering (S-2), and mixed-soil-layering (S-3) methods were studied to compare and optimize three different types of the reactors. The organic removal efficiencies showed more than 90% in all three reactors. While S-1 and S-3 reactors showed about T-N removal of 31%, 45%, respectively, the average T-N removal efficiency of the S-2 reactor represented an 87%. In conclusion, that results suggest that the multi-soil-layering reactor could be effectively utilized as a plant for treatment of small village sewage.

벼 재배에서 양돈분뇨 액비 시용시 양분이동 (Nutrient Transfer in the Application of the Swine Slurry Liquid Fertilizer in Rice Paddy)

  • 권순익;김권래;김민경;정구복;홍승길;신중두;박우균;성기석;이덕배
    • 유기물자원화
    • /
    • 제18권4호
    • /
    • pp.77-85
    • /
    • 2010
  • 양돈분뇨의 처리는 환경문제 해결과 자원으로서의 이용 등 중요한 의미가 있다. 본 연구에서는 양돈분뇨의 처리 및 자원화 방법으로 개발된 SCB 액비를 토양에 시용했을 때 양분이 작물에 흡수 이용되는 양과 토양중에 잔류하는 양을 조사하여 SCB 시용량 및 시용방법 결정을 위한 기초자료를 제공하고자 하였다. 무비, 화학비료, 저장액비, SCB 액비를 완전임의배치 5반복으로 처리하여 시험을 수행하였다. 벼의 생육은 화학비료구에서 가장 좋았고, 다음으로 저장액비, SCB 액비, 무비구 순이었다. 볏짚 수량 역시 화학비료 처리구에서 가장 많았으며, 다음으로 저장액비, SCB 액비, 무비구 순이었다. 생육상황은 수량까지 이어져 무비구는 처리구보다 감수 경향을 보였으며, 다른 처리구 간에는 대동소이하였다. 식물체의 무기성분 흡수량에서도 화학비료를 비롯한 처리구의 질소, 인산 등 각종 무기성분 흡수량이 무비구에 비하여 많았으나, 이를 제외한 처리 간에는 큰 차이가 없었다.