• 제목/요약/키워드: Treatment Plan

검색결과 1,558건 처리시간 0.025초

유방암 접선조사에서 PBC 알고리즘과 AAA에 따른 Field-in-Field Intensity Modulated Radiation Therapy와 Conventional Radiation Therapy 전산화 치료계획에 대한 고찰 (Study on Computerized Treatment Plan of Field-in-Field Intensity Modulated Radiation Therapy and Conventional Radiation Therapy according to PBC Algorithm and AAA on Breast Cancer Tangential Beam)

  • 염미숙;배성수;김대섭;백금문
    • 대한방사선치료학회지
    • /
    • 제24권1호
    • /
    • pp.11-14
    • /
    • 2012
  • 목 적: Anisotropic Analytical Algorithm (AAA)는 Pencil Beam Convolution (PBC) 알고리즘에 비하여 2차선과 조직 불 균질에 대한 영향에 보다 더 정확한 선량계산을 제공한다. 본 연구는 유방암 접선조사 치료계획에서 PBC 알고리즘과 AAA의 선량계산 알고리즘에 따른 선량분포의 차이를 분석하고자 한다. 대상 및 방법: 선형가속기(CL-6EX, VARIAN, USA)의 6 MV 에너지를 이용한 유방암 환자 10명을 대상으로 Eclipse treatment planning system (Version 8.9, VARIAN, USA)을 사용하여 전산화 치료계획을 수립하였다. Conventional Radiation Therapy plan(Conventional plan)과 Field-in-Field Intensity Modulated Radiation Therapy plan (FiF plan)을 PBC 알고리즘을 이용하여 치료계획을 수립한 후 Monitor Unit (MU)를 고정시키고 AAA로 변경하여 선량계산하고, Dose Volume Histogram (DVH)을 이용하여 치료계획을 비교 분석하였다. 결 과: 첫 번째, Conventional plan의 PBC 알고리즘과 AAA에 따른 차이를 평가한 결과 치료용적에 대한 평균 Conformity Index (CI) 값의 차이는 PBC 알고리즘에서 0.295 높게 평가 되었다. 동측 폐에 대한 선량을 평가한 결과 $V_{47Gy}$$V_{45Gy}$는 PBC알고리즘에서 각각 5.83%, 4.04% 높게 평가되었고, Mean dose, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$는 AAA에서 각각 0.6%, 0.29%, 6.35%, 10.23%높게 평가되었다. 두 번째, FiF plan의 경우 치료용적에 대한 평균 CI 값의 차이는 PBC 알고리즘에서 0.165 높게 평가 되었고, 동측 폐에 대한 선량은 $V_{47Gy}$, $V_{45Gy}$, Mean dose는 PBC 알고리즘에서 각각 6.17%, 3.80%, 0.15% 높게 평가되었고, $V_{20Gy}$, $V_{5Gy}$, $V_{3Gy}$는 AAA에서 각각 0.14%, 4.07%, 4.35% 높게 평가되었다. 결 론: 유방암 접선조사에서 AAA로 계산했을 때, PBC 알고리즘에 비해 치료용적에 대한 Conformity가 Conventional plan, FiF plan 각각 0.295, 0.165 낮게 평가 되며, 동측 폐의 고 선량 영역의 선량은 적게 나타나며, 저 선량 영역의 선량은 많게 나타므로 폐에 대한 선량을 평가하는 데 선량계산 알고리즘에 따른 특징을 고려해야 할 것으로 사료된다.

  • PDF

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.

두경부 토모테라피 치료 시 CT scan range에 따른 치료계획의 정확성 평가 (Accuracy evaluation of treatment plan according to CT scan range in Head and Neck Tomotherapy)

  • 권동열;김진만;채문기;박태양;서성국;김종식
    • 대한방사선치료학회지
    • /
    • 제31권2호
    • /
    • pp.13-24
    • /
    • 2019
  • 목 적: 두경부 토모테라피 치료 시 다양한 이유로 CT scan range가 부족한 상황이 발생한다. CT scan range는 정확한 선량 계산에 영향을 주기 때문에 Re-CT Simulation이 좋지만 환자의 피폭선량 증가와 불편함, 치료일정 변경 등 문제점을 갖는다. 이에 본 저자는 기존 CT scan range에서 Plan setup parameter 변화를 통해 Re-CT Simulation 없이 정확한 치료계획에 필요한 최소한의 CT scan range를 평가해보고자 한다. 대상 및 방법: CT simulator(Discovery CT590 RT, GE, USA)와 In House Head & Neck Phantom을 이용하였고, Target의 끝단에서 0.25~3.0cm까지 0.25cm씩 증가시켜 CT scan range 별 이미지를 획득하였다. Target과 정상 장기를 Head & Neck Phantom에 등록하고 ACCURAY Precision® 이용하여 치료계획을 설계하였다. 처방 선량은 Daily 2.2Gy, 27 Fxs, Total Dose 59.4Gy, Target은 처방 선량의 95~107%, 정상 장기는 SMC Protocol에 맞춰 치료계획을 설계하였다. 동일한 치료계획 조건에서 Field Width(FW)와 Jaw 모드를 고려한 5가지 방법(Fixed-1cm, Fixed-2.5cm, Fixed-5cm, Dynamic-2.5cm Dynamic-5cm)과 2가지 Pitch(0.43, 0.287)의 Plan Setup parameter로 치료계획을 설계하였다. 각 치료계획에 대한 선량 전달의 정확성은 EBT3 film과 RIT(Complete Version 6.7, RIT, USA)를 이용하여 분석하였다. 결 과: Target의 처방 선량과 정상 장기의 견딤선량(Tolerance dose)을 만족한 치료계획(SMC Protocol)은 Fixed-1cm은 0.25cm 이상, Fixed-2.5cm는 0.75cm 이상, Dynamic-2.5cm는 1cm 이상, Fixed-5cm과 Dynamic-5cm인 경우는 1.75cm 이상의 Scan range가 있어야 정확한 치료계획을 할 수 있었다. 선량 전달의 정확성은 RIT로 분석한 결과 SMC Protocol을 만족한 치료계획에서 3% 미만의 오차였다. 결 론: 두경부 토모테라피 치료 시 CT scan range가 부족한 경우 Plan Setup Parameter 중 Field Width(FW)를 조절하여 정확한 치료계획을 설계할 수 있었다. 이에 본 저자가 추천한 Plan Setup Parameter를 CT scan range에 따라 적용하고 Re-CT 여부를 판단한다면 업무의 효율성 및 환자의 피폭선량을 감소시킬 수 있을 것으로 사료된다.

의암호 유역에서 발생하는 자체생산 유기물 저감방안에 관한 연구 (The Study on Decline Plan of Primary Production Organic Matter of Uiam Lake Basin)

  • 허인량;이건호;함광준;최지용;정의호
    • 한국환경보건학회지
    • /
    • 제30권1호
    • /
    • pp.50-58
    • /
    • 2004
  • The present study was designed to evaluate primary production organic matter in basin of lake around by execution of total maximum daily loading. BOD influent loading of Uiam lake was 2,819 kg/day, which was less then 28.3 percent, total effuluent loading as 3,619 kg/day, in comparision with BOD, total nitrogen influent loading was 4,681 kg/day, which was less then 10.0 percent, total effuluent loading as 5,150 kg/day. But in case of total phosphors influent loading was 73.3 kg/day, which was more then 34.2 percent, total run off loading as 48.3 kg/day. The result of survey reduction plan of primary production organic matter in basin of lake around which objectives of abstract is as follows. First plan was reduction of primary production organic matter by moving the outlet of municipal wastewater treatment center from present place to lake downstream. Secondary plan was improvement by diffusion type of outlet municipal wastewater treatment center. The third plan was reduction of environmental impact by passing and storing of municipal wastewater. Finally plan was decline water surface level which was present hydrouric retention time was reduction from 7.6 day to 6.0 day per meter.

Gas-Filled Intradural Cyst within the Cauda Equine

  • Cho, Hyung-Lea;Lee, Sang-Ho;Kim, Jin-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권3호
    • /
    • pp.182-185
    • /
    • 2011
  • A case of radicular pain that resulted from a gas-filled intradural cyst in an 80-year-old male is described. Temporary improvement of radicular pain was observed after CT-guided aspiration. However, recurrent radicular pain led to surgical treatment. In this report, the authors document the radiologic and intraoperative features of a gas-filled intradural cyst that migrated into the nerve root, and propose an optimal treatment plan based on a review of the literature.

님비와 폐기물처리시설 설치 방향 (The Nimby Syndrome and Basic Plan for Waste Treatment Facilities in 1994)

  • 신현국
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.59-64
    • /
    • 1994
  • In order to democractically resolve the "not-in-my-backyard" (Nimby syndrome) which is widespread in Korea, the policy of the Ministry of Environmnt(MOE) is that the MOE is willing to negotiate with local inhabitants who refuse to allow the establishment of waste treatment facilities, and that such facilities will be safety and effectively constructed and managed. According to this policy, the MOE has developed a basic plan to construct 255 incinerators by the year 2001, and establish 42 sanitary landfill sites and 5 specific waste treatment facilities in 1994.s in 1994.

  • PDF

환자 SET-UP ERROR에 따른 선량분포와 DVH 변화 분석 (The dose distribution and DVH change analysis wing to effect of the patient setup error)

  • 김경태;주상규;안재홍;박영환
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.81-89
    • /
    • 2004
  • 목적 : 방사선 치료에서 환자와 근무자에 의한 setup error등은 치료성적이 결정될 수 있는 중요한 요인이라고 볼 수 있다. 이에 환자와 근무자에 의한 SET-UP ERROR가 환자치료에 미치는 영향에 대하여 비교 분석하고자 한다. 대상 및 방법 : 실험은 human phantom을 이용하여 C-T scan시 Left방향의 Lateral Level을 0mm, 3mm, 5mm, 7mm, 10mm, 15mm, 20mm로 변화시켜 SET-UP ERROR를 유발하였고, 각각에 대하여 C-T scan을 시행하였고, SET-UP ERROR가 유발된 각각의 C-T image를 얻어 RTP장비를 이용하여 임상에서 많이 사용되는 plan을 사용하여 7개의 C-T image에 각각의 plan-대향이문조사plan, Box-4문조사plan, 3Dimension plan-3개를 시행하여 총 21개의 plan을 실시하였다. (CTV+1cm margin, CTV+0.5cm margin, CTV+0.3cm margin = PTV) 이렇게 얻어진 plan을 이용하여 SET-UP ERROR가 유발이 안된 0mm image의 plan 3개와 SET-UP ERROR가 있는 6개 image의 총 18개의 plan을 대향이문조사plan, Box4문조사plan, 3Dimension plan으로 나누어 선량분포와 DVH를 이용하여 비교 분석하였다. 결과 : SET-UP ERROR를 유발시킨 3mm, 5mm, 7mm C-T image에서는 대향이문조사plan을 제외하고는 모든 plan에서 충분히 치료에 영향을 미칠만한 변화가 나타났으며, Box4문조사plan에서는 SET-UP ERROR에 의한 CTV가 Field 밖으로 빠짐으로 선량분포와 DVH가 나빠지는 현상이 나타났다. 결론 : 환자의 움직임, CTV 3차원형태, CTV margin등이 치료에 영향을 미친다. 이러한 영향을 줄이기 위해서는 환자의 긴장감과 움직임을 줄일 수 있는 환자교육과 정확한 환자setup능력이 치료의 승패를 좌우한다고 생각된다. 또한 재현성과 움직임을 줄일 수 있는 accessory 개발과 보급이 중요하다.

  • PDF

하수처리시설의 에너지 자립화 방안 연구 (Study on Energy Independence Plan for Sewage Treatment Plant)

  • 김영준;정철권;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.15-20
    • /
    • 2008
  • The objectives of this study are to analyze the energy independence plan and to propose a suitable sewage treatment plant in Korea. The total amount of electricity consumption for public sewage treatment plant was estimated as 1,182 GWh in 2007. It was estimated that total 16 sewage treatment plants with renewable energy systems produced electricity of 15.2 GWh per year, which could replaced 0.8% of total electricity used for sewage treatment. It was found that domestic sewage treatment plants with power generation plants by digestion gas were installed in 7 places and produced electricity of 13 GWh per year. It was also found that the power generation plants by digestion gas were the most cost-effective for sewage treatment out of the renewable energy systems based on the benefit-cost analysis.

  • PDF

동적 다엽콜리메이터를 이용한 척수의 부분 차폐 기법 (Spinal Cord Partial Block Technique Using Dynamic MLC)

  • 조삼주;이병용;이상욱;안승도;김종훈;권수일;최은경
    • 한국의학물리학회지:의학물리
    • /
    • 제14권1호
    • /
    • pp.8-14
    • /
    • 2003
  • 두경부 및 흥부에서 척수 견딤선량은 방사선 치료 제약 조건중의 하나이다. 이 영역에서 척수 견딤 선량을 임상적으로 허용 가능한 수준으로 유지하면서 표적에 임상적으로 유의한 선량을 전달하는 것은 쉽지 않은 문제이다. 기존의 치료 방법을 적용할 때 따르는 문제를 해결하기 위해 동적 다엽콜리메이터(dynamic multi leaf collimator, dMLC)를 사용한 척수의 부분 차폐 기법(spial cord partial block technique)을 개발하였다. 이 기법은 기존의 3차원 방사선 치료 계획 장치를 사용하여 치료계획을 수립한다. 치료 계획 절차는 표적을 잘 포함 할 수 있는 빔 방향 및 빔 개수를 설정한 후, 척수 등 방사선 민감 장기를 보호하기 위한 부분차폐를 적용하여 최적화된 선량분포를 만들어 낸다. 이 기법의 유용성을 평가하기 위해 동일한 환자에 대해 기존의 치료 계획과 PBT 치료 계획을 수립하여 상호 비교 평가하였다. 평균 선량과 DVH를 치료 계획 평가 인자로 사용하였다. 임상 적용 가능성을 위해 일련의 정도관리를 수행하여 평가하였다. 이 정도관리는 선량 분포 검증에 대한 필름 도시메트리와 단일점 측정으로 구성되어 있다. PBT 치료계획이 기존의 치료계획 보다 좋은 결과를 얻을 수 있었으며, 두경부에서 유용한 치료 기법임을 볼 수 있었다.

  • PDF

Effects of Millimetric Shifts in Breast Cancer Radiotherapy on the Radiation Dose Distribution

  • Sanli, Yusuf Tolga;Cukurcayir, Funda;Abacigil, Fatma
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권3호
    • /
    • pp.1197-1199
    • /
    • 2016
  • Background: This study aimed to facilitate decision-making in cases of breast cancer radiotherapy shifts by simulating millimetric shifts and analyzing their effects on dose distribution. Methods: The study included 30 patients with left side breast cancer who were treated with three dimensional conformal radiotherapy (3D-CRT) in the Radiation Oncology Department in Hatay Public Hospital, between January 2013 and April 2015. A treatment plan shifting at three axes with six different measures was simulated. Results: The biggest difference in values was (+3mm shift) 476cGy, with a 7.7 % change for heart and 25.6% for spinal cord. The shifts in values respectively for CTV min, mean, max were -4.8%, 2.5%, 4%. The differences for lymphatic min, mean, max were 21.3%, 20.3%, -12.2%. Conclusion: The most important thing is not the treatment plan quality, but its practicality. The treatment plan must be practical and its practice must be controlled rigidly.