• Title/Summary/Keyword: Treatment Equipment

Search Result 943, Processing Time 0.031 seconds

The Management of Chronic Wound with Modified Portable Negative Pressure Therapy (만성 창상의 치료에서 이동식 음압요법의 신고안)

  • Kim, Jee Soo;Yoon, In Mo;Yoo, Jung Seok
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.223-228
    • /
    • 2008
  • Purpose: V.A.C. is a new concept which is closed dressing with negative pressure to promote wound healing. It has been widely used as the treatment of chronic and acute wounds such as pressure sores, burns, stasis ulcers, and other complicated wounds. However It has disadvantages such as high cost and the need of specific equipment. In this article, we described new method to overcome these disadvantages. Methods: We made newly innovated equipment with 50 cc syringe and spring to create negative pressure. From May 2006 to May 2007, we applied it to two patients with chronic wound. Results: The treatment period was 5 weeks for one case and 3 weeks for the other case. Both patients were healed completely without admission and wound healing was accelerated. During follow-ups, there were no complications. The mean cost for single dressing was 9,590 won. Conclusion: Modified portable negative therapy using newly innovated equipment could accelerate wound healing better than conventional dressing. It lowers the number of dressings, saves cost of treatment, and enables treatment as outpatient basis.

A Process for Recycling of Used Steel Can and Automatic Treatment System (스틸 폐캔 再活用방법과 自動化 처리장치)

  • 박형규
    • Resources Recycling
    • /
    • v.9 no.6
    • /
    • pp.53-57
    • /
    • 2000
  • In the present paper, a current technical progress for recycling of used steel can is described. The developed technology was a kind of pre-treatment through an automatic equipment system to increase recycling and melting efficiency of used steel co. The process consisted of several unit processes such as breaking of steel can bale, removing dust, separation of aluminum can, delacquering, and compressing to bale. Also, aluminum powders were recovered as a by-product at the delacquering step. The process was carried out automatically through by use of the developed equipment system. The automatic system could be very available in mass treatment of used steel can.

  • PDF

Effect of the Heat Treatment on the Mechanical Property and Corrosion Resistance of CU - 7Al - 2.5Si Alloy (Cu-7Al-2.5Si 합금의 기계적 및 내식특성에 미치는 열처리 효과)

  • Lee, Syung-Yul;Won, Jong-Pil;Park, Dong-Hyun;Moon, Kyung-Man;Lee, Myeong-Hoon;Jeong, Jin-A;Baek, Tae-Sil
    • Corrosion Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.28-35
    • /
    • 2014
  • Recently, the fuel oil of diesel engines of marine ships has been increasingly changed to heavy oil of low quality as the oil price is getting higher and higher. Therefore, the spiral gear attached at the motor of the oil purifier which plays an important role to purify the heavy oil is also easy to expose at severe environmental condition due to the purification of the heavy oil in higher temperature. Thus, the material of the spiral gear requires a better mechanical strength, wear and corrosion resistance. In this study, the heat treatment(tempering) with various holding time at temperature of $500^{\circ}C$ was carried out to the alloy of Cu-7Al-2.5Si as centrifugal casting, and the properties of both hardness and corrosion resistance with and without heat treatment were investigated with observation of the microstructure and with electrochemical methods, such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram, and a.c. impedance. in natural seawater solution. The ${\alpha}$, ${\beta}^{\prime}$ and ${\gamma}_2$ phases were observed in the material in spite of no heat treatment due to quenching effect of a spin mold. However, their phases, that is, ${\beta}^{\prime}$ and ${\gamma}_2$ phases decreased gradually with increasing the holding time at a constant temperature of $500^{\circ}C$. The hardness more or less decreased with heat treatment, however its corrosion resistance was improved with the heat treatment. Furthermore, the longer holding time, the better corrosion resistance. In addition, when the holding time was 48hrs, its corrosion current density showed the lowest value. The pattern of corroded surface was nearly similar to that of the pitting corrosion, and this morphology was greatly observed in the case of no heat treatment. It is considered that ${\gamma}_2$ phase at the grain boundary was corroded preferentially as an anode. However, the pattern of general corrosion exhibited increasingly due to decreasing the ${\gamma}_2$ phase with heat treatment. Consequently, it is suggested that the corrosion resistance of Cu-7Al-2.5Si alloy can be improved with the heat treatment as a holding time for 48 hrs at $500^{\circ}C$.

Development of a Microcurrent acupuncture point treatment equipment (미세전류 경혈치료기의 개발)

  • Jung, Won-Ki;Kim, Young-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2958-2962
    • /
    • 2010
  • We developed a Microcurrent acupuncture point treatment equipment using micro-controller AVR. This equipment can generate a sine wave, triangle wave, square wave and DC. The frequency range of waves like the sine wave and the triangle wave is 1 - 320 Hz and the output range of DC is $40-200\;{\mu}A$. The duration is controllable between a minute to 30 minutes.

Efficacy and Usability of Patient Isolation Transport Module for CBRN Disaster : A Manikin Simulation Study (특수재난 대응 환자 격리 이송 장비의 효율성 및 편의성 평가: 마네킹시뮬레이션 연구)

  • Kim, Ki-Hong;Hong, Ki-Jeong;Haam, Seung-Hee;Choi, Jin-Woo
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • In Chemical, Biological, Radiological and Nuclear (CBRN) disaster, integrated and optimized equipment package including stretcher, isolation unit, patient monitoring and treatment equipment is essential to achieve proper treatment and prevent secondary contamination. The purpose of this study was to evaluate the efficiency and ease of use of integrated CBRN disaster equipment package for disaster medical response. This study was a randomized crossover study using a manikin simulation for emergency medical technitian (EMT). All participants used the existing devices and prototype of integrated CBRN disaster equipment package alternately. Efficiency was measured by time from vital sign change to detection or treatment application. Ease was use was measured by questionnaires for each patient monitor, stretcher care and isolation unit. 12 EMTs were enrolled. hypoxia-detection time of integrated equipment group was significantly shorter than existing equipment group (4.9 s (3.8-3.9) vs 3.5 s (2.5-3.9), p < 0.05). There was decreasing tendency of ECG change detection and facial mask oxygen supply but no statistical significance was observed. Overall satisfaction of patient monitoring device in integrated equipment group was significantly higher than existing devices (4(3.5-5) vs 3(3-3), p < 0.05). The use of integrated CBRN disaster equipment package shortened the hypoxia detection time and improved usability of vital sign monitor compared to existing devices.

A experimental study about plasma ion treatment to improve hardness of electro-polished surface (전해연마면의 표면경도 향상을 위한 플라즈마 이온질화 처리법에 관한 실험적 연구)

  • Kim, Jin-Beom;Hong, Pil-Gi;Seo, Tae-Il;Son, Chang-Woo
    • Design & Manufacturing
    • /
    • v.13 no.1
    • /
    • pp.13-18
    • /
    • 2019
  • The size and prospects of the domestic semiconductor equipment market are increasing every year. In the case of various parts used inside semiconductor equipments, high durability such as high strength and abrasion resistance is demanded. Particularly, the gases used in semiconductor production processes are toxic. In order to prevent such toxic gas leakage, a precision processing technique and a surface treatment technique for preventing corrosion are required. Electro-polishing is an electro-chemical method of polishing a metal surface to make it smooth and polished. Electro-polishing is mainly used in the finishing process of metal surface. Unlike mechanical polishing, electro-polishing is used in many fields, such as fine chemical etching equipment, since no damaged layer or burr, fine polishing groove and particles are generated. However, in order to withstand the gas used in the semiconductor equipment, the parts must have high corrosion resistance. However, the surface hardness generally become lowered through electro-polishing. Therefore, in this study, surface hardness were experimentally observed before and after electro-polishing. Then, a method of improving hardness by preparing a nitrided layer by plasma ion nitriding treatment.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.

Effect of different concentrations of hypotaurine on melanosis and quality of Pacific white shrimp (Penaeus vannamei) during refrigeration

  • Zhou, Jiaying;Ying, Yubin;Zhou, Yaqi;Li, Gaoshang;Hu, Yaqin
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.4
    • /
    • pp.231-242
    • /
    • 2022
  • Effect of different concentrations of hypotaurine (HTU) on melanosis and quality of shrimps during 10 d storage in ice were studied. During refrigeration, the total plate count and total volatile basic nitrogen of shrimps treated with 20 g/L HTU were the lowest, and the hardness and microstructure were the best. Moreover, the score of melanoses, pH and total bile acid of shrimps treated with 20 g/L HTU were also low. Sensory evaluation showed that HTU treatment could make the shelf life of shrimps 3-4 days longer compared with the control. Based on the above physical and chemical indexes, 20 g/L HTU showed great potential as a safe inhibitor in the treatment of shrimps' melanosis.

Fault Diagnosis of Equipment of Wastewater Treatment Plants by Vibration Signal Analysis Using Time-Series Data Mining

  • Choi, Dae-Won;Bae, Hyeon;Chun, Seung-Pyo;Kim, Sung-Shin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2192-2197
    • /
    • 2005
  • This paper describes how to diagnose SBR plant equipment using time-series data mining. It shows the equipment diagnostics based upon vibration signals that are acquired from each device for process control. Data transform techniques including two data preprocessing skills and data mining methods were employed in the data analysis. The proposed method is not only suitable for SBR equipment, but is also suitable for other industrial devices. The experimental results performed on a lab-scale SBR plant show a good equipment-management performance.

  • PDF

A Study on the Effectiveness of Skin Care Solution System using Non-Invasive Air Technology

  • Park, Do-Young;Yoon, Dong-Gon;Seo, Jung-Gil
    • Journal of Platform Technology
    • /
    • v.10 no.3
    • /
    • pp.3-10
    • /
    • 2022
  • The effectiveness of an innovative skin treatment system that delivers an anti-aging solution deep into the skin without invasiveness and pain using a non-invasive air technology was investigated. In addition, an effective change using a non-invasive technique for delivering a solution for skin improvement was confirmed. The equipment named Cellre Jet is an effective skin care and drug delivery equipment that instantly opens the skin epidermis by using a maximum output pressure of 6 bars and high-pressure purified oxygen of 75-90% purity to deliver various nano-sized vital substances deep into the skin, and it uses the method of precisely controlling the equipment through an 8-inch digital touch display to accurately dispense the prescribed dosage. In this study, changes in skin condition were analyzed using this equipment and nano ampoules on subjects with actual skin problems through a related comparison and effectiveness judgment program. Through this study, skin care and drug delivery are possible, which will contribute to verifying the effectiveness of this non-invasive drug delivery equipment in the future, and is expected to establish the systematic effect in observing and studying changes in the skin.