• Title/Summary/Keyword: Treatment Equipment

검색결과 946건 처리시간 0.028초

공극수 오염이 시멘트 고화처리된 사질토에 미치는 영향 (The Influence of Pore Water Contamination on the Cement Treated Sandy Soil)

  • 유찬
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.144-152
    • /
    • 2003
  • Laboratory experiments were carried out to investigate the influence of pore water contamination on the treatment effect of sandy soil which was solidified by Portland cement. In the experiments, setting time of hydraulic cement that was mixed with contaminated mixing water was measured using Vicat equipment and observed the tendency of setting process with the kind of contaminants, organic or inorganic components. It was shown that organic contaminants of the mixing water affect largely on the initial setting process of hydraulic cement and inorganics, expecially heavy metals, did not affect on the initial setting process, otherwise it was appeared that setting time of the sandy soil that was contaminated with inorganic components was apparently faster than the sandy soil that did not include inorganic components even though organic concentrations was relatively low level (COD=200∼300) in the mixing water. The results of unconfined compression strength test (UCST) were well consistent with the results of Vicat equipment test.

Effect of 8 mW 525 nm LEDs Light Irradiation on the Defect Reduction in the Skin Wound of SD-rat

  • Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권3호
    • /
    • pp.116-119
    • /
    • 2008
  • The purpose of this study is to develop the Photodynamic Therapy Equipment for medical treatment. We developed the equipment which was helpful in palpating wound healing by using 525 nm LEDs. The equipment was assembled with a micro-controller and green color LEDs, and designed to enable us to control light irradiation time, intensity and so on. In this study, the designed device was used to find out how 525 nm LEDs light affected the skin wound of SD-Rat(Sprague-Dawley Rat). We divided the participants into two groups; irradiation group which was irradiated one hour a day for 9 consecutive days, and none irradiation group. The results showed that the study group had lower incidence of inflammation and faster recovery, compared with the control group.

반도체 장비 부품의 Ti/TiN 흡착물 세정 공정 연구

  • 유정주;배규식
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2004년도 춘계학술대회 발표 논문집
    • /
    • pp.92-96
    • /
    • 2004
  • Scales, accumulated on semiconductor equipment parts during device fabrication processes, often lower equipment lifetime and production yields. Thus, many equipments parts have be cleaned regularly. In this study, an attempt to establish an effective process for the removal of scales on the sidewall of collimators in the chamber of sputter is made. The EDX analysis revealed that the scales are composed of Ti and TiN with the colummar structure. It was found that the heat-treatment at 700 for 1 min. after the oxide removal in the HF solution, and then etching in the HNO3 : H2SO4 : H2O =4:2:4 solution for 5.5 hrs at 67 was the most effective process for the scale removal.

  • PDF

Effect of Annealing Heat Treatment to Characteristics of AlDC8 (Al-Si-Cu) Alloy

  • Moon, Kyung Man;Lee, Sung-Yul;Lee, Myeong Hoon;Baek, Tae-Sil;Jeong, Jae-Hyun
    • Corrosion Science and Technology
    • /
    • 제14권6호
    • /
    • pp.296-300
    • /
    • 2015
  • ALDC8 (Al-Si-Cu) alloy has been often corroded with pattern of intergranular corrosion in corrosive environments. Thus, in order to improve its corrosion resistance, the effect of annealing heat treatment to corrosion resistance and hardness was investigated with parameters of heating temperatures such as $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$ and $500^{\circ}C$ for 1hr. The hardness was varied with annealing temperature and slightly decreased with annealing heat treatment. However, the relation between annealing temperature and hardness agreed not well each other. Corrosion potential was shifted to noble direction and corrosion current density was also decreased with increasing annealing temperature. Moreover, both AC impedance at 10 mHz and polarization resistance on the cyclic voltammogram curve were also increased with increasing annealing temperature. Furthermore, intergranular corrosion was somewhat observed in non heat treatment as well as annealing temperatures at $100^{\circ}C$, $200^{\circ}C$ and $300^{\circ}C$, while, intergranular corrosion was not nearly observed at annealing temperature of $400^{\circ}C$, $500^{\circ}C$. Consequently, it is considered that the annealing heat treatment of ALDC8 alloy may be an available method not only to inhibit its intergranular corrosion but also to improve its corrosion resistance.

치료 장비 별 표면 선량 비교평가 (Evaluation of surface dose comparison by treatment equipment)

  • 최은하;윤보름;박병석;안예찬;박명환;박용철
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.31-42
    • /
    • 2022
  • 목 적: 본 연구는 6MV-FFF(Flattening Filter Free) 에너지를 사용하는 Tomotherapy, Halcyon, True-Beam 장비를 이용하여 가상의 표적 용적에 대한 표면 선량 값을 측정, 비교평가하고자 한다. 대상 및 방법: IMRT 팬텀(IBA, Germany)을 이용하였으며 표면 선량 측정의 정확도를 높이기 위해 without bolus, 0.5 cm bolus, 1 cm bolus 총 세 가지 조건으로 전산화 단층촬영을 시행하였다. 가상의 표적 깊이에 치료 계획 용적(Planning Target Volume, PTV)을 설정하고 1회, 200 cGy로 치료 계획을 각각 수립하였다. 표면 선량 측정은 Gafchromic EBT3 필름을 전산화 치료 계획과 동일한 구간에 위치시켜 10회 반복 측정한 뒤 분석하였다. 결 과: 각 장비 별 실험 결과 without bolus, 0.5 cm bolus, 1 cm bolus 순서로 표면 선량 측정값의 평균은 Tomotherapy에서 115.2±2.0 cGy, 194.4±3.3 cGy, 200.7±2.9 cGy로 확인되었고, Halcyon에서 104.7±3.0 cGy, 180.1±10.8 cGy, 187.0±10.1 cGy로 확인되었으며, TrueBeam에서 92.4±3.2 cGy, 148.6±5.7 cGy, 155.8±6.1 cGy로 확인되었다. 세 가지 조건에서 모두 치료 계획 시스템과 동일하게 Tomotherapy, Halcyon, TrueBeam 순으로 높게 측정되었다. 결 론: Tomotherapy와 Halcyon에서 TrueBeam 장비에 비해 표면 선량이 높게 측정되었다. 치료 부위와 치료 목적에 맞춰 장비 별 특성이 고려된다면 치료 효율성의 증가뿐 아니라 환자의 치료 만족도도 높아질 것으로 사료된다.

A Study of the Technical Treatment within an Environmental Appetency for the Ballast Water

  • Nam, Chung-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권8호
    • /
    • pp.1313-1323
    • /
    • 2004
  • In accordance with adoption of new convention for the control of ship's ballast water at the diplomatic conference held in London Feb, 2004, every country has to regulate the ballast water and deposit matters. When this Resolution comes into effect in 2009, all vessels engaged in international voyage must have ballast water control program, ballast water records, equipments which are suitable to the standard of exchange and performance for the ballast water. This study estimates objectively their performances, merits and demerits of the ballast water treatment technique and exchanging techniques for safe operation of ships. It is desirable to design an equipment to control the ballast water using the brush-type vacuum suction nonstop reverse cleaning system to overcome the clogging phenomenon and the direct disc filtering to maximize filtering area for the optimum process considering biological availabilities. It will be expected to protect against marine pollution and to maintain clean sea if it is secured to develop new ballast water treatment techniques. And it will also be expected to cope with the Resolution and each regulation of the developed countries from the ballast water.

Automatic Control on Dosing Coagulant as to Stream Current

  • Oh, Sueg-Young;Byun, Doo-Gyoon;Hwang, Jae-Moon;Song, Hyun-Sung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1318-1321
    • /
    • 2005
  • As recently raw water quality has been polluted as well as its quality has been remarkably varied according to season and region, the precise control of coagulant dosage is being keenly required in water treatment plants. The amount of coagulant is closely related to raw water quality such as turbidity, alkalinity, water temperature, pH, electrical conductivity, etc. Since the optimum quantity of chemicals is not yet finalized, so dosage rate must be decided by using jar test that takes one or two hours. Hereupon, the output signal of stream current and multi-regression on historical data were proposed to be applied to the coagulant dosing control. In consequence of applying the scheme to automatic determination of the dosage rate, it was testified that the determination of dosage rate was very effective in case it is performed as to real-time sensing of water quality and the output signal of stream current.

  • PDF

지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석 (Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

개량형 C95600 청동의 기계적 성질과 미세조직에 미치는 퀜칭 열처리의 영향 (Effect of Quenching Heat-treatment on Mechanical Properties and Microstructure of Modified C95600 Bronze)

  • 이성열;문경만;오재환;신동일
    • 한국해양공학회지
    • /
    • 제25권6호
    • /
    • pp.97-104
    • /
    • 2011
  • Modified C95600 bronze contains Fe component of 0.7 weight percentage besides Cu-7Al-2.5Si composition. The shape of centrifugal cast is a circular pipe with thick wall. Specimens machined from the centrifugal cast were quenched in oil after isothermal holding at a given heat treatment temperature in the range of $700{\sim}900^{\circ}C$. Mechanical properties and structural morphology are depended on the quenching heat treatment temperature regardless of isothermal holding time. Tensile strength or Brinell hardness is increased with increasing heat treatment temperature. The microstructure caused by quenching contains mixing phases of ${\alpha}+{\beta}'+FeSi+{\kappa}$ which martensite of ${\beta}'$ phase has been transformed from ${\beta}$ phase. Effect of isothermal holding temperature on mechanical properties in case of quenching heat treatment attributes to the change of volume fraction of ${\beta}'$ on the structural morphology. Mechanical characteristics of specimen, initially quenched from $850^{\circ}C$, and then tempered at $500^{\circ}C$, does not show an obvious softening indication, because disappearance of ${\beta}'$ during tempering process can be compensated by precipitation of brittle phase ${\gamma}$.

PYROPROCESSING TECHNOLOGY DEVELOPMENT AT KAERI

  • Lee, Han-Soo;Park, Geun-Il;Kang, Kweon-Ho;Hur, Jin-Mok;Kim, Jeong-Guk;Ahn, Do-Hee;Cho, Yung-Zun;Kim, Eung-Ho
    • Nuclear Engineering and Technology
    • /
    • 제43권4호
    • /
    • pp.317-328
    • /
    • 2011
  • Pyroprocessing technology was developed in the beginning for metal fuel treatment in the US in the 1960s. The conventional aqueous process, such as PUREX, is not appropriate for treating metal fuel. Pyroprocessing technology has advantages over the aqueous process: less proliferation risk, treatment of spent fuel with relatively high heat and radioactivity, compact equipment, etc. The addition of an oxide reduction process to the pyroprocessing metal fuel treatment enables handling of oxide spent fuel, which draws a potential option for the management of spent fuel from the PWR. In this context, KAERI has been developing pyroprocessing technology to handle the oxide spent fuel since the 1990s. This paper describes the current status of pyroprocessing technology development at KAERI from the head-end process to the waste treatment. A unit process with various scales has been tested to produce the design data associated with the scale up. A performance test of unit processes integration will be conducted at the PRIDE facility, which will be constructed by early 2012. The PRIDE facility incorporates the unit processes all together in a cell with an Ar environment. The purpose of PRIDE is to test the processes for unit process performance, operability by remote equipment, the integrity of the unit processes, process monitoring, Ar environment system operation, and safeguards related activities. The test of PRIDE will be promising for further pyroprocessing technology development.