• 제목/요약/키워드: Treatment Equipment

검색결과 942건 처리시간 0.034초

충주호 상류지역의 유황별 장래수질예측 (Water quality forecasting on upstream of chungju lake by flow duration)

  • 이원호;한양수;연인성;조용진
    • 환경위생공학
    • /
    • 제17권4호
    • /
    • pp.1-9
    • /
    • 2002
  • In order to define about concern with discharge and water-quality, it is calculated drought flow, low flow, normal flow and wet flow in Chungju watershed from flow duration analysis. Water quality modeling study is performed for forecasting at upstream of Chungju lake. It is devided method of modeling into before and after the equipment of environmental treatment institution. And it is estimated the change of water quality. Before the equipment of environmental treatment, BOD concentration is increased from 23000 to 2006 years at all site and decrease on 2012 years. The rate of increasing BOD concentration is showed height between 2000 years and 2003 years most of all site. And after the equipment of environmental treatment, it is showed first grade of BOD water quality in most of sample site beside Jucheon river. The result of water quality modeling using drought flow showed that a lot of pollution occurred. And water quality using wet flow is good, so much discharge make more improve water quality than little discharge.

Microwave and RF Heating for Medical Application under Noninvasive Temperature Measurement Using Magnetic Resonance

  • Nikawa, Yoshio;Ishikawa, Akira
    • Journal of electromagnetic engineering and science
    • /
    • 제10권4호
    • /
    • pp.244-249
    • /
    • 2010
  • Recent development of magnetic resonance imaging (MRI) equipment enables interventional radiology (IVR) as diagnosis and treatment under MRI usage. In this paper, a new methodology for magnetic resonance (MR) scanner to apply not only diagnostic equipment but for treatment one is discussed. The temperature measuring procedure under MR is to measure phase shift of $T_1$, which is the longitudinal relaxation time of proton, for the position inside a sample material with the application of pulsed RF for heating inside the sample as artificial dielectrics. The result shows the possibility to apply MR as temperature measuring equipment and as a heating equipment for applying such as hyperthermia heating modality.

다기능 복합관절 연속수동운동 의료기기 설계 (Design of Multifunctional Compound Joint Medical Equipment for Continuous Passive Motion)

  • 이강원;양오;이창호
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.126-131
    • /
    • 2022
  • The number of joint disease patients is increasing every year. Currently, the most CPM(Continuous Passive Motion) equipment uses expensive imported equipment, and one CPM equipment is designed to be used only in one joint, medical personnel or hospitals who are the main users of the medical equipment need to have several types of CPMs for joint rehabilitation. To solve this problem, this paper designed a multifunctional joint medical equipment that enables rehabilitation of knee, shoulder, and elbow joints in one CPM equipment and includes general, intensive, and adaptive exercise functions for effective treatment according to the patient's condition. The patient's condition was diagnosed using a load cell and a current sensor. In this paper, effective rehabilitation methods were presented and high reliability and precision of medical equipment was confirmed through experiments using potentiometer, encoder, and PI controller.

저온 플라즈마를 이용한 피부치료기 개발에 관한 연구 (Development of the Skin Treatment Unit using Low Temperature Plasma)

  • 송광현;고윤석;이우철
    • 한국전자통신학회논문지
    • /
    • 제9권12호
    • /
    • pp.1427-1434
    • /
    • 2014
  • 의료기기중 체외에서 인체로 물리적 에너지를 가하거나 그 의료기기의 에너지를 이용하여 인체의 화학적 변화를 이용하여 치료를 하는 것은 고도의 신뢰성과 안정성이 요구된다. 특히 인체의 모든 부분 중 가장 외부로 노출되어있는 피부에 대한 치료는 매우 중요 하다고 할 것이다. 이러한 관점에서 보았을 때 피부 치료 시 발생 할 수 있는 모든 위험 요소를 줄이고 치료의 효과를 극대화 할 수 있는 장비의 개발은 높은 치료 효과와 안전성 확보를 위하여 반드시 필요하다고 할 것이다.

석탄광의 산성갱내배수 처리.이용.제어에 관한 연구 -한국형 특수갱배수 정화장치 시작품 현지적용실험- (Study on the Treatment, Utilization and Control of the Acid Mine Drainage for Colliery - An on-site test on the Applicability of a Korean-type Prototype for Mine Drainage Purification-)

  • 이춘택
    • 기술사
    • /
    • 제19권4호
    • /
    • pp.11-21
    • /
    • 1986
  • Mine drainage from coal mines is mostly acidic, polluted and/or contaminated, even if its quantity has increased substantially during recent days. This causes two kinds of problems arising at mining districts; one is the environmental disruption and the other is insufficient water supply for living, employee's bathing and industrial purposes. In order to mitigate the aforementioned problems, a specific equipment of Korea type for mine drainage purification has been developed and its prototype manufactured, followed by its applicability tests implemented at mine site. The results of the tests indicates that the new equipment developed is much lower than and economical compared to, other existing neutralization facilities at home and abroad in capital investment at installation stage, the consumption of neutralizing chemicals at operation stage and the requirements of installation site. Whangji area where the prototype water treatment equipment is installed has been sustaining a short supply of usable water, especially in dry seasons and supplementing about 40㎥ of water brought from a location farther than 4km in distance to meet water requirements. The prototype water treatment equipment is however considered capable of providing compressor cooling water in sufficient amount from winter season In the future.

  • PDF

소구경 탄약 분해기술 및 장비개발 (Development of dissolvable technique and equipment for small caliver ammunition)

  • 구경화;이재화;김석;정현수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1916-1920
    • /
    • 2003
  • By development of dissolvable technique and equipment for warhead, empty cartridge and ammunition in small caliver, pollution of environment and waste of resources problems brought by existing incinerative abrogation can be fundamentally prevented. In addition, Automatic high-speed mechanically dissolving technique using indexing equipment developed in this study makes possible curtailment of manpower and recycling treatment of recources.

  • PDF

Low Temperature Thermal Desorption (LTTD) Treatment of Contaminated Soil

  • Alistair Montgomery;Joo, Wan-Ho;Shin, Won-Sik
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.44-52
    • /
    • 2002
  • Low temperature thermal desorption (LTTD) has become one of the cornerstone technologies used for the treatment of contaminated soils and sediments in the United States. LTTD technology was first used in the mid-1980s for soil treatment on sites managed under the Comprehensive Environmental Respones, Compensation and Liability Act (CERCLA) or Superfund. Implementation was facilitated by CERCLA regulations that require only that spplicable regulations shall be met thus avoiding the need for protracted and expensive permit applications for thermal treatment equipment. The initial equipment designs used typically came from technology transfer sources. Asphalt manufacturing plants were converted to direct-fired LTTD systems, and conventional calciners were adapted for use as indirect-fired LTTD systems. Other innovative designs included hot sand recycle technology (initially developed for synfuels production from tar sand and oil shale), recycle sweep gas, travelling belts and batch-charged vacuum chambers, among others. These systems were used to treat soil contaminated with total petroleum hydrocarbons (TPH), polycyclic aromatic hydrocarbons (PAHs), pesticides, polychlorinated biphenyls (PCBs) and dioxin with varying degrees of success. Ultimately, performance and cost considerations established the suite of systems that are used for LTTD soil treatment applications today. This paper briefly reviews the develpoment of LTTD systems and summarizes the design, performance and cost characteristics of the equipment in use today. Designs reviewed include continuous feed direct-fired and indirect-fired equipment, batch feed systems and in-situ equipment. Performance is compared in terms of before-and-after contaminant levels in the soil and permissible emissions levels in the stack gas vented to the atmosphere. The review of air emissions standards includes a review of regulations in the U.S. and the European Union (EU). Key cost centers for the mobilization and operation of LTTD equipment are identified and compared for the different types of LTTD systems in use today. A work chart is provided for the selection of the optmum LTTD system for site-specific applications. LTTD technology continues to be a cornerstone technology for soil treatment in the U.S. and elsewhere. Examples of leading-edge LTTD technologies developed in the U.S. that are now being delivered locally in global projects are described.

  • PDF

치료방사선과 영역의 적정관리 (Quality Assurance for Radiation Oncology)

  • 김귀언
    • 한국의료질향상학회지
    • /
    • 제2권1호
    • /
    • pp.110-117
    • /
    • 1995
  • The Comprehensive quality assurance for radiation oncology provides an overall organizational structures, responsibilities, procedures, processes and resources for assuring the quality of patient management by radiation treatment. Superior performance of modern radiotherapy equipment will be essential part of quality assurance in radiation oncology, which high degree of accuracy and consistency should be maintained under the optimal quality assurance program. Besides quality control of all radiation equipment, this review also emphasizes quality assurance of clinical aspect such as adequacy of the medical decision-making which eventually leads to the treatment prescription, accuracy of treatment procedure from treatment preparation to radiation delivery, and the significance of assessment of treatment outcomes with structure and process.

  • PDF

동적시간와핑을 이용한 연속회분식 반응기의 장비고장 감지 (Detection of Equipment Faults at Sequencing Batch Reactor Using Dynamic Time Warping)

  • 김예진
    • 한국환경과학회지
    • /
    • 제25권4호
    • /
    • pp.525-534
    • /
    • 2016
  • The biological wastewater treatment plant, which uses microbial community to remove organic matter and nutrients in wastewater, is known as its nonlinear behavior and uncertainty to operate. Therefore, operation of the biological wastewater treatment process much depends on observation and knowledge of operators. The manual inspection of human operators is essential to manage the process properly, however, it is impossible to detect a fault promptly so that the process can be exposed to improper condition not securing safe effluent quality. Among various process faults, equipment malfunction is critical to maintain normal operational state. To detect equipment faults automatically, the dynamic time warping was tested using on-line oxidation-reduction potential (ORP) and dissolved oxygen (DO) profiles in a sequencing batch reactor (SBR), which is a type of wastewater treatment process. After one cycle profiles of ORP and DO were measured and stored, they were warped to the template profiles which were prepared already and the distance result, accumulated distance (D) values were calculated. If the D values were increased significantly, some kinds of faults could be detected and an alarm could be sent to the operator. By this way, it seems to be possible to make an early detecting of process faults.